Reverse cycle heating in very cold weather: rated capacity against real output
Why a reverse cycle unit gives less heat as the outdoor air gets colder, what the rated figure leaves out, and a checklist of model data to ask for.
Last updated
A reverse cycle air conditioner's heating capacity is rated with the outdoor air at 7°C. It draws its heat from that outdoor air, so as the air gets colder it delivers less, and near freezing it also pauses now and then to clear frost from its outdoor coil. On a frosty morning most units deliver less heat over an hour than the rated figure suggests, once the pauses for defrost are counted. How far under depends on the model: some hold their output in the cold much better than others. For a cold site, ask for the model's heating output at your winter design temperature, from the maker's data, and size on that.
How to use this guide
Step 1: Know what the rating covers
The test points behind the figure, and what they leave out.
Go to The rated figureStep 2: Find your winter
How many cold mornings your area gets, from the Bureau's records.
Go to Your winter
What does the rated heating capacity cover?
The Zoned Energy Rating Label (opens in a new tab) gives the rated figure and a second heating figure at 2°C outside. Below that, the label says nothing, and the maker's own documents are the place to look.
| Figure | What it tells you | What it leaves out |
|---|---|---|
| Rated heating capacity | Output with 7°C outside and 20°C inside. | Every morning colder than 7°C. |
| Heating capacity at 2°C, on the label | Output at the label's cold test point. A unit that can run beyond its rated load is tested here at that higher load, so this figure can be higher or lower than the 7°C figure. Compare it between models, not against the 7°C figure on the same label. | Mornings below 2°C. Ducted and multi-split systems do not have to carry the label. |
| The maker's capacity table | Output across a range of outdoor temperatures, for the exact indoor and outdoor units. | Nothing you need, if it covers your winter design temperature. Ask for it. |
| The operating range | The coldest outdoor air the unit is made to heat in. For current wall and ducted models of several makers it is about minus 15°C, and some go to minus 20°C. | How much heat the unit gives there. Running at a temperature is not the same as delivering its rated heat at it. The specification for your model gives its own limit. |
| Heating stars for your zone | Seasonal efficiency over a year in your climate zone, which allows for defrost and part-load running. | Output on the coldest mornings. |
Why does heating output fall in very cold weather?
A reverse cycle unit is a heat pump. It does not make heat, it moves it: in heating it takes heat from the outdoor air and brings it inside. The colder the outdoor air, the less heat there is to take, so its output falls as the temperature drops.
Frost adds to it. In cold, damp weather ice builds on the outdoor coil, and the unit stops heating for a few minutes at a time, up to about ten or twelve depending on the model, to clear it. The heat delivered over an hour on a frosty morning is lower again than the output while it runs. The guide to frost, water and defrost during reverse cycle heating covers what is normal.
One maker's selection table for a ducted unit rated at 12.6 kW of heating shows the pattern. With 20°C inside and the heat lost to defrost allowed for, it delivers about 12.6 kW with the outdoor air at 6°C, 10.6 kW at 2°C, 9.9 kW at 0°C and 7.9 kW at minus 10°C. The table reads the outdoor air as a wet bulb temperature, which in damp winter air sits about a degree below the ordinary reading. At minus 10°C that unit gives a little over 60 percent of the heat it gives at 6°C. Another model will differ, which is why the table for your model decides.
That table lists two heating figures at each temperature. The lower one allows for the heat lost to defrost, and it is the one that matches the heat a room receives over an hour on a frosty morning. Ask the designer which figure the design used at your winter design temperature.
Units built for heating hold their output better in the cold. They usually have a larger outdoor coil, an inverter compressor that can turn down low, defrost controls tuned to clear ice quickly, a refrigerant circuit designed for low outdoor temperatures, and published figures showing how much output they keep below 2°C. A model without published figures for your temperatures has not shown that it can.
How cold does your winter get?
Set the label's test points beside your own climate. The Bureau of Meteorology's records for two stations in our area show how differently they compare.
| Station | Average July minimum | Mornings at or below 2°C a year | Mornings at or below 0°C a year | Lowest in the station's record |
|---|---|---|---|---|
| Bairnsdale Airport, 49 m above sea level, 46 years of records since 1943 | 4.0°C | About 27 | About 7 | Minus 5.4°C |
| Omeo, 690 m above sea level, records 2004 to 2026 | 0.8°C | About 100 | About 56 | Minus 7.6°C |
The figures are from the Bureau's climate statistics for Bairnsdale Airport (opens in a new tab) and Omeo (opens in a new tab). Both spend most winter mornings below the 7°C rating point. Omeo spends about a hundred mornings a year at or below the label's 2°C point, so a heating design there has to work from the colder figures, not the rated one.
- Find your own station. The Bureau's climate statistics give the same table for stations across Victoria. Open the full table for the station nearest you and note the mornings at or below 0°C and the lowest temperature.
- Allow for your site. A house higher than the station, more exposed to wind, or in a hollow where cold air settles can be colder than the station's figures. Tell the assessor.
- Know what the design temperature is. An installer usually sizes heating for a winter temperature that the outdoor air drops below in only about 1 percent of the hours of a typical year, not the coldest morning on record. On the coldest few mornings a correctly sized system can fall a little behind.
- Find your label zone. The Energy Rating Calculator tells you which of the label's three climate zones to use when you compare heating stars.
Choosing a system when heating matters more than cooling
Where heating is the main job, choose on heating. Ask for the heating load from the calculation, then for each model its output at your winter design temperature. For efficiency, the maker's sheet lists a heating seasonal performance factor (HSPF) for each of the label's three climate zones, and the label shows heating stars for each. Higher is better on both, and the cold zone usually scores lowest. Compare your own zone's heating figures between models of the same type, and leave the cooling figures aside. The guide to heating capacity and cooling capacity on a quote explains the two ratings.
Do not make up for a weak model by buying a bigger one. A unit sized up to cover the coldest mornings spends most of the year at the very bottom of its range, and cycles on and off in mild weather and in summer. A model that holds its output in the cold, sized for the load, usually does better on both counts. The guide to sizing a home air conditioner explains how the load is set.
Where a unit cannot keep up on the coldest mornings, the usual answer is another heater used alongside it. Where the unit holds a flammable refrigerant, that heater should be one that is compatible with it, so ask the installer which kind suits. A design should say whether it counts on one.
Heating an alpine holiday house or a place used now and then
A house that sits empty and cold between visits asks more of a heating system than one lived in every day. The walls, floors and furniture have to warm as well as the air. Raise these with the installer:
- Warm-up time. Ask how long the design takes to bring the main rooms up to temperature from cold on a winter evening at the design temperature. That answer is part of the sizing.
- Starting before you arrive. A controller you can reach from your phone lets the heating start before you get there. Check whether the quote includes it, and that the house has a connection it can use. The guide to holiday and short-stay controls covers the settings.
- The outdoor unit in frost and snow. Ask where it will stand so that frost and drifting snow keep clear of it, and where its defrost water will go so it does not freeze on a path.
- Backup. Decide what keeps the house warm on a morning colder than the design allows for, or during a power cut: a wood heater the house already has, or something else. Write it down so the design does not assume more of the system than it can give.
Cold-weather heating checklist
Getting heating sized for a cold site
We work out the load for each room and look at the site before we quote. For the high country we specify systems with low-temperature heating capability and size them for the cold mornings. Our service area takes in the high country around Omeo, Swifts Creek, Benambra and Ensay, so tell us where the house is, how high, and how it is used. Our air conditioning page explains how to ask for a quote, and our ducted heating and cooling page covers whole-house heating.
Sources (15)
Checked on 20 November 2026
- AIRAH: Residential Air Conditioning Best Practice Guide (Victoria), second edition 2026 (opens in a new tab)
- Energy Rating: understand the Zoned Energy Rating Label (opens in a new tab)
- Bureau of Meteorology: climate statistics for Omeo (083090) (opens in a new tab)
- Bureau of Meteorology: climate statistics for Bairnsdale Airport (085279) (opens in a new tab)
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019 (opens in a new tab)
- ActronAir: Advance ducted catalogue, version 13 (opens in a new tab)
- ActronAir: Advance R-32 ducted catalogue, version 6 (definitions of total and integrated heating capacity) (opens in a new tab)
- Daikin Australia: split systems brochure, September 2026 (opens in a new tab)
- Daikin Australia: Alira X operation manual (opens in a new tab)
- Mitsubishi Electric Australia: MSZ-AP operating instructions (opens in a new tab)
- Mitsubishi Electric Australia: the defrost cycle (opens in a new tab)
- Mitsubishi Electric Australia: ducted air conditioning brochure, September 2026 (opens in a new tab)
- Panasonic Australia: air conditioning buyers guide (opens in a new tab)
- US Department of Energy, Building America: low-temperature air source heat pump report, 2013 (opens in a new tab)
- ABL Refrigeration: air conditioning services (opens in a new tab) ABL's own page.
Related pages
- Heating capacity versus cooling capacity on a quote
Read the two output ratings and the test conditions behind them.
- Outdoor frost, water and defrost during reverse-cycle heating
What normal defrost looks like on a cold morning.
- Ducted heating and cooling in Bairnsdale and East Gippsland
Whole-house heating, and how it copes with a Gippsland winter.
Heating a house at a cold site?
Send ABL your checklist with an enquiry, or call and talk it through.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.