Heating capacity and cooling capacity on an air conditioner quote: what each means
Why an air conditioner has a heating and a cooling capacity, the conditions each is rated at, how to read them beside the input, and a sheet for your quotes.
Last updated
An air conditioner has two output ratings because it is tested twice: for cooling with 35°C outside and 27°C inside, and for heating with 7°C outside and 20°C inside. On most wall split systems the heating figure is the higher of the two, but not on every unit, so read both. Neither is the electricity the unit uses: that is the input, a much smaller number. Compare cooling with cooling and heating with heating, at the same test conditions, and size on the one your house needs most.
How to use this guide
Step 1: Read the two ratings
What each figure measures, and the conditions behind it.
Go to Two ratingsStep 2: Decide which one sizes it
Heating, cooling or both, at your conditions.
Go to Which one sizes itStep 3: Line up the quotes
Put each quote's figures side by side and flag what does not match.
Go to the record
Why does an air conditioner have two capacity figures?
Capacity is output: how much heat a unit moves into a room in heating, or out of it in cooling, measured in kilowatts (kW). It changes with the temperature outside and inside, so it means something only at stated conditions. Makers rate every model at the same standard test points, which is what lets you compare one model with another.
| Rating | Outside | Inside |
|---|---|---|
| Cooling capacity | 35°C | 27°C, at a set humidity |
| Heating capacity | 7°C | 20°C |
| Heating capacity on the label's cold point | 2°C | 20°C |
The Zoned Energy Rating Label (opens in a new tab) shows cooling capacity at 35°C and heating capacity at both 7°C and 2°C, as at November 2026. Ducted and multi-split systems do not have to carry it, so for those ask for the maker's specification sheet.
In the current wall split ranges of two makers, every model's heating figure is equal to or higher than its cooling figure: a 7.1 kW cooling model rates at 8.0 kW for heating in both. That does not hold for every unit. One maker's ducted unit is rated at 13.25 kW for cooling and 12.6 kW for heating. Read both figures for the model you are offered.
The two ratings answer different questions. The cooling figure says how much heat the unit can take out of the room on a hot afternoon. The heating figure says how much it can put in on a cool morning, and only at 7°C outside: on a colder morning it gives less. The guide to heating output in very cold weather covers that.
An example specification, annotated
These are the published figures for one maker's current 7.1 kW wall-mounted split system, as at October 2026. Another model, even of the same nominal size, has its own figures.
| Line on the sheet | Figure | What it tells you |
|---|---|---|
| Cooling capacity, minimum, rated and maximum | 2.0, 7.1 and 8.7 kW | The rated 7.1 kW is the output at the cooling test point. It is also the figure this unit is described by. The minimum and maximum are the range the inverter can run across. |
| Cooling total input | 0.43, 2.01 and 3.03 kW | The electricity it draws, not what it delivers. At the rated point it gives about 3.5 kW of cooling for each kW it draws. |
| Heating capacity, minimum, rated and maximum | 2.2, 8.0 and 9.9 kW | The rated 8.0 kW is the output with 7°C outside and 20°C inside. It is higher than the cooling figure on the same unit. |
| Heating total input | 0.42, 2.09 and 3.25 kW | At the rated point it gives about 3.8 kW of heat for each kW it draws. |
| Star ratings for the hot, average and cold zones | Cooling 3.5, 3 and 3.5. Heating 3, 2.5 and 2. | Seasonal efficiency for each climate zone, cooling and heating separately. Compare stars only between models of a similar size. |
| The rating conditions, in the footnotes | Cooling and heating test points of the Australian and New Zealand standard | The figures are at the standard test points in the table above. Check that another quote's figures are too. |
What the sheet does not show is as useful as what it does. It gives no heating output colder than 7°C, so for a cold site ask for the maker's capacity table. Dividing output by input gives an efficiency at the test point only. What you pay over a year depends on the seasonal figures and your own use: the guide to kW output and electricity usage works through it.
Which figure should the size follow?
A load calculation gives a cooling load for the hottest weather the design allows for and a heating load for the coldest. The unit has to meet both at those conditions, and one of them usually decides the size. The guide to sizing a home air conditioner explains how the loads are worked out.
- When heating is the main job, as it is in many Victorian homes, size on the heating load at your winter conditions. Look at the heating figures and the heating stars for your zone, and ask for the maker's heating output at your winter design temperature rather than the rated figure alone.
- When cooling is the main job, size on the cooling load, and look at the cooling figures and the cooling stars.
- When both matter, the unit has to cover the larger of the two. If heating sets a size bigger than the cooling load needs, check how low the unit can turn down, so it can still run gently in summer. The guide to oversized air conditioning explains why that matters.
Ask each installer which season set the size, and at what conditions. A bigger heating number on one quote is not a better quote until you know what it was rated at and what the house needs. The Energy Rating Calculator tells you which of the label's three climate zones applies to you, and the guide to choosing an inverter replacement covers the seasonal efficiency figures.
What if the quotes give different kinds of figure?
A quote should state both the heating and the cooling capacity. These are the mismatches to flag before you compare prices:
| What you see | What to ask for |
|---|---|
| Only one capacity is given | The other one, from the maker's sheet for the exact indoor and outdoor units. |
| A size class, such as "a 7 kW unit", against rated figures | The rated cooling and heating capacity of the model, so both quotes are in the same terms. |
| The maximum on one quote, the rated figure on the other | The rated figure from both. The maximum is not what a unit is sized by. |
| Heating at different outdoor temperatures | Both at 7°C, and both at 2°C where the label gives it, or both at your winter design temperature. Compare the 2°C figures with each other, not with the 7°C figures. |
| A ducted or multi-split system with no label | The maker's specification sheet, with its test conditions in the footnotes. |
| The electrical input written as if it were output | Both figures, labelled. Input is the smaller number. |
When the figures line up, the guide to comparing air conditioning installation quotes covers everything else a quote should state.
Capacity comparison sheet
Getting a quote that states both
We work out the load for each room, so the system is sized for East Gippsland's climate, and we look at the site before we quote. Ask which season set the size, and for the figures behind it. Our air conditioning page explains how to ask for a quote.
Sources (10)
Checked on 20 November 2026
- AIRAH: Residential Air Conditioning Best Practice Guide (Victoria), second edition 2026 (opens in a new tab)
- Energy Rating: understand the Zoned Energy Rating Label (opens in a new tab)
- Energy Rating: heating and cooling (opens in a new tab)
- Victorian Government: choosing the right reverse cycle air conditioner (opens in a new tab)
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019 (opens in a new tab)
- Mitsubishi Electric Australia: MSZ-AP series flyer, October 2026 (opens in a new tab)
- Daikin Australia: split systems brochure, September 2026 (opens in a new tab)
- ActronAir: Advance ducted catalogue, version 13 (opens in a new tab)
- Solar Victoria: home heating and cooling upgrades buyers guide (opens in a new tab)
- ABL Refrigeration: air conditioning services (opens in a new tab) ABL's own page.
Related pages
- Rated capacity versus output in very cold weather
Why heating output falls below the rated figure on a cold morning.
- Sizing a home air conditioner: room boundaries, loads and quote assumptions
How the heating and cooling loads are worked out.
- Air conditioner kW output vs electricity usage: working out the running cost
Turn the input figures into a yearly running cost.