One zone of a ducted air conditioning system not cooling: map it before you call

Why one zone of a ducted air conditioner is not cooling, what you can safely check, and a room-by-room comfort map to fill in before you call.

Last updated

When one zone of a ducted air conditioner is not cooling, the usual reasons are a zone that has already reached its set temperature, a zone or damper that is not opening, a dirty return air filter, or more zones running than the system was designed for.

How to use this guide

  1. Step 1: Check the simple things

    Zone settings, doors, windows and what is in front of the grilles.

    Go to Simple checks
  2. Step 2: Map the rooms

    Fill in a line for the warm room and for two rooms that are fine.

    Go to the record
  3. Step 3: Call

    Read the map out, or paste it into your enquiry.

    Call (03) 5153 2650

Why is one zone of a ducted air conditioner not cooling?

A zone that seems not to be working has often reached its set temperature. Where the zone has its own sensor, the system stops sending it air once it gets there. Beyond that, the usual causes are:

Usual causes of one zone not cooling
Possible causeWho deals with it
The zone has reached its set temperatureNobody. A zone with its own sensor closes when the room is at temperature. That is normal.
A setting: a timer on the wall control, or the indoor fan set lowYou, at the controller.
A dirty return air filterYou, the way your manual shows.
More heat than the system was designed forYou, for open windows and doors and for zones left on in rooms nobody is using. A site assessment, for the design.
A zone motor or damper that is not opening, or a fault in its control cableThe installer or a technician.
A restriction in the ductworkThe installer or a technician. Duct sizes, tight bends and the size of the return air grille all count.
Something blocking the air at the outdoor unitYou, for anything stacked or growing against it.

The first four you can see from the controller and the rooms. The last three are why the map matters: it shows a technician which rooms are short of air and when.

What can I check before I map the house?

These are things you can see from the controller and the rooms.

What to check, and what to write down
Look atCheck, then write down
The zoneCheck the zone for the warm room is switched on at the controller. Write down which zones were on and which were off.
Mode and set temperatureCheck they are set where you expect. Write down both, and the setting of the zone itself if it has one.
Doors and windowsCheck whether the door and windows of the warm room were open or shut. Write down which, for each room on your map.
The grilles in the roomCheck that furniture, curtains or stored things are not in front of them. Write down anything you moved, and whether it helped.
The zone's own temperatureIf the zone has its own sensor or set temperature, check what it is set to against how the room feels. A zone at its temperature gets little or no air. Write down both.
Zones nobody is usingTurn unused zones off when cooling is short. Write down which zones you turned off, and whether the warm room improved.
The fan settingA low indoor fan setting cuts what the system can deliver. Write down the fan setting.
The return air filterIt is usually in the return air grille, often in a hallway, and needs cleaning like any other filter. Clean it the way your manual shows. Write down when it was last cleaned.

Do not adjust a damper, re-aim or tape a grille, or go into the roof space.

How do I map a ducted system room by room?

  1. Pick a time when the problem shows, after the system has been running for a while.
  2. Start with the warm room. Note its zone setting, whether the door is open, how strong the air is at the grille and how the room feels.
  3. Do the same in two rooms that are fine, so there is something to compare with.
  4. Note which other zones were on, the time of day and the weather.
  5. If you can, repeat it once at a different time of day.

Use your hand for the airflow and your own judgement for comfort. A thermometer moved from room to room is a bonus, not a requirement.

Room-by-room comfort map

Ducted comfort map

Fill in one part for the warm room and one for each of two rooms that are fine, then copy it or print it.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

Your system

How the zones are controlled

The warm room

Warm room: door
Warm room: airflow at the grille

A room that is fine

Second room: door
Second room: airflow at the grille

Another room that is fine

Third room: door
Third room: airflow at the grille

Conditions and history

Why are rooms on the same air conditioning at different temperatures?

Usually for one of the reasons in the table above, and often more than one. Your map separates the things you can see from the things only an assessment can find. Sun on one side of the house, an open door or a zone left off will show on the map. The ducts, the dampers and the unit itself are for the technician.

Mark whether the difference is new or the room has been like this since the system went in. Those are two different conversations.

What was the system designed to do?

Ducted systems are not all alike. Some are slim units made for compact ceiling spaces, and some are made for longer duct layouts. So the same complaint can mean different things on different systems, and the model number matters.

Design matters as much as the model. Some ducted systems are designed to heat or cool only part of the house at any one time. On a system like that, running every zone together leaves each with less, and that is how it was built and not a fault.

A day hotter than the system was designed for has the same effect. On a day like that, start the system early.

Before the visit, find what you have on paper:

  • the installation quote or handover papers, with the model and the number of zones
  • the controller or zone controller manual, and what it says about running zones together
  • anything added since: a room, a zone, or a change to the ducts

What will a technician usually do?

For a zone that gets no air whatever the settings, we check:

  • whether the zone motor responds when the zone is switched on and off
  • if the motor works, whether anything restricts the ductwork to that zone
  • the zone control cable and the zone port on the main control module
  • the zone damper itself

Where the airflow is uneven and nothing has failed, the fix is usually to balance the air between outlets or to review the duct design. That is why a map of several rooms is worth more than a note about one.

How urgent is one warm zone?

What the signs mean for timing
What you noticeWhat to do
Water or a stain at a ceiling outlet, a burning smell, or a breaker that tripsStop using it now and call. The warning at the top of this page applies. The guide to a split system leaking water inside covers ducted outlets.
A zone that gets no air whatever the settingsBook a visit. A zone that gets no heating or cooling whatever its settings usually has a fault in its motor, damper or controls.
A room that lags on the hottest afternoons and is fine otherwiseMap it on a hot day and a mild one, then ask for an assessment. On a day hotter than the system was designed for, start it early.

What should I ask for?

Ask for an assessment of the existing system, and hand over the map and the papers. Ask what was found before you accept that the house needs a larger unit or another zone. For new or replacement ducted work, see the ducted air conditioning page. If a grille whistles as well, the guide to air conditioner rattling and vibration noise has a sound log.

We repair and service air conditioners for homes and businesses in Bairnsdale and East Gippsland. Our air conditioning repairs page explains how to book.