Skip to the content

Air conditioner burning smell or tripping breaker: what to do

What to do when an air conditioner smells of burning or trips its circuit breaker: switch it off, leave it off, record what you noticed and call.

Last updated

A burning smell from an air conditioner, or one that trips its circuit breaker, means something in the unit or its power supply is overheating or has failed. It is a reason to stop at once, because running on can end in a fire or an electric shock. This guide covers the first few minutes, the usual causes, what is safe to write down, and who to call.

Once it is switched off

  1. Step 1: Leave it off

    Do not turn it back on to check it, and leave a tripped breaker as it is.

    Go to Danger or comfort
  2. Step 2: Write it down

    Record what you already noticed. Do not go back to the unit to find out more.

    Go to the record
  3. Step 3: Call

    Read the record out, and say what tripped or what you smelt.

    Call (03) 5153 2650

Is it a danger sign or a comfort problem?

A danger sign means stop now. A comfort problem means the unit is unpleasant or not doing its job, and it has its own guide, which says what to record before you call.

Danger signs: stop using the air conditioner
What you noticeWhat to do
A burnt or burning smellLeave it off and call.
Its breaker or safety switch trips, or its fuse blowsLeave it off, leave the breaker as it is, and call.
Smoke, sparks or flamesGet everyone out and call Triple Zero (000) (opens in a new tab), Australia's emergency number for life threatening or time critical situations.
A tingle or a shock from the unit, another appliance or a tapDo not touch it again. Energy Safe Victoria says to call your electricity company immediately (opens in a new tab), and that a licensed electrician must check the property's wiring.
An abnormal noise from the indoor unitLeave it off and call. The guide to air conditioner rattling and vibration noise covers what to record about a sound.
The on/off button does nothingSwitch it off at its power point or breaker if that is dry and within easy reach, then call. See the guide to an air conditioner that will not turn on.
Comfort problems: where to go next
What you noticeWhere to go next
A musty or stale smell when it startsUsually dust or mould on the filters or inside the indoor unit. See the guide to a musty smell when the air conditioner starts.
It runs, but the room is not comfortableSee the guide to an air conditioner that is not cooling or heating.

If you cannot tell which table a smell belongs in, treat it as a danger sign. Water leaking from the indoor unit is a reason to stop using it too: see the guide to a split system leaking water inside.

What usually causes a burning smell from an air conditioner?

Something electrical in the unit or in its power supply is overheating. These are the usual causes. All of them are inside the unit or in its supply, which is why none of them is for an owner to look into.

Usual causes of overheating, smoke or fire
CauseWhat is going on
A power supply that is shared, extended or not the unit's ownAn air conditioner needs a circuit of its own. An extension cord, a shared outlet or a shared circuit can overheat.
A power cord or cable that is damaged or running hotA cord that is damaged, or hot to the touch, is a fault in itself.
Dirt built up in a unit left unused for a long timeDust and dirt on the parts inside can overheat when the unit runs again.
Cleaning products reaching the electrical parts or the motorSprays and detergents inside the unit can cause a malfunction, smoke or fire.
Small animals in the outdoor unitLeaves and debris around the unit shelter small animals, and one that touches the electrical parts can cause a fault, smoke or fire.

A burning smell on the first use after a long break is treated the same way: off, and call. One thing looks like smoke and is not: in heating, vapour from a defrost can look like white smoke at the outdoor unit. If there is any burning smell with it, or you are not sure, treat it as a danger sign.

What if my air conditioner keeps tripping the circuit breaker?

Treat the first trip as the warning. Do not switch the breaker back on to see whether it holds, and do not run the unit to make it trip again. Work at the switchboard is electrical work, and Energy Safe Victoria tells households not to do their own (opens in a new tab).

What helps is a description of the trip. Without touching the switchboard again, write down:

  • which breaker or switch went off, if it is labelled
  • what the air conditioner was doing at the time: starting, running or stopping
  • the mode, and how long it had been running
  • whether anything else in the house went off with it
  • the weather: heavy rain, a storm, or a very hot or very cold day
  • whether it has happened before, and when

If the trips began after a power cut or a storm, the guide to air conditioner problems after a power outage covers what else to record. If the unit has been hit or flooded, see the guide to a damaged air conditioner outdoor unit.

Circuit breaker or safety switch: which one tripped?

They do different jobs, and which one went off is worth writing down. This is how Energy Safe Victoria describes them (opens in a new tab):

What each switch does
SwitchWhat it does
Circuit breakerProtects against short circuits and current overloads, such as an overloaded power point.
Safety switchMonitors the flow of electricity through a circuit and turns the power off within 0.03 of a second when it detects a problem. It is extra protection used with breakers and fuses, and it may not protect all wiring and appliances.

So the circuit of an air conditioner may have a breaker and no safety switch. Either way the answer on this page is the same: an air conditioner that trips its breaker or its safety switch is switched off and reported, not switched back on.

What is safe to write down about a burning smell?

Only what you have already noticed. Do not go back to the unit to smell it again, and do not run it to see whether the smell returns. Write down:

  • which unit the smell came from: indoor, outdoor or not sure
  • what it smelt like, in your own words
  • whether you saw smoke, a mark on the unit or a flashing light
  • what the unit was doing, the mode, and how long it had been running
  • whether it was the first use after a long break
  • what you switched off, and when

You do not need to name a cause. A plain account of what happened is what a technician can use.

Stop-use record for a burning smell or a tripped breaker

Air conditioner stop-use record

Fill this in from what you already noticed, then copy it or print it. Leave the unit off while you do.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

Your system

Type of system

What happened

What you noticed
Which unit
What the air conditioner was doing
You saw smoke, sparks or a scorch mark

What you did

Switched off at the controller
Its power point or breaker

Conditions and history

First use after a long break

What happens next, and how urgent is it?

Stop using the unit and call straight away. It is an emergency if there is smoke or flame. Running on in this condition can cause a malfunction, a fire or an electric shock, so the unit stays off until it has been inspected. When we come out to a burning smell or a tripping breaker, we usually:

  • look for heat damage at the unit, its cord or cable and its connection to the house
  • test the electrical parts of the unit and the circuit that supplies it, before any power goes back on
  • tell you what failed, and whether the fault is in the unit or in the house wiring
  • leave the unit switched off if it is not safe to run

The Australian Refrigeration Council says servicing and repairs of a home air conditioner need a full refrigeration and air conditioning licence (opens in a new tab). Where the fault is in the wiring, Energy Safe Victoria says problems such as circuit breakers and safety switches turning off are a reason to contact a licensed electrician (opens in a new tab).

Who do I call: an electrician or an air conditioning technician?

You do not have to work that out first. Call ABL or your installer, describe what happened, and say what tripped or what you smelt. The table shows who does each kind of work.

Who does the work
The workWho does it
Anything inside the air conditioner, or on its pipesA refrigeration and air conditioning technician. In Australia, work that involves handling a scheduled refrigerant, or a part of the equipment that could release one, needs a licence, as the refrigerant handling code of practice (opens in a new tab) (2025 edition) sets out.
The house wiring, the switchboard, a power point or the breaker itselfA licensed electrician. Energy Safe Victoria says to engage a registered electrical contractor for any type of electrical work, and that you can and should ask to see a tradesperson's licence (opens in a new tab).
A fire, or any life threatening or time critical emergencyTriple Zero (000).

ABL repairs and services air conditioners for homes and businesses in Bairnsdale and East Gippsland. Our air conditioning repairs page explains how to book. Leave the unit off until it has been looked at.

Sources (10)

Want a technician to look at it?

Call ABL or send an enquiry. Have your notes ready: the brand, the model and what the unit is doing.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.