Ducted air conditioning and empty rooms: how to use your zones
How to run a ducted system's zones for rooms you are not using, which zones must stay open, why closing vents is not zoning, and a zone plan to fill in.
Last updated
Switch off the zones of rooms nobody is using and close their doors, but find out first which zones your system needs to keep open. A ducted system has to keep some air moving over its indoor coil, so a zoned one is usually set up with a zone that stays open, a zone that opens by itself, or a bypass duct. Shutting the vents in empty rooms is not the same as zoning: it pushes the same air through fewer outlets, and the system has no way of knowing those rooms are shut.
How to use this guide
Step 1: Learn the limits
Which zones must stay open, and how many can run at once.
Go to Zones that stay openStep 3: Fill in the zone plan
Your zones, the combinations you use, and what you notice.
Go to the record
Why do some zones have to stay open?
The indoor unit needs a certain amount of air passing over its coil whenever it runs. If too few zones are open, the outlets that are left can get noisy, the pressure in the ducts rises, and the unit may slow down or stop to protect itself. So a ducted system is set up with one of these:
| Arrangement | How it works | What it means for empty rooms |
|---|---|---|
| A common zone | One area, often the main living area, is always open when the system runs. | That area gets air whether anyone is in it or not. Leave its door open. |
| A spill zone | A zone set to open by itself when too few others are open. | A room used as a spill zone can get very warm or cold when it opens, so a bedroom is a poor choice for one. |
| Constant zones | One or more zones the controller opens to relieve the pressure when too few others are open. | On some controllers the constant zones can be changed, which helps when a room changes use. |
| A bypass | A duct and damper that let spare air pass from the supply side straight back to the return. | No room has to stay open for it. |
How many zones must stay open differs between systems. Some keep one to three constant zones, and on others the installer sets the smallest number of zones that may run at once. The manual or the installer's notes for your system say which, and the controller may show it in its settings. Do not run fewer zones than that minimum. Some systems are also sized to run only part of the house at once. If yours has a most-zones limit, running more zones than that stops it keeping the rooms at the setting.
Which zones do you have?
A zone is a room or a group of rooms that the controller switches on and off together. Each zone has a motor-driven damper in its duct, and one zone can feed several outlets. On some systems each zone also has its own temperature sensor and setting, and on others every zone that is on gets the same air.
The names on the controller are only as good as whoever typed them in. Check them on a mild day, keeping within the limits above. Leave on the zones your system keeps open, or as many as its minimum, then switch one other zone on and off at a time for a few minutes and walk the house to see which outlets start and stop blowing. Outlets that blow in every test belong to the zones you left on. Write down the rooms each zone really serves, and any room whose outlet blows with more than one zone. Our ducted heating and cooling page explains the kinds of zoning a system can have.
Should you close the vents in rooms you do not use?
Not as a way of zoning. The blades in an outlet are there to balance the air between the outlets of one zone when the system is set up, not to switch a room off. Closing them pushes the zone's air through fewer outlets, which can make those outlets noisy and raise the pressure in the ducts, the same trouble as closing too many zones. Keep the return air grille clear as well: blocking it starves the system of air.
Where an unused room shares a zone with a room you use, it gets air whenever that zone runs. That is a reason to have the zones changed, not to shut the outlet. Changing a zone means work on the dampers, the ducts or the controller's set-up. As at November 2026, Victoria's Plumbing Regulations 2018 (opens in a new tab) make work on the ducts and registers of a heating or cooling system mechanical services work, a class of plumbing work, and set out the requirements a licensed or registered plumber follows when doing it. So leave the ducts, outlets and dampers to the trade, and keep out of the roof space.
What does it cost to heat or cool empty rooms?
A ducted system that heats or cools the whole house when only part of it is in use spends energy on empty rooms. Zones are how you stop that: heat and cool the rooms you are using and close the doors to the rest. These are the usual places zoning changes what a system uses:
- bedrooms during the day, and living areas overnight
- a spare room, a guest room or a study that is not used every day
- rooms that are empty for the season, such as a child's room while they are away
- a common zone that stays open whenever the system runs, which is a reason for it to be the area you use most
How much you save depends on the system, the rooms and how long they are left off, so there is no fixed figure. To see the difference for your home, compare your electricity use over similar weeks, and change one thing at a time. The guide to air conditioner output and electricity usage has the method, and the guide to planning timers around household routines covers schedules.
What changes when a bedroom becomes a home office?
A room that changes use changes when it needs air. Revisit the zone plan whenever that happens:
- A bedroom becomes an office. It now needs air by day, while the other bedrooms do not. If it shares a zone with them, it gets air only when they do. Ask whether it can become its own zone. A small room such as a study may be below the airflow a zone needs on its own, and then it has to share a zone with another area. The guide to an air conditioner for a home office covers the other choices.
- A room is no longer used. Switch its zone off and close its door, as long as it is not the common zone or the only spill or constant zone.
- Someone now sleeps in a spill or constant zone. That room may be opened by the system when others close. Ask for another room to take that job.
- The common zone is no longer the room you use most. It still gets air every time the system runs, so ask whether a different area should be the common zone.
Write down what you notice before anything is changed: which rooms are too warm or too cold, when, and with which zones on. That record is what a technician needs to decide whether the zones, the balancing or the settings should change.
Ducted zone plan
When to call
If one room stays warmer or colder than the rest with its zone on, see the guide to one zone of a ducted system not cooling, which has a map to fill in. If you are planning new zones, or a system for a house with more than one level, see the guide to a zoning plan for connected rooms and levels. For where the air comes back to the unit, see the guide to ducted supply outlets and return grilles.
We install, service and repair ducted systems in Bairnsdale and East Gippsland. Our ducted heating and cooling page explains the work, and our air conditioning page covers everything else we do.
Sources (12)
Checked on 20 November 2026
- Your Home (Australian Government): heating and cooling (opens in a new tab)
- Plumbing Regulations 2018 (Vic), version 010, 1 May 2026 (opens in a new tab)
- Fujitsu General Australia: AnywAIR ducted controller, setting up zones (opens in a new tab)
- Mitsubishi Electric Australia: ducted air conditioning (opens in a new tab)
- Mitsubishi Electric Australia: zone controller installation manual (opens in a new tab)
- Polyaire: AirTouch 5 installer manual (opens in a new tab)
- Polyaire AirTouch: what is a spill zone (opens in a new tab)
- Advantage Air: MyAir user manual, version 4.1 (opens in a new tab)
- Myzone 3 zone control installation manual (opens in a new tab)
- Rinnai Australia: ducted air conditioning operation and installation manual (opens in a new tab)
- Actron Air: Advance 2 indoor unit installation guide (opens in a new tab)
- ABL Refrigeration: air conditioning services (opens in a new tab) ABL's own page.
Related pages
- Ducted heating and cooling in Bairnsdale and East Gippsland
How a ducted system is laid out, zoned and quoted.
- One zone of a ducted air conditioning system not cooling: map it before you call
When one room stays warm or cold with its zone on.
- Air conditioning connected rooms and levels: a zoning plan
Planning new zones across rooms and levels.
Rethinking your zones?
Call ABL or send an enquiry, and have your zone plan and the controller model ready.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.