A refrigeration contingency plan for a small food business
Plan for a coolroom or freezer failure before it happens: critical stock, a backup that works, who decides, who to call, power and records.
Last updated
A refrigeration contingency plan is a page you write before anything fails. It names the stock you can least afford to lose, where each lot goes if its fridge, freezer or coolroom stops, who decides what happens to it, who you ring, and how you record it all. Check the backup space before you need it and walk through the plan once with your staff. On the day, the decisions are already made.
How to use this guide
What goes in a commercial refrigeration contingency plan?
| Part | What to settle before anything fails |
|---|---|
| Critical stock | For each unit, what it holds, roughly how much, and which lots you would save first. |
| Backup cold space | Where each lot goes, at the right temperature, with room for it on a full day. |
| Decisions | Who decides to move, keep or throw out stock, and who can call a technician and approve the cost, including after hours. |
| Contacts | Your refrigeration technician, an electrician, the electricity distributor's faults line, your food regulator, your insurer and your landlord. |
| Equipment details | The brand and model of each critical unit from its nameplate, and when it was last serviced. |
| Records | Where the probe thermometer and the temperature log are kept, and where suspect stock is held. |
| Power | What happens in a planned power interruption, and whether backup power can be connected safely. |
| Testing and review | When the plan was last walked through, and what changed after the last incident. |
Which stock matters most, and where can it go?
Start with the stock that costs most to lose or is hardest to replace, unit by unit. Then, for each lot, name a place it can go and check that place now, not on the day:
- The right temperature. The food standard keeps potentially hazardous food at 5°C or below, or 60°C or above, unless the business can show another temperature is safe. So chilled stock of that kind needs a space that holds 5°C or below, and frozen stock needs a freezer that keeps it completely frozen.
- Room on a full day. Measure the space on your busiest day, not your quietest. A fridge packed past its capacity cannot keep its contents cold, because the air has to move around the food.
- Stock that is still cold. Display cabinets and refrigerated vehicles are built to hold stock at temperature, not to pull warm stock down. Move stock while it is still cold, and have a backup unit running at temperature before anything goes in.
- Someone to move it. Who carries it, in what, and how long it takes.
If one coolroom holds most of your stock and nothing else could take it, write that down plainly: it tells you what is at risk, and what a second room, a spare cabinet or regular servicing is worth to you. We hire out coolrooms, and what we have free changes from week to week, so hire is something to book ahead for a planned job, not something a plan can count on in an emergency. Our coolroom hire page explains what a hire needs.
Is your backup really a backup?
Spare space is room you have on a normal day. A backup is space that still works when the main unit has failed, for the reasons most likely to stop it. Check what your backup shares with the unit it covers:
| Shared with the main unit | Why it matters | What to check |
|---|---|---|
| The power supply | A power cut or a tripped circuit stops both. | Whether they are on separate circuits, and whether either can run on backup power. |
| The refrigeration system | Two rooms or cabinets can run off one condensing unit, so one fault stops both. | Ask your technician which units share equipment. |
| The building | Flood, fire or a closed site takes both. | Whether the backup is somewhere else entirely. |
| The busy days | A neighbour's spare fridge is full on the same event weekend as yours. | When the backup is least likely to have room. |
| Someone else's booking | Hire or borrowed space may be taken when you need it. | What the arrangement is, in writing, and who to ring. |
Who decides, and who do you call?
Two decisions get mixed up on the day. Getting the equipment running again is the technician's job. Deciding what happens to the stock belongs to the food business, under its own procedure: a repair does not make food safe again. Name one person for each, and a stand-in for when they are away.
Know your food regulator before you need it. As at November 2026, Safe Food Victoria (opens in a new tab) licenses dairy, meat and seafood businesses, and councils register most other food businesses through their environmental health teams. After a flood, Food Standards Australia New Zealand's advice on floods (opens in a new tab) is to contact your food regulator before you reopen.
When a unit fails, our coolroom and commercial fridge repairs page says what to tell us, how to reach the emergency line, and what the food standards say about the stock while you wait. Put our number in the plan beside your other contacts.
How do you keep track of stock while it moves?
Moved stock is easy to lose track of, and the record is what lets you, your regulator or your insurer see later what happened. Plan for these:
- A thermometer that can measure the food itself to within plus or minus 1°C, usually a probe, kept where staff can find it. The food standard asks for one wherever potentially hazardous food is handled, and Food Standards Australia New Zealand's guide (opens in a new tab) recommends checking the food itself rather than relying on the refrigerator's own gauge. A cabinet's display reads the air, not the food.
- A label for every moved lot: where it came from, when it moved and its temperature then.
- A place for suspect stock, held apart and clearly marked until someone decides what happens to it. A shelf set aside for it is enough.
- The corrective action, written down. A business that must keep temperature records under the food safety management tools (opens in a new tab) must act when a record shows equipment has broken down, and Food Standards Australia New Zealand's guide to those tools (opens in a new tab) says the action taken should be recorded too. The records are kept for at least 3 months, as at November 2026.
The guide to a temperature record sheet for a commercial coolroom has the sheet, and covers records when food moves between fridges and when a temporary unit comes in.
Planning around a power interruption or an installation
A planned outage is the easiest failure to plan for, because you know it is coming. As at November 2026, the Electricity Distribution Code of Practice (opens in a new tab) requires the distributor to give at least 4 business days' written notice of a planned interruption, with its date, time and expected length, unless you have agreed to it for set hours on a set date. If you chose electronic notices, a reminder comes one business day before. Distributors can take your contact details from your electricity retailer, so check the retailer has the business's phone and email, not only the owner's home.
Refrigeration work you have booked is a planned outage too: a new coolroom, a replacement unit or a major repair. For either kind:
- Ask how long the unit will be off, and plan for longer.
- Run stock down beforehand, and move deliveries until after it is back on.
- Pick the quietest trading day you can, and move critical stock to the backup while it is still cold.
- Keep coolroom and fridge doors shut while the power is off.
- When the power or the unit is back, check the temperature of the food and write it down.
Backup power: what to settle with an electrician
A generator can carry refrigeration through an outage, but connecting it is not a job for the day. Energy Safe Victoria (opens in a new tab)'s advice to households is never to connect a generator into a wall socket or switchboard unless there is an existing dedicated generator inlet, because it can feed back into the network and put line workers and neighbours on the same local network at risk. Changes to wiring are for a licensed electrician, and a portable generator runs outdoors only, because of carbon monoxide.
So settle it in advance: in a widespread emergency, electricians are likely to be in short supply. An electrician sizing backup power needs:
- the brand, model and electrical rating from the nameplate of each unit it has to run
- which units have to run at the same time, and which can wait
- how long it has to run, and the fuel that takes
Motors draw more as they start, so starting units one after another can lower the size needed. Your distributor may ask to be told about a wired-in generator: AusNet, for example, asks to be contacted first about any permanent or wired-in connection, so it can check the lines are safe for its field teams. Once it is in place, check it regularly and show staff how it is used.
Functions, events and harvest: planning for a short peak
A big function, a local event or a harvest pushes everyday storage past what it was set up for, and a unit that copes on a normal week can fall behind when it is packed and opened all day. Plan the peak from what you will actually store:
- the stock for the peak, in cartons, kegs, crates or bins, against the space you have
- deliveries split across the days, so stock arrives as it is needed
- stock arriving already cold, because the unit is there to hold it cold
- extra space booked well ahead, with dates, if you need it
- what happens if the main cold store is out of action in the middle of it
What differs is where the extra load comes from. For a function or an event, it goes in on the day and the doors open all through it. If you cater away from your own premises, check the equipment beforehand and organise backup power. For a harvest, it is field heat in produce coming in day after day: the guide to coolroom loading during a concentrated harvest covers it with a peak-day plan.
What should you check in a temporary refrigeration proposal?
Before you rely on a temporary unit, from a hire company, a supplier or a neighbour, ask:
- what temperature it holds, and whether it can freeze or only chill
- whether it fits your stock, counted in cartons or pallets
- what power it needs, and whether your supply can carry it
- whether it will be running at temperature before you load it
- who checks its temperature, how often, and with what
- how it is monitored after hours, and who gets the alarm
- how stock comes back out, and when it has to be returned
Write the answers into the plan. A proposal with no answer on temperature or power is not yet a backup.
The freezer is running again, but the stock is soft
A unit that is running again tells you about the unit, not the stock. Under the food standard, frozen means completely frozen: food that has begun to thaw has not been kept frozen. While the business decides, hold the soft stock apart and marked, measure the food itself with a probe, along or between the packs where it is packaged, and write down the times and temperatures. The guide to food temperature and fridge readings explains why a display is not enough. Our repairs page sets out what the food standards say about chilled and frozen food after a failure.
How do you test the plan without a breakdown?
Talk it through. Sit down with the staff who would be on shift, pick a likely failure, and walk the plan step by step. For example: the main coolroom stops at six on a Friday evening with a full weekend order inside. Then check the things the talk-through relies on:
- Ring each number in the plan, or check it is current.
- Look at the backup space today, and measure what it could take.
- Find the probe thermometer and the temperature log, and check the thermometer works.
- Find the nameplate details for each critical unit.
- If you have backup power, have it checked and make sure staff know how it is used.
- Write down what did not work, change the plan, and date it.
Walk through it again when staff, suppliers, equipment or the layout change.
What to review after a refrigeration incident
Keep a running log on the day: the time of each reading, decision and call. Once things are back to normal, sit down with it and go through:
- what happened, in order, from the log
- what the technician found, from their service report, rather than a guess
- what stock was moved, kept or thrown out, and what it cost
- which parts of the plan worked, and which did not
- what changes: a contact, the backup, a service, a second unit
A fault that comes and goes is worth logging before the next visit: the guide to intermittent refrigeration faults has a log for it. Regular servicing is part of the plan too, and our commercial refrigeration maintenance page covers what a visit includes.
Refrigeration contingency plan
Sources (21)
Checked on 20 November 2026
- Food Standards Australia New Zealand: storing food safely (opens in a new tab)
- Food Standards Australia New Zealand: thermometers and using them (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2A (opens in a new tab)
- Food Standards Australia New Zealand: the evidence tool for category one businesses (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, appendix 8, record templates (opens in a new tab)
- Food Standards Australia New Zealand: floods and food safety (opens in a new tab)
- Safe Food Victoria (opens in a new tab)
- Safe Food Victoria: food safety during power outages (opens in a new tab)
- Safe Food Victoria: FoodSmart food safety program template, June 2025 (opens in a new tab)
- Energy Safe Victoria: using a generator safely (opens in a new tab)
- Essential Services Commission: Electricity Distribution Code of Practice, version 3 (opens in a new tab)
- AusNet: preparing your business for a power outage (opens in a new tab)
- AusNet: planned outages (opens in a new tab)
- Dairy Australia: preparing for power outages (opens in a new tab)
- business.gov.au: develop an emergency management plan (opens in a new tab)
- business.gov.au: prepare your business for an emergency (opens in a new tab)
- Business Queensland: business continuity plan (opens in a new tab)
- Business Queensland: preparing an incident response plan (opens in a new tab)
- Australian Food and Grocery Council: Australian cold chain guidelines 2017 (opens in a new tab)
- ABL Refrigeration: commercial refrigeration (opens in a new tab) ABL's own page.
Related pages
- Coolroom and commercial fridge repairs in East Gippsland
What to tell us when a unit fails, and what to do with stock while you wait.
- Commercial coolroom temperature record template and log
The sheet for readings, including when food moves.