Coolroom and commercial fridge repairs in East Gippsland
ABL repairs coolrooms, freezer rooms and commercial fridges in East Gippsland. What to do with the stock, the usual causes of each fault and what to tell us.
Call ABL and say what has failed and what temperature it is showing. Have the brand and model ready, and tell us when the fault started. For an urgent fault, use the emergency line.
How to get a repair
Step 1: Protect the stock
Move food under your food safety procedure and write down the temperatures you measure.
Go to Food safetyStep 2: Write down the details
The equipment, the temperature it shows, what it is doing and when it started.
Go to the record
Look after the food first
A failed coolroom or cabinet is a food safety matter as well as an equipment fault. Your food safety procedure says where stock goes and when it is thrown out. These are the points it rests on.
| Question | What the food standards say |
|---|---|
| How cold does chilled food have to be? | Potentially hazardous food is kept at 5°C or colder, unless the business can show that another temperature keeps it safe. See keeping food at the right temperature (opens in a new tab), from Food Standards Australia New Zealand (FSANZ), updated 30 September 2025. |
| What about frozen food? | Frozen food has to stay frozen. The standard gives no freezer temperature as a number. See Safe Food Australia, chapter 3.2.2 (opens in a new tab). |
| How do I know how warm the food is? | Measure the food itself with a thermometer. FSANZ says the best way is a probe thermometer in the thickest part of the food. The standard asks for a thermometer accurate to plus or minus 1°C. |
| What about food that has warmed up? | Your procedure decides. The 2-hour/4-hour rule below is the guide FSANZ publishes. |
| Does a repair make the food safe again? | No. A repair or a temperature setting does not decide whether food is safe. That decision belongs to the food business. |
What does the 2-hour/4-hour rule say?
FSANZ publishes the 2-hour/4-hour rule (opens in a new tab) for food that is taken out of the fridge. It counts the total time the food has spent between 5°C and 60°C.
| Total time between 5°C and 60°C | What you can do with the food |
|---|---|
| Less than 2 hours | Use it, sell it, or put it back in the fridge to use later. |
| Between 2 and 4 hours | Use it or sell it. It cannot go back in the fridge to use later. |
| More than 4 hours | It cannot be sold and must be thrown away. |
- The time adds up. Count every period the food has been between 5°C and 60°C, including preparation, storage, transport and display.
- FSANZ calls the rule a guide. It is not the law, and it does not replace your food safety procedure.
- FSANZ wrote it for food taken out of a fridge. How your business applies it when the fridge itself fails is for your procedure to say.
- FSANZ ends with one line: if in doubt, throw it out.
What to do with the stock while you wait
The published advice on a fridge or freezer that has stopped is written for power failures at home. We found nothing equivalent for a coolroom or a commercial cabinet, so treat these steps as a starting point and follow your own procedure.
| Step | What to do |
|---|---|
| Keep the doors shut | Open fridge and freezer doors only when you have to, so the food and the air stay colder for longer (Victorian Department of Health (opens in a new tab), February 2021). |
| Move what you can | The department says to move food from the fridge to the freezer. Your procedure should name the working refrigeration your stock goes to. |
| Use ice | If the failure lasts more than an hour, the department says to put bagged ice under food packages and trays. |
| Measure the food and note the time | Put a probe thermometer in the thickest part of the food, and write down each reading with its time. |
| Know how long a closed unit holds | For a home fridge, FSANZ says around four hours (opens in a new tab) before food can begin to spoil. For a home freezer, it says around 24 hours before it defrosts. No source gives a figure for a coolroom or a commercial cabinet, so go by your readings. |
| Frozen food | The department says frozen food that is still solid when the power comes back is safe to refreeze. FSANZ says not to refreeze frozen food that has thawed. |
Write down the time you found the fault and each temperature you measure. A licensed dairy business follows its approved food safety program, and Safe Food Victoria (opens in a new tab) monitors that it does.
To plan for the next failure before it happens, see the guide to a commercial refrigeration contingency plan. For what a cabinet display does and does not tell you, see the guide to food temperature and fridge readings.
What ABL repairs
- walk-in coolrooms
- freezer rooms
- display fridges and glass-door fridges
- commercial kitchen refrigeration
We work for cafes, restaurants, bars, shops, butchers, farms and cold stores. Tell us the brand and model when you call.
For an ice machine, see the ice machines page. If the room is past repair or too small, see the coolroom and freezer room installation page. Our other work is on the commercial refrigeration page.
Warning signs, usual causes and what you can check safely
Five checks need no tools and open nothing: the door, the door seal, the power, the alarm and the path of the air. Look, write down what you see, and call. The last column gives the usual causes, so you know what we will be looking for.
| What you notice | What to look at and write down | What we usually find |
|---|---|---|
| It is too warm, or the temperature swings | Is the door fully closed, and is it being opened a lot? Is stock blocking the air slots or packed tight? Is anything stacked against the grille of the refrigeration unit, or is the air around it hot? Note the display reading, the time and the food temperature. See the guide to coolroom temperature recovery. | A blocked condenser, low refrigerant, a coil that has iced over, a failed fan motor or a faulty temperature sensor. |
| Heavy frost or ice | Look along the door seal for gaps, tears or ice, and see whether the door closes fully. Note where the frost is and how long it has been building. See the guide to coldroom condensation and frost. | A defrost heater, timer or thermostat that has failed or is wrongly set, or air leaking in around a door. |
| It runs all the time | Note when you first noticed it, and whether the temperature is still holding. Look at whether anything is stacked against the grille of the refrigeration unit. | A blocked condenser or poor ventilation around the unit, and otherwise much the same list as for equipment that runs warm. |
| An alarm sounds, or a code shows | Write down the code or what the alarm says, and the model. Codes differ from maker to maker. See the guide to commercial fridge alarms. | A failed temperature sensor is a common one, and it needs a service call. Not every code is a fault: on some cabinets a code only shows that a defrost is in progress. The manual for your model lists its codes. |
| Nothing is lit | Is the plug in and the power point on? Power supply is the first thing to rule out. Note whether the display, the light and the fan have all stopped, and whether anything else nearby has lost power. If a breaker or safety switch has tripped, leave it and read the next section. | A loss of power supply to the equipment. On a walk-in whose fans have stopped, a main switch that is off or a blown fuse. |
| The fault comes and goes | Note the time of each episode and what was happening: the hottest part of the day, a busy service, a delivery. See the guide to recording intermittent faults. | Overload protection that trips and resets itself, a dirty condenser coil, or loose wiring. |
| A new noise | Note where it comes from, what it sounds like and when it happens. | A worn compressor, pipework that needs better support, or a fan motor that no longer turns smoothly. |
| The door will not seal, or ice forms around a freezer door | Is stock or a shelf stopping the door? Is the seal torn or dirty? Door seals need regular cleaning, and replacing once they are damaged. | A damaged seal. On a walk-in, condensation or ice around a door usually means an air leak or a failed door heater. |
The table gives usual causes, not a diagnosis. Several of them look the same from outside, and which one you have is for the technician to find on site.
If it trips a circuit breaker or safety switch
Leave it off. Do not switch it back on to see whether it holds. Then write down:
- which breaker or safety switch tripped, as its label reads
- what else lost power at the same moment
- the time, and what was happening: a delivery, cleaning, a storm
- whether it has tripped before, and when
Tell us all of it when you call. In Victoria, fixed electrical installation work requires a licensed electrician, as Energy Safe Victoria (opens in a new tab) sets out, so a fault in the building's wiring goes to your electrician. A fault inside the refrigeration equipment goes to a refrigeration technician.
We treat a trip the same way. We find the cause of a shutdown and correct it before any safety switch is reset. Energy Safe Victoria's advice for homes (opens in a new tab) is to contact a licensed electrician where fuses blow or circuit breakers and safety switches turn off.
Water under a cabinet that keeps coming back
Record what you see and leave the cause to the technician. Do not take off panels, trays or drain parts to look for where the water comes from.
- where the water appears: at the front, at the back or under the door
- how much there is, and how often it comes back after you mop it up
- whether it is clear or dirty
- whether there is ice or frost inside the cabinet
- a photo of the water and of the cabinet from the front
There are a few usual causes. A cabinet that does not sit level can overflow its condensate tray. On a walk-in, a blocked drain line or a failed drain heater lets ice build in the drain pan until water spills. Which one it is, the technician finds.
Keep the water away from leads and power points. If it has reached either, follow the warning at the top of this page.
What to tell the technician
Getting the site ready for the technician
- Clear a path to the equipment and to its refrigeration unit, wherever that sits.
- Have someone on site who has seen the fault.
- Have keys and gate codes ready.
- Put the manual, your temperature records and any earlier service reports where the technician can read them.
Leave the equipment itself alone. Do not take off panels, do not defrost it by hand and do not clean inside the refrigeration unit before the visit. The technician needs to see the fault as it is.
What the technician does, and why it is a technician's job
On a breakdown call we usually work in this order.
- We find the cause before anything is reset or replaced.
- Where refrigerant is low, we test for leaks and repair any we find before more goes in.
- We replace the part that has failed, or clean what is blocked.
- We watch the system closely once it is running again.
- We record the work, and any refrigerant that went in, in the logbook.
This page gives no repair steps, and that is deliberate. Under the refrigerant handling code of practice (opens in a new tab) (part 2, 2025 edition), anyone whose work involves handling a scheduled refrigerant, or a part of the equipment that could release one, must be licensed. The code also says a system known to be leaking must not be topped up with refrigerant until all leaks are fixed.
The code covers scheduled refrigerants only. Hydrocarbons, ammonia and carbon dioxide are outside it. Whatever is in your equipment, this page still gives no repair steps.
You can check any technician's refrigerant licence at Look for the tick (opens in a new tab).
Repair or replace?
The technician can tell you what the repair involves. Whether to go ahead is your decision. These are the things that weigh on it.
| What to weigh | What to know |
|---|---|
| Age | The federal government's refrigeration guide for businesses (opens in a new tab) says a system more than 10 years old should be considered for replacement, and that an efficient new system could save up to 30% in energy use. |
| What has failed | Some repairs are a part. A worn compressor is replaced whole, so ask for that price beside the price of new equipment. |
| The refrigerant inside | Existing equipment can keep running. The phase-down of HFC refrigerants covers imports of bulk gas, and the federal environment department's page on it (opens in a new tab) says existing equipment is not affected. For the older refrigerant R22, the Australian Refrigeration Council's fact sheet (opens in a new tab) says existing units can still be serviced with it, that imports end on 1 January 2030, and that spare parts might become harder to source. |
| Running cost | New equipment is generally more energy efficient and can be cheaper to run. Ask what a new unit would use against the old one. |
| The stock it protects | What one more failure would cost you in stock and lost trade. Only you know that figure. |
For the sums, see the guide to repair or replace commercial refrigeration.
After the repair
The refrigerant handling code of practice (opens in a new tab) (part 2, 2025 edition) recommends periodic preventative maintenance, and a routine maintenance agreement where a business has no trained staff of its own. If the same fault keeps coming back, or the equipment has gone a long time without a service, see the commercial refrigeration maintenance page.
Towns ABL covers
ABL is based in Bairnsdale and works across Gippsland, so tell us your town when you call. A town with a link has its own page.
- Bairnsdale
- Benambra
- Bruthen
- Buchan
- Cann River
- Churchill
- Eagle Point
- Ensay
- Heyfield
- Lake Tyers
- Lakes Entrance
- Lindenow
- Maffra
- Mallacoota
- Marlo
- Metung
- Moe
- Morwell
- Nowa Nowa
- Omeo
- Orbost
- Paynesville
- Sale
- Stratford
- Swan Reach
- Swifts Creek
- Traralgon
If your town is not here, call and ask. See also service areas.
Sources (22)
Checked on 17 November 2026
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page.
- ABL Refrigeration: service areas (opens in a new tab) ABL's own page.
- Food Standards Australia New Zealand: keeping food at the right temperature, updated 30 September 2025 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter 3.2.2 (opens in a new tab)
- Food Standards Australia New Zealand: 2-hour/4-hour rule, updated 30 September 2025 (opens in a new tab)
- Safe Food Victoria: compliance monitoring for dairy, updated 1 July 2026 (opens in a new tab)
- Australia and New Zealand refrigerant handling code of practice, part 2, 2025 edition (opens in a new tab)
- Energy Safe Victoria: electrical licence types (opens in a new tab)
- Australian Refrigeration Council: Look for the tick (opens in a new tab)
- Australian Government: Triple Zero (000) (opens in a new tab)
- Food Standards Australia New Zealand: food safety in an emergency, updated 2 October 2025 (opens in a new tab)
- Victorian Department of Health: power outages, food safety after a power failure, February 2021 (opens in a new tab)
- Heatcraft: installation and operations manual for unit coolers, evaporator troubleshooting chart (opens in a new tab)
- Heatcraft: installation and operations manual for condensing units, system troubleshooting chart (opens in a new tab)
- Bally Refrigerated Boxes: walk-in coolers and freezers service manual, 2013 (copy held by a reseller) (opens in a new tab)
- SKOPE: user manual for the SC430N upright glass door fridge, February 2022 (opens in a new tab)
- Williams Refrigeration Australia: operating manual for upright and counter refrigeration, April 2020 (copy held by a reseller) (opens in a new tab)
- Energy Safe Victoria: power outages and energy safety, reviewed 9 April 2024 (opens in a new tab)
- SafeWork SA: cold storage facilities (opens in a new tab)
- Australian Government, energy.gov.au: refrigeration guide for businesses (opens in a new tab)
- Department of Climate Change, Energy, the Environment and Water: HFC phase-down, updated 4 June 2026 (opens in a new tab)
- Australian Refrigeration Council: fact sheet 26, R22 gas and equipment (opens in a new tab)
Related pages
- Commercial refrigeration maintenance in East Gippsland
Planned servicing, for equipment that keeps failing or has not been serviced for a while.
- A commercial refrigeration contingency plan
Decide where stock goes before the next failure.
- Recording intermittent commercial refrigeration faults
What to note when the fault is gone by the time anyone looks.
Coolroom or commercial fridge failed?
Call ABL or send an enquiry, and have the equipment, the temperature it shows and what it is doing ready.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.