Intermittent commercial refrigeration faults: what to record before the technician arrives

How to log alarms, shutdowns, noises and trips that come and go, which photos to take safely, and the repair history to have ready for the technician.

Last updated

An intermittent fault is often gone by the time a technician arrives: an alarm that clears itself, a cabinet that stops and starts again, a noise or a breaker that trips now and then. So the evidence has to come from the people on site. A record of each event, with the time, what the display said, what you saw and heard and what was going on around it, shows us where to look. Add photos taken without opening anything and the reports from earlier repairs, and the visit starts from facts.

How to use this guide

  1. Step 1: Know what to note

    The time, the message, what you saw and heard, and what was going on.

    Go to What to record
  2. Step 2: Log each event

    Fill in an entry each time, and keep the earlier repair reports with it.

    Go to the record
  3. Step 3: Call

    Read the log out, or paste it into your enquiry.

    Call (03) 5153 2650

Commercial fridge troubleshooting: why does a fault come and go?

Before you start a log, do the five checks on the commercial refrigeration repairs page: the door, the door seal, the power, the alarm and the path of the air. They need no tools and open nothing. If the fault still comes and goes, these are the usual reasons it has stopped by the time anyone looks.

Faults that come and go, and what can be behind them
What comes and goesWhat can be behind itWhat your log can show
An alarm or code that clears itselfOn many controllers an alarm clears itself once its cause passes: the temperature comes back into range, the door is shut or the supply voltage recovers. A controller can also be set to wait before a temperature alarm sounds, so by then the temperature has been out of range for a while.The exact code, the time it showed, and what was happening just before.
It stops, then starts again by itselfProtection that stops the compressor and lets it restart: an overload that trips when the compressor works too hard or runs too hot and then resets itself, or a cut-out when the supply voltage goes too high or too low. A dirty or blocked condenser, a failed condenser fan or a very hot day can push it there. Loose wiring is another cause.The time, whether lights dimmed or other equipment stopped too, the weather, and anything stacked against the grilles.
It runs warm at some times onlyThe load: doors opening through a busy service, a delivery or warm food going in. A defrost also lifts the reading for a short time, and many controllers show a symbol or message while it runs.The time, the door use and deliveries around it, and whether a defrost symbol showed.
A noise that comes and goesA steady hum from a running compressor is normal. A new knock, grinding or loud vibration can be a fan motor that no longer turns smoothly, pipework that needs better support, or a worn compressor.When it happens: as it starts, while it runs, as it stops or during a defrost.
Trouble only in cold weatherAn outdoor condensing unit can struggle to start or to run steadily when it is cold outside, unless it has controls for low temperatures. Some cabinets also have a lowest room temperature they are made to run in.The time and the outside temperature, or the temperature where the cabinet stands.
A breaker or safety switch that tripsA fault in the equipment or in the building's wiring. A wiring fault goes to an electrician, and a fault inside the equipment to a refrigeration technician.Leave it off and follow the warning at the top of this page. Note what lost power and the time, and which breaker or switch tripped if you already know.

These are usual causes, not a diagnosis. Several look the same from outside, and which one you have is for the technician to find on site. Ask for the cause to be found before any part is replaced.

What to write down each time it happens

Write each entry when it happens, not at the end of the day. A few words with the exact time tell us more than a long account from memory. Record events as they happen in normal trading, and do not try to make the fault happen.

Symptoms and display messages

  • The date and time, to the minute if you can, and how you noticed: an alarm, a warm reading, a noise or a staff member.
  • The exact message or code, letter for letter, and whether it flashed or took turns with the temperature. Codes differ from maker to maker, so write it as shown and leave its meaning to the guide to commercial fridge alarms.
  • Which symbols were lit. Many controllers have one for the compressor, the fans, a defrost and an alarm.
  • The temperature on the display, and a probe reading of the food. The display shows what its sensor reads, not the temperature of the food. See the guide to food temperature and fridge readings.
  • What you could hear: running, silent, or a noise that is new.
  • How it ended, and when: it cleared by itself, someone pressed a button, someone switched it off, or it was still going.

What was going on around it

Note what was happening just before and during the event, with times:

  • Loading: a delivery, a big restock or warm food going in.
  • Doors: a busy service, a door propped or left open, or a door that did not close by itself.
  • Cleaning: whether it was switched off for cleaning and when it went back on, and whether the floor or wall near it was hosed.
  • Power: a storm, a blackout, lights dimming, or other equipment stopping at the same moment.
  • Heat and cold: a hot afternoon, sun on the unit, an oven or fryer running nearby, or a cold morning.
  • A defrost: whether its symbol or message was showing.

If the problem is a room or cabinet that is slow to come back after doors open or stock goes in, use the timed load and recovery log in the guide to coolroom temperature recovery. This page is for events that come and go.

Which photos can you take safely?

Photograph what anyone on site can see in normal use, and note the time of each photo in the log:

  • the display while the message is showing
  • the label with the brand, model and serial number, which your manual shows you where to find
  • the equipment from the front and the space around it, including anything stacked against its grilles
  • frost, ice or water you can see with the door open in normal use, and any water on the floor
  • the outdoor unit, from where you can stand safely on the ground
  • for a noise, a short video with sound, taken from where you normally stand

Keep the service history together

Earlier visits are part of the evidence. Put these in one folder, in date order, where the technician can read them:

  • Service and repair reports: the date, what was found and what was replaced. Our own service reports record the temperatures we found, the work done and the parts replaced.
  • Invoices for parts and labour.
  • The logbook. As the refrigerant handling code of practice (opens in a new tab) sets out, a system holding more than 3 kg of refrigerant has to come with a logbook, with room to record maintenance, repairs and every part changed.
  • The manual, and any settings sheet you were given after work on the controls.
  • Monitoring reports and alarms, if a temperature monitoring system is fitted.

This log is about the fault. It does not replace any temperature records your food safety program asks for. For those, see the guide to commercial refrigeration temperature records.

The same fault keeps coming back after repairs

When a fault returns after one or more repairs, its history is the evidence for what to do next. Put it together in one place:

  • each time the fault happened, from your log
  • each visit: the date, who came, what they found and what they replaced
  • whether the fault changed after each repair, and how long it stayed away
  • the stock and trading time each failure cost you

We review the service records for repeated faults and for changes in how the equipment runs, so a clear history helps. A fault can keep coming back until its underlying cause is found and fixed.

With that history in hand, the choice between another repair and new equipment is easier to make. See the guide to repair or replace commercial refrigeration.

It behaves differently since it was moved

A cabinet that ran well in one spot can struggle in another. Before you ask for a diagnosis, note what changed with the move. The manual for your model sets the figures.

What a move can change
What changedWhat to note
How it travelledWhether it stayed upright or was tipped or laid down, and how long it stood before it was switched on. Cabinets are meant to travel upright, and to stand upright for a while before they are switched on: from a few hours to a day, depending on the maker and on whether the cabinet was tipped.
The powerWhether it is on a different power point or circuit, and whether it now runs through a power board, a double adaptor or an extension lead. Its supply has to match its rating label, and some cabinets are meant to have their own circuit with no adaptor or extension lead.
The space around itWhether anything now blocks its grilles, whether it now sits in a recess or an enclosed space, and whether it has the clearance its manual asks for at the sides, back and top.
Heat and coldSun, an oven, a fryer or a warm draught near it, or a cold spot. The climate class on its label shows the room conditions it is rated for: see the guide to commercial fridge climate classes.
LevelWhether the doors still close and seal by themselves, and whether water collects under it. A cabinet that is not level can stop its doors sealing and let its condensate tray overflow.
CleaningWhether the new spot is hosed down. Some cabinets are not made for an area where a hose or pressure washer is used.

If the move needs a new circuit or power point, that is fixed electrical work. In Victoria all fixed electrical installation work requires a licensed electrician, as Energy Safe Victoria (opens in a new tab) sets out. For a walk-in coolroom that has been moved, see the guide to relocating a modular coolroom.

A new noise or vibration after a service

A noise or vibration that starts after a service is worth reporting straight away to the business that did the work. It matters for more than the noise: vibration fatigues pipework and is behind many refrigerant leaks. Note:

  • the date of the service, and when you first noticed the noise
  • where it seems to come from: the cabinet, the outdoor unit, the pipework, or a wall or bench it touches

Do not tighten, pad, wedge or bend anything to quieten it, and do not take off a panel to find it. Checking mountings, fans, pipe supports and anything rubbing is part of the technician's inspection, and the report from that service should show what was worked on.

The cycles changed after a control was replaced

The controller holds the settings that shape a normal cycle: the temperature it aims for and how far it drifts before it acts, how often and how long it defrosts, the delays on the fans and the compressor, and the alarm limits and delays. A replacement controller starts from its own factory settings, and those are only a starting point: each one has to be checked and set for the equipment it now runs.

So after control work, ask for the agreed settings in writing, and compare how the equipment runs now with how it ran before:

  • the set temperature and the alarm limits you agreed, against what the display shows now
  • how often a defrost shows and how long it lasts, against before
  • whether it now runs much longer, or stops and starts more often
  • any new alarm or code, and when it shows
  • logger or monitoring readings from before and after the work, if you have them

Do not change the settings yourself or go into the controller's menus. If it runs differently from what was agreed, send the comparison to the business that did the work. When a cold room will not hold a steady temperature after its controls are set up, the cause can be a setting rather than a failed part.

What the technician does with your log

We read your log and the service history first. They tell us when the fault shows, what goes with it and what has already been tried. On site we look at the controller's settings and any alarm history it keeps, the airflow at the condenser and the evaporator, and the electrical protection, and we find the cause before anything is replaced. The log points us where to look. It does not replace a diagnosis on site.

Some faults will not show themselves on the day of the visit. A temperature monitoring system records the readings between visits and can alert you by SMS or email when the temperature drifts outside its range.

Intermittent fault log

Intermittent refrigeration fault log

Fill in an entry each time it happens, at the time. If you missed a reading, leave the box empty. Then read the log out when you call, or paste it into an enquiry.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The equipment

Type of equipment
What changed before it started
Earlier repair reports kept

Event 1

Event 1: what happened
Event 1: photo or video taken

Event 2

Event 2: what happened
Event 2: photo or video taken

Event 3

Event 3: what happened
Event 3: photo or video taken

The pattern and the history

A burning smell, a tripped breaker or water near the electricsIf yes, turn it off and leave it off.

How urgent is it?

What the signs mean for timing
What you seeWhat to do
A burning smell, a breaker or safety switch that trips, or water near the electricsTurn it off, leave it off and call. The warning at the top of this page applies.
Food above 5°C on the probe, or frozen food softeningYour food safety procedure decides what happens to that food, and the repairs page sets out the food safety points it rests on. Under Standard 3.2.2, as Safe Food Australia (opens in a new tab) explains it, potentially hazardous food is kept at 5°C or below or at 60°C or above, unless the business can show that another temperature is safe, and frozen food stays frozen. Then call.
An alarm or shutdown that keeps coming back, even if it clearsBook a visit and send the log. Equipment that is not working properly should be seen by a technician as soon as the problem shows, so that any refrigerant leak is kept small.
A new noise or vibration, especially after a serviceReport it now to whoever did the service, rather than at the next one.
It runs differently since a move or work on the controlsBook a visit and send what changed, with the before and after readings.

The commercial refrigeration repairs page explains how to book. Have the log and the service history in front of you when you call.

Sources (15)

A fault that keeps coming back?

Call ABL or send an enquiry with your fault log, the brand and model, and the reports from earlier repairs.