Commercial refrigeration maintenance in East Gippsland
Planned servicing for coolrooms, freezer rooms and commercial fridges in East Gippsland: what a visit covers, how often, and what staff do in between.
Send an enquiry with a list of your equipment, or call ABL. We agree what is checked and how often for your equipment, with you. If something has already failed, go to the coolroom and commercial fridge repairs page.
How to set up maintenance
Step 1: List your equipment
Each coolroom, freezer room and cabinet, with its brand, model and age.
Go to the recordStep 2: Send it or call
Paste the list into an enquiry, or read it out on the phone.
Call (03) 5153 2650Step 3: Agree the scope
What is checked, how often, and when a unit can be off.
Go to Scope and interval
Maintenance, repairs and cleaning are three jobs
| Job | What it is | Who does it | Where to go |
|---|---|---|---|
| Planned maintenance | Inspection and servicing on an agreed schedule, while the equipment is working. | A refrigeration technician, licensed where the equipment holds a scheduled refrigerant. | This page. |
| Breakdown repair | Finding and fixing a fault after something has gone wrong. | A refrigeration technician, licensed where the equipment holds a scheduled refrigerant. | The coolroom and commercial fridge repairs page. |
| Operator cleaning | The routine care your own staff do, as the manual for each model sets out. | You and your staff. | The guide to cleaning commercial refrigeration. |
Regular checks and routine care keep downtime down. The care your own staff do and the faults that need a technician are two separate lists, and the manual for your model says which is which.
The trade's own code recommends it too. The refrigerant handling code of practice (opens in a new tab) (part 2, 2025 edition) recommends periodic preventative maintenance to minimise refrigerant leakage. Where a business has no trained staff of its own, it recommends a routine maintenance agreement with a competent technician. The code covers systems that use scheduled refrigerants. Hydrocarbons, ammonia and carbon dioxide are outside it.
What does a maintenance visit include?
This is what a planned visit usually covers on a coolroom or freezer room. What we check on your equipment is agreed for your equipment, and the manual for it governs.
| Part of the system | What we do |
|---|---|
| Earlier records | We read the logbook and past reports first, for where leaks were found before. |
| Condenser coil and fans | We clean the coil and the fan blades, and check that each fan turns freely and quietly. |
| Evaporator coil and fans | We clean the coil and blades inside the room, and check the fans and that nothing blocks the air. |
| Defrost | We check the defrost controls and heaters, and look for ice building up where it should not. |
| Drain | We check that the drain pan and drain line are clear of debris and ice and drain freely, and that any heater on the drain line works. |
| Refrigerant circuit | We look for oil stains on pipes and coils, check suspect points with a leak detector, and check the sight glass and the operating pressures. |
| Compressor | We check the oil level where there is a sight glass, and listen for unusual noise or vibration. |
| Electrical parts and controls | We check that connections are secure, the condition of wiring and contactors, and the operation and calibration of timers, pressure controls and safety controls. |
| The record | We write up the visit, and enter any refrigerant that went in or came out in the logbook. |
That list is the refrigeration plant. Ask for the room itself to be looked at too: door seals, door closers, strip curtains and the joints between panels. Even small gaps between panels, or around pipes that enter a wall, let warm, moist air into a cold room.
Is planned maintenance worth it?
- Running cost. Refrigeration can be 25% to 85% of the total energy a company uses, on the federal government's figures (opens in a new tab). Regular cleaning and maintenance keeps it efficient and keeps temperatures steady.
- A measured figure. In bench tests for the federal environment department (opens in a new tab), published in October 2022, a two-door display cabinet with its condenser 40 per cent blocked used 15.7 per cent more energy.
- Fewer failures. The department says the tests show that preventative maintenance minimises equipment failure and reduces refrigerant leaks.
- Food safety housekeeping. Food Standards Australia New Zealand (FSANZ) tells food businesses to regularly maintain and service their refrigerators (opens in a new tab).
How often does commercial refrigeration need servicing?
There is no single interval. The manual for the equipment sets it, and a hard-working or dirty site shortens it. These are the usual intervals to start from.
| Equipment | Usual interval |
|---|---|
| Coolroom or freezer room: the condensing unit | Inspected every 3 months. Cleaned and fully checked every 6 months. |
| Coolroom or freezer room: the evaporator in the room | Every 6 months, or sooner where conditions on site clog or foul the coil. |
| Display fridges, glass-door fridges and upright cabinets | A light clean of the condenser coil about once a month, and a thorough clean by a technician about every 6 months. Models vary, so check the manual for yours. |
| Leak inspection, where the manual gives no schedule | Under the refrigerant handling code of practice, for a system that is not self-contained or hermetic: every 12 months where it holds more than 3 kg and up to 30 kg of a scheduled refrigerant, and every 6 months above 30 kg and up to 300 kg. A self-contained unit is inspected after a repair or when a leak is suspected. |
| Any system, by your own staff | A look once a week at how it is running and at the condition of the condensing unit, as the code of practice recommends. |
The leak inspection row is about leaks only. It is not a service interval for the whole system. For an ice machine, see the ice machines page.
What sets the scope and the interval
Under the code of practice, preventive maintenance follows the instruction manual of the system. Beyond the manual, four things shape what is checked and how often for your equipment, so we ask about them first.
| What we ask about | What to tell us |
|---|---|
| The equipment | What each item is, its brand and model, and roughly how old it is. The label on the equipment has the model and the refrigerant. |
| How hard it works | The hours and days you trade, how often doors open, and how full the room or cabinet runs. A busy season counts. |
| Where it sits | In a kitchen, a shop, a shed or outdoors, and what is around the refrigeration unit. |
| The maker's requirements | Any manual, service schedule or logbook that came with the equipment. |
Where it sits can shorten the interval. A site that clogs or fouls the coil needs inspecting sooner: a kitchen that puts grease and lint in the air, for example, or a dusty shed.
To work out a schedule of your own, see the guide to a commercial refrigeration maintenance checklist.
What do your staff do between visits?
A technician sees the equipment a few times a year. Your staff see it every day. These are the jobs that fall to the operator. Where the manual for your model says something different, follow the manual.
| Job | What to do |
|---|---|
| Check the food, not only the display | Measure the food with a probe thermometer, and do not rely only on the gauge fitted to the equipment. The food standards ask for a thermometer accurate to within 1°C (FSANZ, thermometers (opens in a new tab)). |
| Keep the temperature record | FSANZ says a category one food business should make a record each day it does a prescribed activity, and must keep it for at least 3 months (FSANZ, evidence tool (opens in a new tab)). |
| Leave room for air | Do not overstock, so chilled air can circulate, and keep the air grilles clear of stock. |
| Mind the doors | Do not open doors more often than you need to, or leave them open for long. |
| Look at the condensing unit each week | Look at how the system is running, and at the condition of the condenser coil, once a week, as the code of practice recommends. Look only. If the coil is dirty or something has changed, tell your technician. |
| Keep dust off the condenser, if your manual makes that your job | Some makers ask the owner to brush dust off the condenser coil about once a month. Others leave it to a technician. Check the manual for your model before you touch it. |
Leave the rest to the technician. Do not take off panels, do not hose the equipment down and do not chip ice off a coil. If you notice ice building up, a new noise, water on the floor or a door that no longer seals, see the warning signs on the coolroom and commercial fridge repairs page.
What drives the cost of maintenance?
- How many items, and what kind. List every coolroom, freezer room and cabinet.
- How often. The published intervals above, adjusted for your site.
- Access. Plant on a roof or in a tight plant room, and whether a unit can be switched off during trading hours.
- Where your sites are. Travel from Bairnsdale is part of the cost, so list every site.
- Condition. Equipment that has gone a long time without a service can need more than a routine first visit.
Put all five in the enquiry below and we can quote for your equipment.
What to send us
After each visit: the record and what happens next
Ask what the visit record will cover when we agree the scope. For systems that use scheduled refrigerants, the code of practice sets a floor.
- A system holding more than 3 kg of refrigerant is supplied with a logbook. It records maintenance and repairs, refrigerant added or removed, parts changed and the results of routine tests.
- All refrigerant added to a system is recorded in that logbook.
- The results of a leak inspection should be recorded.
A visit can find work that needs doing. You decide what goes ahead, with one exception the code sets: a system known to be leaking must not be topped up with refrigerant until all leaks are fixed. So a leak is repaired before the system is recharged.
For the records a food business keeps itself, see the guide to commercial refrigeration temperature records.
What ABL maintains
- walk-in coolrooms and freezer rooms
- commercial fridges and display cabinets
- farm and dairy cold storage
For a new or bigger room, see the coolroom and freezer room installation page. For alarms and logging, see the temperature monitoring page. Our other work is on the commercial refrigeration page.
Towns ABL covers
ABL is based in Bairnsdale and services refrigeration across Gippsland, so tell us where each site is. A town with a link has its own page.
- Bairnsdale
- Benambra
- Bruthen
- Buchan
- Cann River
- Churchill
- Eagle Point
- Ensay
- Heyfield
- Lake Tyers
- Lakes Entrance
- Lindenow
- Maffra
- Mallacoota
- Marlo
- Metung
- Moe
- Morwell
- Nowa Nowa
- Omeo
- Orbost
- Paynesville
- Sale
- Stratford
- Swan Reach
- Swifts Creek
- Traralgon
If your town is not here, call and ask. See also service areas.
Sources (18)
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page. Checked on 17 November 2026.
- ABL Refrigeration: service areas (opens in a new tab) ABL's own page. Checked on 17 November 2026.
- Australian Refrigeration Council: refrigerant handling codes of practice (opens in a new tab) Checked on 17 November 2026.
- Australia and New Zealand refrigerant handling code of practice, part 2, 2025 edition (opens in a new tab) Checked on 17 November 2026.
- SKOPE: refrigeration and freezer troubleshooting (opens in a new tab) Checked on 17 November 2026.
- Food Standards Australia New Zealand: overview of food safety management tools, 1 October 2025 (opens in a new tab) Checked on 17 November 2026.
- Food Standards Australia New Zealand: Safe Food Australia, chapter 3.2.2 (opens in a new tab) Checked on 17 November 2026.
- Food Standards Australia New Zealand: storing food safely, updated 1 October 2025 (opens in a new tab) Checked on 17 November 2026.
- Food Standards Australia New Zealand: thermometers, updated 1 October 2025 (opens in a new tab) Checked on 17 November 2026.
- Food Standards Australia New Zealand: evidence tool, updated 1 October 2025 (opens in a new tab) Checked on 17 November 2026.
- Australian Government, energy.gov.au: refrigeration guide for businesses (opens in a new tab) Checked on 17 November 2026.
- Department of Climate Change, Energy, the Environment and Water: bench testing results of refrigeration and air conditioning equipment, October 2022 (opens in a new tab) Checked on 17 November 2026.
- Climate Control News: testing proves benefits of routine maintenance, 20 November 2022 (opens in a new tab) Checked on 17 November 2026.
- Heatcraft: installation and operations manual for condensing units, preventive maintenance guidelines (opens in a new tab) Checked on 17 November 2026.
- Heatcraft: preventive maintenance (opens in a new tab) Checked on 17 November 2026.
- SKOPE: user manual for the SC430N upright glass door fridge, February 2022 (opens in a new tab) Checked on 17 November 2026.
- True Manufacturing: installation manual TEC_TM_098 (opens in a new tab) Checked on 17 November 2026.
- Williams Refrigeration Australia: operating manual for upright and counter refrigeration, April 2020 (copy held by a reseller) (opens in a new tab) Checked on 19 November 2026.
Related pages
- Coolroom and commercial fridge repairs in East Gippsland
For equipment that has already failed.
- Commercial refrigeration maintenance checklist
Work out a service schedule for your own equipment.
- Cleaning commercial refrigeration: operator tasks and limits
The cleaning your own staff do between services.
Want your refrigeration on a schedule?
Send ABL your equipment list with an enquiry, or call and read it out.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.