Air-cooled, water-cooled or remote: how an ice machine should be cooled
Where each kind of ice machine sends its heat, the water and drains a water-cooled one needs, when each is the better choice, and a site sheet.
Last updated
For most hospitality venues an air-cooled ice machine is the better choice. It needs one water supply and one drain, and it uses a fraction of the water. A water-cooled machine suits a room that is too hot or too tight for air cooling, but unless its condenser water goes round a recirculating loop, it sends that water down the drain for as long as it makes ice. A remote condenser is the third option: it puts the heat and the fan noise outside and keeps the water use of an air-cooled machine.
How to use this guide
Step 1: See where the heat goes
Each arrangement, and what it needs at the machine.
Go to Where the heat goes
Where does each kind of machine put its heat?
Freezing water means taking heat out of it, and the machine has to get rid of that heat somewhere. The condenser is the part that does it. The three arrangements differ in where it sends the heat, and so in what the site has to provide.
| Arrangement | Where the heat goes | What the site provides |
|---|---|---|
| Air-cooled | Into the room, as warm air blown out of the machine. A mid-sized machine can give off more than 2 kW, and the maker's sheet gives the figure for sizing the room's air conditioning. | Clear air around the machine, a room that stays within its temperature range, one water supply, one drain and power. |
| Water-cooled | Into water that runs through the condenser and then to the drain, or back to a cooling loop. | A second water supply for the condenser and its own drain, as well as the ice-making water, its drain and power. |
| Remote air-cooled condenser | Outside, through a condenser on the roof or an outside wall, joined to the machine by refrigerant lines. | Indoors, the ice-making water, a drain and power. Outside, a place for the condenser within the maker's limits on line length and height. |
Which is the better choice for your site?
| Choose | When |
|---|---|
| Air-cooled | The room stays within the machine's temperature range through a summer service, there is clear air around the machine, and the heat it gives off will not make the room uncomfortable. That is most venues. |
| Remote condenser, on a modular head | The room is hot, tight or where guests sit, such as a bar or a dining room, and there is a roof or outside wall within the maker's line limits. |
| Water-cooled on a recirculating loop | The room is too hot or too tight for air cooling, and the building already has a chilled water loop or a cooling system the machine can join. |
| Water-cooled on mains water | Only where none of the others can work. The condenser water goes down the drain for the life of the machine. |
Air cooling does best where the room stays at about 27°C or below. In a 32°C room with 21°C water, most air-cooled machines make about 15 to 30 per cent less ice than at 21°C, and a machine's room range usually tops out at 38 to 43°C, depending on the model.
A self-contained machine, under a bench or upright, has its condenser inside its own cabinet. A remote condenser comes with a modular head on a bin, so for a self-contained machine the choice is between air and water cooling. To read a machine's output at a hot room's conditions, and the bin it needs, see the guide to sizing a hospitality ice machine.
Two kinds of water: the ice and the condenser
A water-cooled machine uses water in two separate ways, and a quote should give both figures:
- Water that becomes ice. Every machine uses it, plus the extra a cube machine rinses away each cycle to keep scale down. It runs from about 100 litres to over 400 for every 100 kg of ice, depending on how much the machine rinses and how clear the ice is. Recent cube machines are often between 120 and 200 litres.
- Water that cools the condenser. Only a water-cooled machine uses it. On one current model it is about 1,100 litres for every 100 kg of ice, around nine times the water that becomes ice, and warmer water means more of it.
Taken together, a water-cooled machine that sends its condenser water straight to the drain uses about 850 to 2,500 litres for every 100 kg of ice. An air-cooled machine uses under about 420.
Australia's minimum energy performance standard (opens in a new tab) for ice makers has a place for both figures, the potable water use rate and the condenser water use rate, but declaring them is up to the supplier. That is as at November 2026. Ask for both, for the model you are quoted.
The water that becomes ice has to be drinking water and goes through the machine's water filter. The condenser water does not become ice and is not usually run through the filter: check the manual for the model. For the filter, see the guide to choosing an ice-machine water filter.
Does a water-cooled machine cost less to run?
It uses less electricity and far more water. The water-cooled version of a machine usually draws 10 to 16 per cent less power than its air-cooled twin. The air-cooled version's heat also lands in the room, where air conditioning may have to remove it. Against that, a water-cooled machine on mains water sends its condenser water down the drain for as long as it makes ice. Which costs less on your site turns on:
- your water and sewerage charges, against your electricity price
- whether the condenser water goes to the drain or round a recirculating loop
- how warm your water is, because warmer water means more of it through the condenser
- how hot the room gets, and whether it is air-conditioned
Ask for each version's energy use and both water figures at 32°C air and 21°C water, and work out a year with your own tariffs. Neither kind is cheaper on every site.
Does a water-cooled machine keep up better in a hot room?
Often, but check the model. A water-cooled condenser does not depend on the room air, so its ice-making cycle stretches less as the room heats up. Yet the machine itself still stands in the room, and its manual can give it the same room range as the air-cooled version. Some water-cooled versions also lose as much output between the cool and hot ratings as their air-cooled twins, or more. Put the two versions' output at 32°C air and 21°C water side by side before you decide.
If a machine you already have is falling behind in summer, see the guide to an ice machine making less ice.
What does a remote condenser involve?
- Heat and noise go outside. The condenser and its fan move out of the room, which makes a bar or dining room cooler and quieter.
- The position is fixed by the lines. The refrigerant line run is usually limited to about 20 to 30 m, with the condenser up to about 10 m above the machine or 3 to 5 m below. The manual for the model sets the limit, so the outside position is settled before the machine is ordered.
- It needs clear air outside too. The manual sets the space around the condenser.
- It is a matched set. The machine, the lines and the condenser are made for each other and use the same refrigerant.
What upkeep does each kind need?
| Arrangement | What its upkeep involves |
|---|---|
| Air-cooled | The air filter is checked often and washed when it clogs, and a technician cleans and checks the condenser, usually every 6 to 12 months. Both clog faster in a greasy or dusty kitchen. |
| Water-cooled | No condenser air filter or fan to clean. In hard water the condenser scales up inside, and the sign is water use creeping up. Descaling it is a technician's job. |
| Remote condenser | The air-cooled upkeep, with the condenser outside on the roof or wall. Plan safe access to it for the technician. |
The ice-making water system needs cleaning and sanitising whichever way the machine is cooled. See the guide to ice-machine cleaning and sanitising.
What about a cooling tower or a chilled water loop?
This arises only where the building already has a loop, such as a large hotel, club or hospital. A water-cooled machine can run on a recirculating loop instead of mains water, so its condenser water is cooled and used again. The loop might be a building's chilled water system, a dry cooler or a cooling tower. That cuts the water to the drain sharply, and the manual for the model sets the flow and connections the loop has to provide.
Who does each part of the installation?
- Water supply. Installing any part of a cold water service connected to a drinking water supply is water supply work (opens in a new tab), a class of plumbing work in Victoria, for a licensed or registered plumber.
- Drains. The machine's drain, the bin drain and a water-cooled condenser's drain are usually run separately, ending above a floor drain with an air gap rather than piped straight to the sewer. That is the plumber's part.
- Power. A new power point or a hard-wired connection is electrical installation work (opens in a new tab), for a registered electrical contractor.
- The refrigerant circuit. Work on a circuit that holds a fluorocarbon refrigerant, such as the lines to a remote condenser, needs a refrigerant handling licence (opens in a new tab). Many newer machines use a hydrocarbon refrigerant, which is flammable, and WorkSafe Victoria (opens in a new tab) says technicians who work on them need to be competent to manage that hazard.
Site sheet for the installer
Who to talk to
We sell ice machines for hospitality venues. Send the site sheet with an enquiry from the ice machines page, with photos of where the machine would stand and, for a remote condenser, where the condenser would go.
Sources (17)
Checked on 20 November 2026
- United States Environmental Protection Agency: WaterSense at Work, commercial ice makers, February 2025 (opens in a new tab)
- United States Environmental Protection Agency: WaterSense at Work, single-pass cooling, 2012 (opens in a new tab)
- Federal Register of Legislation: Greenhouse and Energy Minimum Standards (Commercial Ice-makers) Determination 2025 (opens in a new tab)
- Hoshizaki: KM-590 air, water and remote cooled ice makers, instruction manual (opens in a new tab)
- Hoshizaki Australia: FM-150KE-N flake ice maker, installation manual (opens in a new tab)
- Hoshizaki America: remote condensers (opens in a new tab)
- Manitowoc: Indigo NXT iP0500 air and water cooled specification sheet, 2025 (copy held by a reseller) (opens in a new tab)
- Scotsman: Prodigy modular cuber technical service manual, 2015 (opens in a new tab)
- Scotsman: UC2024 and UC2724 user manual, maintenance, 2019 (opens in a new tab)
- Scotsman: CME1856W water-cooled modular cuber, product manual (opens in a new tab)
- Victorian Department of Health: cooling tower systems and the Public Health and Wellbeing Act 2008, updated 2 January 2025 (opens in a new tab)
- Victorian Department of Health: cooling tower systems, updated 16 April 2025 (opens in a new tab)
- Victorian Legislation: Plumbing Regulations 2018, version 010, 1 May 2026 (opens in a new tab)
- Energy Safe Victoria: electrical workers, reviewed 24 January 2025 (opens in a new tab)
- Australian Refrigeration Council: what work requires a refrigerant handling licence (opens in a new tab)
- WorkSafe Victoria: using flammable refrigerants (opens in a new tab)
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page.
Related pages
- Ice machine repairs and sales in Gippsland
Buying or repairing an ice machine, and what the site needs.
- Sizing a hospitality ice machine: production and storage
The output and bin your venue needs at hot-room conditions.
- Choosing an ice-machine water filter for the actual water supply
Matching a filter to the water that becomes ice.
Not sure which suits your room?
Send ABL the site sheet and photos of the spot with an enquiry, or call us.