Compare a commercial fridge's energy rating only with another cabinet of the same kind, size, temperature class and test room. Stars are optional on commercial cabinets, so ask for the two figures behind them: the tested energy use in kWh per 24 hours, and the energy efficiency index, which adjusts for size. The daily figure times 365 times the rate on your power bill gives a yearly running cost to set beside the price.

How to use this guide

  1. Step 1: Gather the figures

    Energy use, efficiency index, size and class for each cabinet.

    Go to The figures
  2. Step 2: Check they compare

    Same kind, temperature class, test room and size.

    Go to Like for like
  3. Step 3: Fill in the sheet

    Running cost and whole-of-life cost, side by side.

    Go to the record

What the energy figures on a commercial cabinet mean

Display cabinets, drinks cabinets and self-contained storage cabinets sold in Australia have to meet the minimum energy standard in the GEMS determination for refrigerated cabinets (opens in a new tab), and each model is registered before it can be supplied. Registration records these figures. Ask the supplier for them, or look the model up yourself.

The energy figures for a registered commercial cabinet
FigureWhat it isHow to use it
Energy use, kWh per 24 hoursThe electricity the cabinet used over a day in the test room. Some sheets call it total energy consumption.The base of a running cost. A bigger cabinet uses more, so on its own it does not show which is more efficient.
Energy efficiency index (EEI)The cabinet's yearly energy use as a percentage of a reference figure set for its kind and size. Lower is better.The fairest single number between two cabinets of the same class. To be sold, a display cabinet has to score under 130, a heavy duty storage cabinet under 115, and a light or normal duty storage cabinet under 95.
Stars, 1 to 10Optional. If a supplier quotes stars, they have to be worked out from the EEI: 10 stars is an EEI under 12, 1 star is 100 to 130.A simpler form of the EEI. A cabinet with no stars on show can still be registered and legal to sell.
Net volume or display areaThe size the rules rate the cabinet on: net volume in litres for a storage cabinet, total display area in square metres for a display cabinet.Where sizes differ, compare the EEI. Energy per litre or per square metre is only a rough check.
Temperature class and test roomHow cold the test packs stayed, such as M1 or L1, and the climate class of the room the energy was measured in.The two things that have to match before the other figures mean anything. The guide to commercial fridge climate classes explains them.

To check a model, ask for its registration number and look it up in the Energy Rating Registration Database (opens in a new tab). The same records are published as open data (opens in a new tab), where each registered cabinet shows its energy use, EEI, stars, temperature class, the climate class of each test and its size.

Does every commercial fridge carry an energy star label?

No. A commercial cabinet does not have to show an Energy Rating Label. The minimum energy standard is compulsory, and the star rating is voluntary. Energy Rating says a star rating is calculated when a model is registered and recorded in its database, so a model's stars can be found even when the cabinet in the showroom shows none. It also says to compare star ratings only between cabinets of the same type, size and operating temperature (opens in a new tab).

Some cabinets are outside the rules and carry no rating, such as pass-through cabinets, remote storage cabinets and open-top preparation tables. The guide to commercial fridge climate classes lists them. For those, ask the maker for the energy figure and how it was measured. A used cabinet is outside the supply rules too, and it may have been built to an older, less efficient standard.

When are two energy figures comparable?

Two energy figures compare only when the tests behind them match. These are the usual mismatches, and what to do about each.

Mismatches that make two energy figures unfair to compare
MismatchWhy it skews the comparisonWhat to do
A display cabinet against a storage cabinetThey are tested to different standards, against different reference figures, and display cabinets are rated on display area, not volume.Compare display with display and storage with storage.
A fridge against a freezer, or M1 against M2Fridges and freezers are rated against different reference figures, and a drinks cabinet tested to M2 is not doing a food fridge's job.Match the temperature class first.
A class 3 test against a class 4 testNormal and heavy duty storage cabinets have their energy measured in a 30°C room, light duty and display cabinets in a 25°C room. Figures from different test rooms do not line up.Check the climate class of the energy test in the register.
Different sizesA bigger cabinet uses more energy and may still be the more efficient one for each litre it holds.Compare the EEI, and compare cabinets of a similar size where you can.
A remote cabinet against a self-contained oneA remote display cabinet's figure is its own fans, lights and heaters plus a refrigeration share worked out by the test standard. It is not a measurement of the plant on your site. A self-contained cabinet's figure includes its own compressor.Compare remote with remote, and ask what the refrigeration plant itself will use.
A figure from an older rule, another country or a maker's own testTest routines differ in door openings, lighting and test room, and the differences are large: door-opening rules alone can change a result by up to 150%.Ask which standard and which version the figure was measured to. Compare Australian registered figures with each other.

Then ask whether the cabinet is the right size at all. A smaller cabinet that holds what you stock can cost less to run than a bigger, better rated one that runs half empty.

How to work out a yearly running cost

Multiply the energy use in kWh per 24 hours by 365, then by the usage rate per kWh on your own power bill. A cabinet tested at 4 kWh a day uses about 1,460 kWh a year in the test room. If your tariff has peak and off-peak rates, a cabinet runs through both, so use the rates in proportion or the higher one for a cautious figure, and write down which you used. Some sheets print a yearly cost: check the rate it assumes before you rely on it.

The tested figure is a starting point, not a forecast. A cabinet uses more than its test figure when:

  • the room is hotter than the test room, or the cabinet is in sun or beside an oven or grill. As a rough guide, each degree hotter adds about 2% for a fridge and 5 to 6% for a freezer
  • the thermostat is set colder than the food needs: roughly 2% more for each degree on a fridge, and 4 to 6% on a freezer
  • it is overstocked, or stock blocks the air grilles
  • warm stock goes in, or product warms up on its way from the delivery to the cabinet
  • doors are opened often or left open, or the door seals are worn
  • the condenser is dirty
  • the lights and anti-condensation heaters stay on after hours
  • the defrost settings do not suit how the cabinet is used

Most of those are in your hands, and regular cleaning and servicing keeps the rest in check: see our commercial refrigeration maintenance page. To compare a new cabinet with the one you have now, meter what the existing cabinet actually uses. That baseline is a fairer comparison than its old sheet.

Comparing the cost over the cabinet's life

The cheapest cabinet to buy can cost more to own. Add up the whole-of-life cost for each option:

  • the purchase price, including GST, and delivery
  • installation, including any electrical work, such as a dedicated power point
  • running cost: the yearly figure times the years you expect to keep it
  • maintenance: condenser cleaning, seals, and the servicing the warranty asks for
  • disposal at the end: the refrigerant has to be removed by a qualified technician before the cabinet is scrapped

For the number of years, about 10 is a fair planning figure. The ATO depreciates commercial fridges and freezers over 10 years, and United States government guides assume 12. That is a planning figure, not a promise of how long a cabinet will last: duty, the room and maintenance decide that.

Keep the comparison honest. A difference in running cost depends on your tariff, your room and how the cabinet is used, so treat a supplier's saving figure as an estimate and ask how it was worked out. Where you are weighing a repair to old equipment against a new cabinet, the guide to comparing repair cost with energy and stock-loss risk covers the rest of that decision.

Like-for-like energy comparison sheet

Like-for-like energy comparison

Fill in a part for each cabinet. Leave a gap where a figure is missing, then ask the supplier for it. Copy it or print it.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

Your assumptions

Cabinet 1

Cabinet 2

The comparison

Who to call

We supply, install and service commercial refrigeration for businesses in Bairnsdale and East Gippsland. Our commercial refrigeration equipment supply page explains how to ask for a quote: send the comparison sheet with your enquiry. When the quotes differ in more than the cabinet, the guide to comparing commercial refrigeration quotations helps you line them up.

Sources (21)

Comparing cabinets on running cost?

Send ABL your comparison sheet with an enquiry, or call and read out the models.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.