Repair or replace commercial refrigeration: weighing cost, energy and stock risk

Weigh a commercial fridge or coolroom repair against replacement: the quote, condition, parts, energy, downtime and stock at risk, with a worksheet.

Last updated

Weigh a repair against a replacement on the same written inputs: the repair quote, the condition and history of the equipment, parts, the full replacement cost, energy, and what downtime and lost stock would cost you. As a rule of thumb, replacement is usually the better value when a repair costs more than half the price of new equipment.

How to use this guide

  1. Step 1: Gather the inputs

    The repair quote, condition, history, parts, replacement cost, energy, downtime and stock.

    Go to Decision inputs
  2. Step 2: Fill in the worksheet

    Put both options side by side and mark how sure you are of each figure.

    Go to the record
  3. Step 3: Call

    Go through the worksheet with us before you commit to either option.

    Call (03) 5153 2650
What usually tips it
What you findWhat it points to
One failed part with a confirmed cause, on equipment that is otherwise soundRepair.
Parts in stock, coils and cabinet in good condition, and a first real faultRepair.
The same fault back after repairsUsually replacement.
A failed compressor or a refrigerant leak, on equipment that is also wornUsually replacement.
A controller or other key part no longer made, with no equivalentReplacement, or new plant where the room or the cabinet body is sound.
The body or the panels in poor conditionReplacement.
The business has outgrown itReplacement is the chance to fix that.
The repair costs more than half the price of new equipmentReplacement is usually the better value.

Most cases sit somewhere in between, and that is what the worksheet is for. Mark each input as quoted, measured, estimated or unknown, because an unknown input is a question to ask before you decide.

What goes into a commercial fridge repair or replace decision?

Each input comes from somewhere you can point to. Write down where it came from and how sure it is. The worksheet at the end of this guide holds them all.

Inputs to a repair or replace decision
InputWhere it comes fromHow sure it usually is
The repair scope and priceThe written repair quote: the fault found, the parts and the labour.Quoted, once it is in writing.
Repair historyService reports, the logbook if the system has one, and your own notes of faults.Recorded or remembered. Say which.
PartsThe technician or the supplier: in stock, on order, or no longer made.Confirmed only once a date is given.
Replacement costA written quote for the whole job, not only the equipment.Quoted, or an estimate until the quote arrives.
EnergyA meter on the existing equipment, and the tested figure on the specification of a replacement.Measured, tested or unknown. The two are different kinds of figure.
Stock and trade at riskYour own records: what the equipment holds and what a day without it costs.Your figure. Only you know it.

Does the age of the equipment decide it?

Not on its own. The year of manufacture is on the identification plate, sometimes coded into the serial number, so write it down. The federal government's refrigeration guide for businesses (opens in a new tab) says a system more than 10 years old should be considered for replacement, and that an efficient new system could save up to 30% in energy use. Treat that as a reason to run the comparison, not as a cut-off. The condition of the equipment and its repair history matter as well.

What should the repair quote tell you?

A quote you can weigh says more than a price. Ask for it in writing, with:

  • the fault found, and how it was confirmed
  • the parts, whether each one is original or an equivalent, and whether it is in stock or on order
  • what else is replaced along with the main part, and why
  • whether a refrigerant leak was found. A system that has lost refrigerant is not recharged until the leak is found and repaired, so a leak can widen the job.
  • how long the equipment will be out of service, and what that depends on
  • what the quote leaves out

Evidence of condition

Ask the technician to note the condition of what is not being repaired: the coils, the fans, the controller, any rust on the cabinet or the unit, the door seals and, on a coolroom, the panels and the door. Photos help when you compare later. What you see day to day counts too: ice building up, water on the floor, a door that does not close, a new noise. The repairs page lists the warning signs and their usual causes.

Repair history

Gather the service reports for the last few years and your own notes of each fault: the date, what happened and what was done. ABL's service reports record the temperatures, the work done and the parts replaced. A system with more than 3 kg of refrigerant should have a logbook, which records repairs, replaced components and any refrigerant added. Refrigerant is not used up, so refrigerant that has had to be added points to a leak, or to a short charge when the system was installed. A fault that keeps coming back after repairs weighs more than one old fault that was fixed for good. For a fault that comes and goes, see the guide to recording intermittent faults.

What should a replacement figure include?

Compare the repair against the cost of the whole replacement job, not the price of the equipment alone. A replacement quote should say who does each of these, and whether it is included:

  • the equipment, and delivery to where it will stand, including the way in through doors and corridors
  • taking away the old equipment. Any scheduled refrigerant in it has to be recovered when it is decommissioned, and that is licensed work.
  • electrical work. Some cabinets need a dedicated circuit, and remote plant needs its own power supply. In Victoria, fixed electrical installation work needs a licensed electrician, as Energy Safe Victoria (opens in a new tab) sets out.
  • a drain, where the new equipment needs one. Remote cabinets usually do, and so do some self-contained ones.
  • for a coolroom or remote plant, the pipework, where the condensing unit goes, and commissioning
  • what happens to your stock during the changeover

To line up two replacement quotes item by item, see the guide to comparing commercial refrigeration quotations.

Replacement assumptions that stay uncertain

Some inputs stay uncertain even with a quote in hand. Write them down as assumptions rather than leave them out:

  • Energy use on your site. A tested figure comes from a test room, not your kitchen or shop.
  • Lead time. A delivery date is an estimate until the equipment is on its way.
  • How long the new equipment will last. Treat any figure as an assumption, not a fact.
  • Parts support. How long parts will be available for the new model. The parts section below has the questions to ask.

How do you compare energy efficiency fairly?

New equipment is generally more energy efficient and can be cheaper to run, but how much cheaper on your site depends on what you are comparing. Measure what you can, and compare like with like.

Energy figures and what each one tells you
FigureWhat it isWhat it does not tell you
Metered use of the existing equipmentWhat it actually uses on your site, in your conditions. A sub-meter on its circuit gives you a baseline over days and seasons.What a new unit would use. Fitting a sub-meter is fixed electrical work, so a licensed electrician does it.
The tested figure for a new cabinetIts energy consumption over 24 hours, in kWh, measured under the GEMS determination (opens in a new tab) in a test room at a set climate class.What it will use where you put it, with your heat, humidity and door openings.
Performance data for coolroom plantThe maker's capacity and power figures at stated operating conditions.How it will perform in your room, unless the conditions match your room temperature and the air around the condensing unit. Ask about part-load performance as well as full load.
An estimateA figure worked out from running time or the rating plate.Measured use. Mark it as an estimate in the worksheet.

Compare a replacement cabinet's tested figure only with another cabinet built for the same job: display against display, storage against storage, at the same temperature and climate class, and of a similar size. Display and storage cabinets are separate product classes under the GEMS determination, and they can be tested in different conditions. The guides to comparing energy ratings and running costs and climate classes go further.

The "up to 30%" saving in the age section is a ceiling for systems in general, not a forecast for yours.

What can change the energy picture before you decide?

Part of a high energy bill can come from around the equipment rather than its age: a dirty condenser, worn door seals, overstocking, blocked air grilles, heat and sun, lights and anti-condensation heaters left on after hours, and thermostat or defrost settings that no longer suit the conditions. Ask us to look at the settings and the condenser at a service, then see whether the readings change before you compare.

Downtime and stock: what would a failure cost you?

Neither quote includes the cost that often matters most: what happens to your business while the equipment is down. Put your own figures on it.

  • Stock exposure. What the equipment holds on a full day, and what that stock would cost to replace.
  • Trade lost. The sales you cannot make, or the dishes you cannot serve, for each day it is out.
  • Somewhere else for the stock. Spare cold space on site, a hired coolroom or another business. Each has a cost and a limit.
  • Staff time. Moving stock, measuring temperatures and throwing out what cannot be kept.
  • The chance of another failure. A repeat fault in the repair history raises it. A repair that fixes the cause lowers it.

Downtime differs between the options. A repair keeps the equipment out of service until the parts arrive and the work is done. A replacement can be planned for a quiet day, but it still takes delivery, installation and commissioning, and on a coolroom the room is out of use while the plant is changed. A breakdown chooses its own time.

What to do with stock when refrigeration fails is a food safety decision for your business and its food safety procedure. A repair or a new unit does not settle it. The repairs page covers what to do, and the guide to a commercial refrigeration contingency plan helps you plan for it.

Can you replace the refrigeration plant and keep the room?

On a walk-in coolroom or freezer room, the plant (the condensing unit, the evaporator and their controls) can be replaced while the insulated room stays. Whether that makes sense depends on the room as much as the plant.

New plant only, or a new room as well
What to look atPoints to keeping the roomPoints to rebuilding it
PanelsFlat, sound skins with no bulging, punctures or rust.Bulging panels, which can mean water has got into the insulation and frozen, and that greatly reduces the room's efficiency. Damage or water across much of the room counts against reusing the panels.
Joints, seals and pipe entriesJoints, the base of the panels and the holes for pipes are sealed, or can be sealed again.Gaps throughout the room. Even small gaps let warm, moist air in.
InsulationPanels thick enough for the temperature the room runs at.Panels too thin for the temperature the room now has to hold, such as a coolroom being turned into a freezer room. Thinner panels in sound condition are not by themselves a reason to rebuild.
Size and useThe room still suits the business: its size, its temperature and the way stock moves.The business has outgrown it or needs a different temperature. Turning a coolroom into a freezer room usually needs thicker panels and an insulated floor.
Time out of useUsually shorter: the room stays and the plant is changed.Longer: the room is taken down and rebuilt, and stock goes elsewhere for the whole job.

If the room stays, the new plant is matched to it: the temperature, the size of the room and the load that goes into it. A coolroom and a freezer room need different evaporator, compressor, defrost and control set-ups, and the refrigerant chosen affects which components are compatible. So ask the quote to say which existing parts stay, such as the evaporator, the pipework or the controls, and why they suit the new plant. A new system is best designed as a whole, so question any part kept only because it is already there.

For a new or rebuilt room, see coolroom and freezer room installation.

What if the replacement cabinet uses a different refrigerant?

A new cabinet may well use a different refrigerant from the one it replaces. That is not a problem in itself. The new cabinet is built and tested for its own refrigerant, which is shown on its identification plate, with a flame symbol when the refrigerant is flammable. Compare whole cabinets on the inputs in this guide, such as the duty, the tested energy figure, parts support and who can service it, not on the refrigerant alone.

Refrigerants are not interchangeable

What does not work is treating refrigerants as interchangeable in existing equipment. Under the refrigerant handling code of practice (opens in a new tab) (2025 edition), a change of refrigerant in an existing system follows the procedure in the standard for it. The code asks for advice on suitability from the equipment maker and the refrigerant and lubricant makers, and requires a refrigerant compatible with every part it touches, a new filter drier and new labels. A change to a more hazardous class of refrigerant needs the system re-engineered. And a system must not be charged with a refrigerant of higher global warming potential than the one it was designed for, apart from limited exceptions. So converting old equipment is a planned conversion, not a part swap. If it is offered, put it in the worksheet as an option of its own, with its own quote.

Ask who can service the new cabinet. Tools used on a flammable refrigerant have to be rated for its flammability grade, so check that your service provider works on the refrigerant shown on the plate of the new cabinet.

Does the refrigerant in your old equipment decide it?

No. Under the HFC phase-down (opens in a new tab), existing equipment is not affected and consumers do not have to replace it. For equipment built for an older ozone-depleting refrigerant, the Australian Refrigeration Council's fact sheet (opens in a new tab) says it does not need to be decommissioned or retrofitted and can still be serviced, and also that spare parts might become harder to source as it ages. Weigh the refrigerant with the other inputs, not ahead of them.

How do you compare replacement compressors?

When a compressor fails, a quote may offer a choice of replacement compressors, or a compressor against new plant or new equipment. Compare them as part of the whole system, not by the label on the compressor.

  • Confirm it has failed, and why. A compressor can be blamed for a fault that lies elsewhere: in the supply voltage, the wiring, a low refrigerant charge or a blockage in the system. Ask how the fault was confirmed and what caused it. We look for the cause before anything is replaced.
  • A compressor is matched to its system. Its capacity and power draw depend on the conditions it runs at, and it works with the evaporator, the condenser, the expansion valve, the controls and the refrigerant around it. Two compressors with similar labels can perform differently in your system.
  • Ask for figures at your conditions. The capacity and power draw at your room temperature and at the air temperature around the condensing unit, and the performance at part load.
  • Count the whole job. A compressor change usually comes with a new filter drier, and often a new contactor and capacitor. Recovering the refrigerant and charging the system again is part of the price, and on a system with a scheduled refrigerant it is licensed work.
  • Efficiency. Compressors use the most energy in a refrigeration system, so the efficiency of the replacement matters. Newer compressors, fans and controls with inverter drives can hold a steadier temperature.

So ask for a whole-system assessment: the condition of the coils, fans, controls and pipework, the refrigerant charge and any leaks, and whether the system still suits the job. The choice is then between a compressor in a sound system, new plant, or new equipment, and you can put each one through the worksheet.

Parts: before you buy, and when they run out

Spare parts: what to ask before you buy

Parts support is part of what you are buying. Do not assume every part will be held locally, or kept for the life of the equipment. Under the Australian Consumer Law, when a consumer buys a product, the manufacturer or importer must provide spare parts and repair facilities for a reasonable time after purchase, unless the consumer is told at the time of purchase that they will not be available after a certain time. A business can be a consumer too, depending on the price and the kind of product, and the ACCC explains when (opens in a new tab). Before you buy, ask:

  • Which parts are made for this model only, such as the controller or the display, and which are standard parts?
  • Where are parts held, and how long do they usually take to arrive?
  • Has the supplier said how long parts and repairs will be available? Ask for it in writing.
  • Who can service it in your area, including its refrigerant?
  • Does it come with a manual that lists its parts?

When the equipment or a part is no longer supported

A part that is no longer made does not by itself mean the equipment has to go. It means the options change, and each one needs its own quote in the worksheet.

Options when a part or a model is no longer supported
OptionWhen it can suitWhat to ask
An equivalent or universal partWhere a part from another maker matches the original's rating and fit. Some controllers, for example, are made as universal replacements for many models.What it was matched on, and whether anything else has to change with it.
Converting to a different refrigerantWhere the equipment maker supports it. See the refrigerant section above.What has to change, and who does the engineering.
New plant, keeping the room or the cabinetA coolroom or remote cabinet whose room or body is sound.The questions in the section on keeping the room.
New equipmentThe body is worn, the parts have run out, or the business needs something different.The full replacement cost, the lead time and the parts support.

Older equipment can keep running while it is sound. If the controller or another key part is no longer made, ask us whether an equivalent exists before it fails, and write the answer in the worksheet. Then a breakdown does not make the decision for you.

Repair or replacement worksheet

Repair or replacement worksheet

Fill in one worksheet for each piece of equipment, with both options side by side. Mark how sure each figure is, and leave a field blank rather than guess.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The equipment

Equipment

Option A: repair

How sure is the repair cost
Parts for the repair

Option B: replacement

What would be replaced
How sure is the replacement cost
Same duty as the old equipmentType, temperature, climate class and size

Energy

How the existing energy use was found

Downtime and stock

How sure are the stock and trade figures

Decision

Decision

Next step

Call ABL with the worksheet in front of you, or send it with an enquiry. For a fault now, start with the repairs page. For a replacement cabinet, see commercial refrigeration equipment supply, and for a coolroom, coolroom and freezer room installation. If the equipment keeps failing between services, the maintenance page covers planned servicing.