Commercial refrigeration equipment supply in Gippsland
ABL supplies commercial refrigeration equipment in Gippsland. How to describe the duty and the site, and what a supply quote should set out line by line.
Send an enquiry with the equipment brief on this page, or call ABL and talk it through. Start from what the equipment has to do, not from a model: what it holds, how much, how cold, and the room it stands in. Then measure the space and the way in.
How an equipment enquiry runs
Step 2: Know what the quote covers
Supply, delivery, installation, start-up, the old unit and warranty.
Go to Quote lines
What ABL supplies
ABL supplies commercial refrigeration equipment, such as fridges, freezers and display cabinets, to businesses across Gippsland from Bairnsdale, and installs refrigeration for restaurants and hospitality venues. Tell us the duty and the site, and ask us to quote delivery, placing, installation and removal of the old unit as separate lines.
- For a walk-in coolroom or freezer room, see the coolroom and freezer room installation page.
- For an ice machine, see the ice machines page.
- For refrigeration across a whole venue, see the hospitality refrigeration page.
- For equipment you already have that is not holding temperature, see the coolroom and commercial fridge repairs page.
Start with what the equipment has to do
Two cabinets that look alike can be built for different jobs. These are the questions we ask first, because the answers decide what will work.
| What to tell us | Why it matters |
|---|---|
| What it holds | Chilled food, frozen food, drinks or flowers. A drinks cabinet is designed for non-perishable drinks only and is tested to a warmer class than a food cabinet, so it is not the place for food. |
| Storage, display or preparation | A storage cabinet keeps stock for staff. A display cabinet lets customers see and reach it. A preparation counter holds pans for the line. Each is built for its job. |
| How much, and in what | The volume at your busiest, and the pans, trays, crates or cartons it goes in. Many kitchen cabinets are built around standard gastronorm pan sizes. |
| Whether anything goes in warm | A storage cabinet is built to hold food that is already cold. For food that has to be cooled from hot, a blast chiller is the equipment built for the job. |
| The room it stands in | A cabinet is rated for a test room of a set temperature and humidity, called its climate class. The common ones are class 3 at 25°C, class 4 at 30°C and class 5 at 40°C. A hot kitchen needs a cabinet rated for one. |
| How it is used | How often the doors open in a busy hour, who uses it, and how long it runs each day. |
The rating plate on a cabinet names its refrigerant. Many new plug-in cabinets use a hydrocarbon, which is flammable. WorkSafe Victoria (opens in a new tab) says the occupier or person in charge of the premises, which for a venue is the business, should ensure that only competent workers work on refrigeration, particularly systems with a flammable refrigerant.
The guides cover the choice of format in detail: choosing a commercial fridge format, glass-door or solid-door refrigeration, open multideck or glass-door displays, remote or self-contained display refrigeration, choosing a refrigerated preparation counter and commercial fridge climate classes.
Plug-in or remote: who installs what
A plug-in (self-contained) cabinet has all its refrigeration inside it. A remote cabinet is sold without its condensing unit, which sits somewhere else and is joined to it by refrigerant pipes. That one difference changes who does what.
| Part of the job | Plug-in cabinet | Remote cabinet or split system |
|---|---|---|
| Refrigeration | No work on the refrigerant circuit on site. The refrigerant code of practice treats installation as normally the buyer's job, following the maker's instructions. | The condensing unit is sized, chosen and installed by the refrigeration trade, and the pipework is run on site. That needs a refrigerant handling licence. |
| Power | Its own power point, plugged straight in, not into an extension lead or a power board. | The cabinet, and a separate supply for the condensing unit. |
| Drain | As the manual for the model sets out. | A connection to a drain, or a tundish. |
| Start-up | Run empty until it reaches temperature, then loaded. | Commissioned by the installer. The installer hands over the operating and maintenance instructions, the commissioning data and the test certificates. |
The Australian Refrigeration Council (opens in a new tab) says installing and commissioning equipment that holds a scheduled refrigerant, or will be charged with one, needs a refrigerant handling licence, whether or not the refrigerant is in it yet, as its refrigerant handling code of practice (opens in a new tab) also sets out. In Victoria a new power point or circuit is electrical installation work, done by a licensed electrician who gives you a Certificate of Electrical Safety, as Energy Safe Victoria (opens in a new tab) sets out.
What a supply quote should set out
The price of a cabinet is not the price of a working cabinet in your kitchen. Ask us for each of these as its own line, so you know what is in and what is not.
| Line | What to ask us to set out |
|---|---|
| The equipment | Make, model and quantity, with the temperature range, the climate class, the energy use in kWh per 24 hours and the refrigerant. |
| Delivery | To where, and what access it assumes. Carriers can charge extra where access is hard. |
| Placing and setting up | Unpacking, moving it into place, levelling it and taking away the packaging. |
| Installation | For a remote cabinet or a room: the condensing unit, the pipework and the drain, by a licensed refrigeration technician. |
| Electrical work | Any new power point or circuit, by a licensed electrician, or a note that it is excluded. |
| Start-up and handover | Running it to temperature before stock goes in, and the paperwork you are given. |
| The old equipment | Whether it is taken away. Before an old cabinet is scrapped, a licensed person has to recover any scheduled refrigerant from it. |
| Warranty | How long the maker's warranty runs and what it asks of you. Who does warranty work near you, and whether travel and after-hours call-outs are covered. |
| The price | The total, including GST. |
Makers' warranties on cabinets run from about one year to five, depending on the maker and the range. Common conditions are that the condenser is cleaned as the manual says, the cabinet has the ventilation it needs, and the room stays within the maker's highest approved temperature. Door seals, glass and lights are often excluded. Some makers' terms limit free warranty travel to a set distance from their service agent, which matters in country Gippsland.
To line two quotes up against each other, see the guide to comparing commercial refrigeration quotations.
Getting it in, and the first day
| What to plan for | What to do |
|---|---|
| The way in | The route is yours to provide. Measure the narrowest doorway, the tightest corner and any steps, and check them against the packed size of the cabinet. |
| Where it stands | Out of direct sun and away from ovens, grills and heaters, on a level floor, with the clearance the manual gives. That ranges from nothing at the sides of some cabinets to about half a metre above a top-mounted unit. |
| Standing time | If the cabinet was tilted or laid down in transport, it usually stands upright for a few hours before it is switched on. Some makers ask for 24 hours every time. |
| Running it empty | It runs empty until it reaches temperature before stock goes in: from about an hour to a day, by maker. Makers' warranties generally exclude lost stock. |
| Checking it | The display shows the air or coil temperature. Check the food with a probe thermometer once it is loaded. |
The manual for the model governs every one of these.
Energy rules and running costs
- Minimum energy standards apply. Refrigerated cabinets fall under the refrigerated cabinets energy rules of 2024 (opens in a new tab), in force from 5 October 2024. A model has to be registered before it can be supplied. That is as at November 2026.
- A star label is optional. An energy rating label is not mandatory (opens in a new tab) for cabinets, so a missing label does not mean a poor cabinet. Compare the energy use figure instead.
- Compare like with like. The figure is in kWh per 24 hours, measured in a test room. Compare cabinets of the same kind, size and climate class.
- Work out the running cost. Multiply the kWh per 24 hours by 365, then by the rate per kWh on your power bill.
For the working, see the guide to comparing commercial refrigeration energy ratings and running costs.
Your rights when a business buys equipment
A business is covered by the consumer guarantees (opens in a new tab) when what it buys costs less than $100,000 including GST, or is the kind of thing commonly bought for household use. The consumer guarantees do not cover goods bought to resell, or to be used up or transformed in production. That is as at November 2026.
- Acceptable quality. Safe, durable, free from defects and able to do what similar products are commonly used for.
- Fit for the purpose you made known. This is why the duty is worth putting in writing with your enquiry.
- A maker's warranty is extra. The ACCC says a warranty against defects (opens in a new tab) does not limit or replace the consumer guarantees, and they can last longer than it.
Looking at second-hand equipment?
- The energy rules do not apply. A second-hand product (opens in a new tab) can be resold without being a registered model, so it may use more power than a new one.
- The consumer guarantees still apply, with limits. A used item sold by a business still carries them, judged against its age, price and condition. Private sales and auctions carry very few (opens in a new tab).
- The maker's warranty may stay behind. A maker's warranty can be limited to the first user at the first site, so ask.
- Check the refrigerant. The plate names it. New R22 equipment can no longer be made or imported, and the Australian Refrigeration Council (opens in a new tab) says imports of R22 gas end entirely on 1 January 2030.
- Age. For tax, the effective life (opens in a new tab) set for refrigeration cabinets in hospitality and retail is 10 years. That is a depreciation figure, not a promise of how long one lasts.
- A used coolroom. A modular coolroom can be taken down and moved to a new site. See the guide to planning a modular coolroom relocation.
Your equipment brief
Towns ABL covers
ABL is based in Bairnsdale and supplies businesses across Gippsland, so tell us where the equipment is going. A town with a link has its own page.
- Bairnsdale
- Benambra
- Bruthen
- Buchan
- Cann River
- Churchill
- Eagle Point
- Ensay
- Heyfield
- Lake Tyers
- Lakes Entrance
- Lindenow
- Maffra
- Mallacoota
- Marlo
- Metung
- Moe
- Morwell
- Nowa Nowa
- Omeo
- Orbost
- Paynesville
- Sale
- Stratford
- Swan Reach
- Swifts Creek
- Traralgon
If your town is not here, call and ask. See also service areas.
Sources (31)
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page. Checked on 20 November 2026.
- ABL Refrigeration: service areas (opens in a new tab) ABL's own page. Checked on 20 November 2026.
- Federal Register of Legislation: Greenhouse and Energy Minimum Standards (Refrigerated Cabinets) Determination 2024 (opens in a new tab) Checked on 19 November 2026.
- Energy Rating: refrigerated cabinets, industry information (opens in a new tab) Checked on 17 November 2026.
- Federal Register of Legislation: Greenhouse and Energy Minimum Standards Act 2012, compilation of 5 December 2025 (opens in a new tab) Checked on 19 November 2026.
- SKOPE: GEMS overview, climate and temperature classes (opens in a new tab) Checked on 19 November 2026.
- Australia and New Zealand refrigerant handling code of practice, part 1, 2025 edition (opens in a new tab) Checked on 19 November 2026.
- Australia and New Zealand refrigerant handling code of practice, part 2, 2025 edition (opens in a new tab) Checked on 19 November 2026.
- Australian Refrigeration Council: what work requires a refrigerant handling licence (opens in a new tab) Checked on 19 November 2026.
- Australian Refrigeration Council: fact sheet 09, recovering refrigerant from end-of-life equipment (opens in a new tab) Checked on 19 November 2026.
- Australian Refrigeration Council: fact sheet 26, R22 gas and equipment (opens in a new tab) Checked on 19 November 2026.
- Energy Safe Victoria: electrical workers, reviewed 24 January 2025 (opens in a new tab) Checked on 19 November 2026.
- Energy Safe Victoria: Certificates of Electrical Safety for the community, reviewed 17 September 2026 (opens in a new tab) Checked on 19 November 2026.
- WorkSafe Victoria: using flammable refrigerants, reviewed 30 October 2024 (opens in a new tab) Checked on 19 November 2026.
- ACCC: consumer rights and guarantees (opens in a new tab) Checked on 19 November 2026.
- ACCC: warranties, for business (opens in a new tab) Checked on 19 November 2026.
- ACCC: consumer guarantees, a guide for businesses and legal practitioners (opens in a new tab) Checked on 19 November 2026.
- Federal Register of Legislation: effective life of depreciating assets determination 2025 (opens in a new tab) Checked on 19 November 2026.
- Williams Refrigeration Australia: operating manual for upright and counter refrigeration, July 2025 (opens in a new tab) Checked on 19 November 2026.
- Williams Refrigeration Australia: price guide 22D (opens in a new tab) Checked on 19 November 2026.
- Bromic: upright fridge and freezer user manual, January 2026 (opens in a new tab) Checked on 19 November 2026.
- Bromic: underbench range user manual, 2022 (opens in a new tab) Checked on 19 November 2026.
- Bromic: Extra Care warranty (opens in a new tab) Checked on 19 November 2026.
- Hoshizaki: undercounter refrigerator and freezer RT and FT series, instruction manual (opens in a new tab) Checked on 19 November 2026.
- SKOPE: user manual for the SC430N upright glass door fridge, February 2022 (opens in a new tab) Checked on 19 November 2026.
- SKOPE: warranty terms and conditions, updated 1 October 2026 (opens in a new tab) Checked on 19 November 2026.
- True Manufacturing: STR, STA and STG series installation manual, 2026 (opens in a new tab) Checked on 19 November 2026.
- SKOPE: BME600N-A specification sheet (opens in a new tab) Checked on 19 November 2026.
- Tefcold: gastronorm size guide (opens in a new tab) Checked on 19 November 2026.
- Food Standards Australia New Zealand: thermometers and using them, updated 25 February 2025 (opens in a new tab) Checked on 19 November 2026.
- Williams Refrigeration Australia: the risks of cooling without a blast chiller (opens in a new tab) Checked on 19 November 2026.
Related pages
- Comparing commercial refrigeration quotations
Line up two quotes that include different things.
- Upright, underbench, drawer or roll-in: choosing a commercial fridge format
Pick the format for each station.
- Comparing commercial refrigeration energy ratings and running costs
Compare energy figures fairly and work out a running cost.
Buying refrigeration equipment?
Send ABL your equipment brief with an enquiry, or call and talk through what it has to do.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.