Commercial fridge climate classes: what the rating means for your room
What a commercial fridge's climate class and temperature class mean, how to check them against your room, and what to ask the supplier before you buy.
Last updated
A climate class is the room a commercial fridge was tested in. Under the Australian rules, class 3 is a test room at 25°C and 60% relative humidity, class 4 is 30°C and 55%, and class 5 is 40°C and 40%. The code beside it, such as M1 or L1, is the temperature class: how cold the test packs stayed in that room. Read the two together, then hold them against the hottest your own room gets.
How to use this guide
Step 1: Measure the room
The hottest temperature and the humidity where the cabinet will stand.
Go to Measuring your roomStep 2: Read the paperwork
The climate class, temperature class and duty, from the sheet and the register.
Go to Supplier documents
What does a climate class mean?
Display and storage cabinets sold in Australia come under the GEMS determination for refrigerated cabinets (opens in a new tab), the federal rule that sets their energy standards and how they are tested. Each test is run in a room held at a set temperature and humidity, and the climate class names that room. It is a test condition, and it is not the same thing as the highest room temperature the maker allows.
| Class | Test room | Where it is used |
|---|---|---|
| Class 3 | 25°C, 60% relative humidity | Every display cabinet and drinks cabinet is tested here. A light duty storage cabinet holds its temperature class here. |
| Class 4 | 30°C, 55% relative humidity | A normal duty storage cabinet holds its temperature class here. |
| Class 5 | 40°C, 40% relative humidity | A heavy duty storage cabinet holds its temperature class here, in every compartment, without a break. |
Humidity is part of the class for a reason. The water in the air is one of the main things that drives a cabinet's performance and energy use, and it rises with each class: 40% humidity at 40°C holds more water than 60% at 25°C, so class 5 is the wettest room of the three, not the driest. Damp air is also a common cause of condensation around cabinet doors.
Climate class and temperature class are two different numbers
The temperature class says how cold the cabinet kept its test packs, called M-packages, during the test. Makers print the two together, climate class first: 3M1 means the cabinet met class M1 in a class 3 room, and 4M1 means it met M1 in a class 4 room.
| Class | What the test packs did | What it tells a food business |
|---|---|---|
| M1 | Warmest pack 5°C or colder, coldest pack -1°C or warmer. | The chilled food class. Storage cabinets for chilled food are tested to it. |
| M0 and M | Warmest pack 4°C or colder (M0) or 6°C or colder (M), coldest -1°C or warmer. | Display classes. M0 runs colder than M1, and M allows a warmer pack. |
| M2 | Warmest pack 7°C or colder, coldest -1°C or warmer. | The class drinks cabinets are tested to. It is not a chilled food class. |
| H1 and H2 | Warmest pack 10°C or colder. | Warmer display classes, not built to hold food at 5°C. |
| L1 | Warmest pack -15°C or colder, and every pack at -18°C or colder at some point in the test. | The frozen food class. Storage freezers are tested to it. |
| L2 and L3 | Warmest pack -12°C or colder. | Warmer freezer display classes. |
Under Standard 3.2.2 (opens in a new tab), potentially hazardous food is kept at 5°C or below, or at 60°C or above, unless the business can show another temperature is safe. For chilled food that means 5°C, so look for M1 or M0: a cabinet tested to M2 or H1 was only shown to keep its warmest pack at 7°C or 10°C. Keeping food cold on your site stays your business's job, and a probe in the food is the check: the guide to food temperature and fridge readings explains why the display and the food can differ.
Display, drinks and storage cabinets are rated differently
| Cabinet | How it is tested | What that means when you buy |
|---|---|---|
| Display cabinet: open or glass door, for customers to see and reach the stock | At class 3, to the temperature class the supplier registers it for. | A maker's sheet may also show a higher class it tested to, or a maximum room temperature. For a warm shop, those tell you more than the class 3 test. |
| Drinks cabinet: a self-contained display fridge for drinks | At class 3, to M2. | Built for non-perishable drinks only. It is not a food fridge. |
| Storage cabinet: the uprights and underbench fridges and freezers in a kitchen | Light duty at class 3, normal duty at class 4 and heavy duty at class 5, each to M1 or L1. | The duty is the most useful line on the sheet for a hot kitchen. Normal and heavy duty cabinets have their energy measured at class 4, light duty at class 3. |
Some cabinets sit outside these rules, so they carry no class under them: roll-in, built-in and pass-through cabinets, remote storage cabinets, combined fridge and freezer cabinets, cabinets with a water-cooled condenser, open-top tables and saladettes for preparing food, and storage cabinets for fresh meat, fish or wine that run at other temperatures. For those, ask the maker what the cabinet was tested to and in what room.
Because the energy figure is measured in different rooms for different cabinets, compare energy figures only between cabinets of the same kind, size and class. The guide to comparing commercial refrigeration energy ratings and running costs shows how.
The maximum room temperature is a separate figure
Many makers also state a maximum room temperature, often called the maximum ambient, in the manual or on the sheet. It differs from model to model: current Australian manuals and sheets give anything from 30°C to 43°C, and one sets its top limit for no more than 4 hours in any 24. A cabinet run in a room hotter than its approved limit, or squeezed into a space without the airflow it needs, can fall outside its warranty. Ask for the limit in writing before you buy.
Classes 3, 4 and 5 mean the same rooms in the international standards as in the Australian rules. The 2012 amendment to the display cabinet standard numbers its test rooms from class 0 to class 8, so a manual may quote a class outside the Australian three, such as class 7, a tropical room at 35°C and 75% humidity. Ask which standard a number comes from. Household fridges use a different system: SN, N, ST and T give the range of room temperatures the appliance is meant to work in, with T the widest at 16°C to 43°C. A household letter and a commercial number are not on the same scale.
How hot does your room really get?
A cabinet works in the air around it, not the average of the building. Measure the room where the cabinet will stand, at the conditions it will meet on its worst day.
- Measure at the spot, at the height the cabinet draws its air. That is near the floor for most underbench and bottom-mounted cabinets, and near the top for a top-mounted one.
- Measure in the heat of service. Take readings on hot days with the ovens, fryers, dishwasher and coffee machine running. A thermometer that logs temperature and humidity, left in place through a hot week, shows the peaks a single reading misses.
- Note the heat sources. Sun through a window, a grill or oven nearby, a heater, or a warm draught from a door all add to what the cabinet has to fight.
- Check the space around it. A refrigerated cabinet gives off its heat into the room. In a small room without ventilation, or boxed into joinery without the gaps the manual asks for, it heats its own air, works harder and can overheat. Several self-contained cabinets in one small room add their heat together.
- Plan for the future layout. In a new fitout, measure a room like it or allow for the equipment that will stand nearby.
Then match the class with a margin. If the room peaks above 30°C, a normal duty storage cabinet was not tested for it, so look at heavy duty. European rules make a light duty cabinet's paperwork say it suits rooms up to 25°C and not hot professional kitchens, which is a fair way to read light duty here too. If a display cabinet will stand somewhere warmer than 25°C, ask the maker how it performs there and what its maximum room temperature is. Where too many self-contained cabinets would heat a small room, the guide to remote or self-contained display refrigeration covers moving the heat outside.
What a class rating does not promise
A class rating shows what the cabinet did in a controlled test, loaded with test packs the way the standard sets out. It is not a promise that it will hold temperature under every room condition or every way of loading it. On a real site these change the result:
- Warm or hot food. Storage cabinets are built to keep food that is already cold, not to chill it down. Cool cooked food first: see the guide to cooling cooked food and the equipment for it.
- Overloading and blocked vents. Stock packed against the air ducts or over the load line stops cold air reaching it.
- Doors. Doors left open, propped open or opened constantly, and worn door seals, let warm, moist air in.
- A dirty condenser. A blocked condenser makes the cabinet work harder, and some makers make regular cleaning a condition of the warranty.
What to ask the supplier for
Ask the supplier to name the standard the cabinet was tested to (ISO 23953-2 for display cabinets, ISO 22041 for storage cabinets), its climate class and temperature class, and its duty if it is a storage cabinet. Then ask for these, and check that they agree with each other.
| Document | What to find on it |
|---|---|
| Specification sheet | The climate and temperature class, such as 4M1, the duty for a storage cabinet, the energy use in kWh per 24 hours, the net volume, the gaps it needs around it, and the heat it gives off. |
| Registration number | A model has to be registered before it can be supplied. Look the number up in the Energy Rating Registration Database (opens in a new tab), or in the same records in the government's open data (opens in a new tab): each entry shows the temperature class, the climate class of each test, the duty class of a storage cabinet, the energy figure and the energy efficiency index. |
| Installation manual | The maximum room temperature, the ventilation gaps, and where the cabinet must not go, such as in sun or beside a heat source. |
| Warranty terms | Any exclusion for a room that is too hot or too humid, for blocked airflow, or for a condenser that has not been cleaned. |
| Rating plate | The model and serial number, the power supply, and the refrigerant type and charge. Check that they match the sheet. |
A used cabinet is outside the supply rules, so it may carry no current registration and its class may be on an old plate only. The guide to comparing commercial refrigeration quotations covers buying used equipment and the warranty questions to ask.
Climate class worksheet
Who to call
We supply, install and service commercial refrigeration for businesses in Bairnsdale and East Gippsland. Our commercial refrigeration equipment supply page explains how to ask for a quote, and our commercial refrigeration page covers the rest of our work. Send the worksheet with your enquiry. To choose the cabinet's format first, see the guide to upright or underbench commercial fridges.
Sources (27)
- Federal Register of Legislation: GEMS (Refrigerated Cabinets) Determination 2024 (opens in a new tab) Checked on 19 November 2026.
- Federal Register of Legislation: explanatory statement to the GEMS (Refrigerated Cabinets) Determination 2024 (opens in a new tab) Checked on 19 November 2026.
- Federal Register of Legislation: Greenhouse and Energy Minimum Standards Act 2012 (opens in a new tab) Checked on 19 November 2026.
- ISO: ISO 23953-2:2005 Amendment 1:2012, refrigerated display cabinets, preview (opens in a new tab) Checked on 20 November 2026.
- ISO: ISO 22041:2019, refrigerated storage cabinets and counters for professional use, preview (opens in a new tab) Checked on 20 November 2026.
- Energy Rating: refrigerated cabinets, industry information (opens in a new tab) Checked on 20 November 2026.
- Energy Rating: Energy Rating Registration Database (opens in a new tab) Checked on 20 November 2026.
- data.gov.au: Energy Rating data for non-labelled products, including commercial refrigerators (opens in a new tab) Checked on 20 November 2026.
- data.gov.au: Energy Rating data dictionary for refrigerated display cabinets (opens in a new tab) Checked on 20 November 2026.
- legislation.gov.uk: Commission Delegated Regulation (EU) 2015/1094, energy labelling of professional refrigerated storage cabinets (opens in a new tab) Checked on 20 November 2026.
- EUR-Lex: Commission Regulation (EU) 2019/2019, ecodesign requirements for refrigerating appliances (opens in a new tab) Checked on 20 November 2026.
- Haier Australia: HRF523XHG refrigerator freezer user guide (opens in a new tab) Checked on 20 November 2026.
- Food Standards Australia New Zealand: keeping food at the right temperature (opens in a new tab) Checked on 19 November 2026.
- Australian Government, energy.gov.au: refrigeration guide for businesses (opens in a new tab) Checked on 20 November 2026.
- SKOPE: GEMS overview (opens in a new tab) Checked on 19 November 2026.
- SKOPE: SC430N upright glass door fridge user manual (opens in a new tab) Checked on 19 November 2026.
- SKOPE: BME600N-A upright fridge specification sheet (opens in a new tab) Checked on 19 November 2026.
- SKOPE: how your refrigeration choice can help with energy costs (opens in a new tab) Checked on 19 November 2026.
- SKOPE: warranty terms and conditions (opens in a new tab) Checked on 19 November 2026.
- Bromic Refrigeration: upright fridge and freezer instruction manual, 2026 (opens in a new tab) Checked on 19 November 2026.
- Bromic Refrigeration: upright display fridge instruction manual, 2023 (opens in a new tab) Checked on 19 November 2026.
- Bromic Refrigeration: cold food display instruction manual, 2023 (opens in a new tab) Checked on 20 November 2026.
- Williams Refrigeration Australia: operating manual for upright and counter products (opens in a new tab) Checked on 19 November 2026.
- Williams Refrigeration Australia: Garnet upright range (opens in a new tab) Checked on 19 November 2026.
- Hoshizaki: RT and FT series undercounter instruction manual (opens in a new tab) Checked on 19 November 2026.
- True Manufacturing: STR, STA and STG installation manual (opens in a new tab) Checked on 19 November 2026.
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page. Checked on 20 November 2026.
Related pages
- Commercial refrigeration equipment supply
How to ask ABL to quote for a cabinet.
- Comparing commercial fridge energy ratings and running costs
Compare tested energy figures like for like.
- Food temperature and fridge air temperature: why the readings differ
Why the display and the food can read differently.
Choosing a cabinet for a hot room?
Send ABL your climate class worksheet with an enquiry, or call and read it out.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.