Commercial fridge temperature monitoring and coolroom alarms
ABL installs temperature monitoring, data logging and alarms for coolrooms and commercial fridges in East Gippsland. How a system works and what to tell us.
Send an enquiry with the monitoring specification on this page, or call ABL. We look at what you store, where the equipment is and who should get an alarm, then set the monitoring up to suit. To start, list the coolrooms, freezer rooms and fridges you want watched.
How to get monitoring set up
Step 1: Fill in the specification
What to watch, what connection the site has, and who gets the alarm.
Go to the recordStep 3: Assessment and installation
We look at the site, fit the sensors, set the alarms and hand the system over.
Go to Installation
What ABL installs
- Digital temperature monitoring for coolrooms, freezer rooms and commercial fridges.
- Data logging, so the temperature record builds itself.
- Alarms that can reach you by SMS or email when a temperature drifts outside its range.
Monitoring can go on equipment you already have, or be part of a new room: see the coolroom and freezer room installation page. Our other work is on the commercial refrigeration page.
What is a temperature monitoring system made of?
| Part | What it does | What to know |
|---|---|---|
| Sensor | Measures the temperature in the room or cabinet. A door contact can also show when a door is left open. | A probe in the air reacts fast when the door opens. A probe held in a buffer follows the food more closely. |
| Logger | Takes a reading at a set interval and stores it. | A reading every 5 to 15 minutes is a common setting. The interval is kept shorter than the alarm delay. |
| Connection | Carries the readings out: the Wi-Fi on site, a network cable, or a gateway on mobile data. | Metal coolroom walls block radio, so the radio part usually sits outside the room with the probe on a lead inside. |
| Alarm | Tells someone when a reading stays outside its limit: a light or buzzer at the unit, an SMS, an email or an app notice. | A light on the wall only helps if someone is there to see it. |
| Record | The stored readings, as a chart or a report. | How long the history is kept depends on the system and its plan. Ask before you rely on it. |
Which kind of system suits your site?
| Kind | How it works | What it suits | Its limit |
|---|---|---|---|
| The alarm on the controller | The refrigeration controller has its own high and low limits. It flashes and switches an alarm output when one is passed. | A site where someone is there whenever it matters. | It tells the people in the building. It keeps no record you can hand over. |
| A standalone data logger | A small logger sits in the room and stores readings in its own memory. Someone downloads them. | A business that needs the record more than the warning. | It warns nobody off site, and the record is only as good as the habit of reading it. |
| Connected loggers on the site Wi-Fi | Loggers send readings through the Wi-Fi to an online store. Alarms go out by email, SMS or an app. | A kitchen, shop or venue with reliable Wi-Fi near the equipment. | It depends on that network. If the Wi-Fi or the power drops, no new readings get out. A system that reports its own lost contact tells you that much. |
| Sensors on a mobile data gateway | Wireless sensors report to a gateway that uses the mobile network. | A shed, a farm coolroom or a site with no wired internet. | It needs mobile coverage and power at the gateway. Some gateways carry a backup battery. |
Wired sensors are reliable, but they can be complex and costly to install. Wireless is quicker to fit and easier to change later. To work out what your own site needs before you call, see the guide to choosing commercial refrigeration temperature monitoring.
What happens in a power cut?
- Most loggers keep recording to their own memory and send the stored readings when the link comes back. That protects the record. It does not protect the stock, because nobody is being told.
- Some systems raise an alarm when the readings stop arriving. That can be the first sign of a power cut, though it can also mean only that the network has dropped.
- A power failure alarm should not have to wait for the room to warm up. An alarm that rests on a backup battery can run flat before the temperature reaches its alarm point.
- So ask how a system finds out about a power cut and how it tells you. We go through that with you before you choose one.
Where do the sensors go?
A coolroom is not one temperature. It is warmer towards the top and the door and colder in the air coming off the refrigeration, and the gap can be several degrees. So where a sensor sits decides what the alarm means.
- In the warmest part of the room. That is usually near the door. If the warmest spot is cold enough, the rest is. Where stock can be damaged by freezing, the coldest spot needs a sensor too.
- Out of the blast from the open door. A sensor right in the doorway alarms every time someone walks in.
- Out of the cold air off the refrigeration. It reads colder there than the stock is.
- With the radio outside the room. The probe goes inside on a lead, and we make and seal the entry through the panel.
- More than one in a big room. One sensor cannot speak for both ends of a long room.
A sensor on the wall measures the room, not the food. Food Standards Australia New Zealand (FSANZ) says a fixed gauge shows the operating temperature of the unit, and that the food itself should still be measured with a probe thermometer (opens in a new tab). For what the difference means day to day, see the guide to food temperature and fridge readings.
How are the alarm limits and delays set?
| Setting | What it is | How it is usually set |
|---|---|---|
| High and low limits | The temperatures that count as too warm and too cold. | From what you store. For chilled food the food standards give 5°C or colder. A low limit matters where stock can be damaged by freezing. |
| Alarm delay | How long a reading has to stay outside the limit before the alarm goes. | A delay of 10 to 30 minutes is common, so a door opening does not raise a false alarm. Yours is set for your room. |
| Delay after a defrost | A longer delay while the room recovers from a defrost. | Longer than the defrost itself. On a freezer room that can be more than an hour. |
| Who is told | The people who get the alarm, and in what order. | One person straight away, and a second if nobody has responded after a set time. |
Every delay is a trade. A longer delay means fewer false alarms and a later warning when the plant really has failed. We set it for how busy your door is, how long your defrost runs and what the stock can take.
What temperature records does a food business have to keep?
The record rule is in Standard 3.2.2A of the food standards, which FSANZ calls the evidence tool (opens in a new tab). These are its main points, in FSANZ's words.
| Question | What the food standards say |
|---|---|
| Who has to keep records? | The rule applies to category one businesses: in short, a caterer or food service business that makes unpackaged, ready-to-eat, potentially hazardous food. FSANZ adds that a record may not be needed where the business can show an authorised officer in some other way that it has managed the risk. See the overview of the food safety management tools (opens in a new tab). |
| How often? | A record each day the business does a prescribed activity. For the temperature of food in storage, FSANZ suggests daily. |
| For how long? | At least 3 months. |
| Does a logger record count? | Yes. FSANZ lists "data logger information in a graph" as a record. Its guide to the standard (opens in a new tab) says a business whose coolroom is monitored by a calibrated data logger or alarm does not have to write the temperature down daily, but should check that the readings are correct and be able to show the readout to an authorised officer. |
| How accurate does it have to be? | The business must have a thermometer accurate to within 1°C. FSANZ recommends calibrating thermometers (opens in a new tab) at least once every 12 months. |
Your own food safety program may ask for more than the standard does. For a record sheet you can use today, see the guide to commercial refrigeration temperature records.
What does an installation involve?
| Stage | What happens |
|---|---|
| 1. Assessment | We list what has to be watched, look at the connection the site has, and agree who gets the alarms. |
| 2. Sensors | We fix the sensors in the right place in each room or cabinet, with the radio part outside the room where that gives a better signal. |
| 3. Connection | We join the system to your network or fit a gateway, and check the signal from every sensor. |
| 4. Settings | We set the logging interval, the limits, the delays and the people to be told, with you. |
| 5. Test | We check that an alarm reaches the people it should, and show you how the system reports a power cut or a lost connection. |
| 6. Handover | You are shown how to read the record, acknowledge an alarm and change who is told. |
After that, a monitoring system needs little: batteries changed when the system asks for them, and an accuracy check about once a year. Cold shortens battery life, so a sensor in a freezer room needs watching more than one in a kitchen.
Three things to ask about any system before you agree to it: whether there is a subscription and what it covers, how long the history is kept, and who you call when the system itself stops reporting.
What happens when an alarm goes off?
An alarm buys time. What you do with the time is yours to decide before the night it happens.
- Someone on the list acknowledges the alarm, so the others know it is being handled.
- They check the room: is a door open, has the power gone, is the temperature still rising?
- They look after the stock under your food safety procedure, and write down times and temperatures.
- If the equipment has failed, they call for a repair.
For the repair, see the coolroom and commercial fridge repairs page. To decide where stock goes before a failure happens, see the guide to a commercial refrigeration contingency plan.
What drives the cost of monitoring?
- How many points you watch. Each room or cabinet is at least one sensor.
- Wired or wireless. Wired sensors cost more to install.
- The connection. Your own network costs nothing extra to use. A gateway on mobile data carries a data plan.
- The plan. Some systems charge a subscription for SMS alarms, faster logging, a longer history or more users. Others have none.
- Accuracy checks. A yearly check of each sensor by its supplier or a laboratory, where your auditor asks for proof.
- The site. Distance between rooms, metal walls and how far the nearest power point is.
Put the first four in the specification below and we can quote for your site.
Your monitoring specification
Towns ABL covers
ABL is based in Bairnsdale and works across Gippsland, so tell us where each site is. A town with a link has its own page.
- Bairnsdale
- Benambra
- Bruthen
- Buchan
- Cann River
- Churchill
- Eagle Point
- Ensay
- Heyfield
- Lake Tyers
- Lakes Entrance
- Lindenow
- Maffra
- Mallacoota
- Marlo
- Metung
- Moe
- Morwell
- Nowa Nowa
- Omeo
- Orbost
- Paynesville
- Sale
- Stratford
- Swan Reach
- Swifts Creek
- Traralgon
If your town is not here, call and ask. See also service areas.
Sources (22)
Checked on 19 November 2026
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page.
- ABL Refrigeration: service areas (opens in a new tab) ABL's own page.
- Food Standards Australia New Zealand: evidence tool, updated 1 October 2025 (opens in a new tab)
- Food Standards Australia New Zealand: overview of food safety management tools, updated 1 October 2025 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2A (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2, revised April 2026 (opens in a new tab)
- Food Standards Australia New Zealand: thermometers, updated 1 October 2025 (opens in a new tab)
- Food Standards Australia New Zealand: storing food safely, updated 1 October 2025 (opens in a new tab)
- Victorian Department of Health: cold chain management, updated 10 July 2026 (opens in a new tab)
- Australian Food and Grocery Council: Australian Cold Chain Guidelines 2017 (opens in a new tab)
- Danfoss: EKC 202 controller for temperature control, user guide, October 2018 (opens in a new tab)
- Testo: Saveris 2 Wi-Fi data logger system, instruction manual (copy held by a distributor) (opens in a new tab)
- Testo: Saveris 2 brochure (opens in a new tab)
- Monnit: ALTA IoT Gateway 4G user guide (copy held by a distributor) (opens in a new tab)
- Monnit: understanding ALTA sensor data logging, updated 23 May 2024 (opens in a new tab)
- Clever Logger: location settings, logging and alarms, updated 17 November 2025 (opens in a new tab)
- Clever Logger: where to place your loggers for best results, updated 17 November 2025 (opens in a new tab)
- Clever Logger: how far can the loggers be from the gateway, updated 17 November 2025 (opens in a new tab)
- Clever Logger: troubleshooting offline gateways, updated 17 November 2025 (opens in a new tab)
- Clever Logger: are there any ongoing costs, updated 17 November 2025 (opens in a new tab)
- World Health Organization: temperature and humidity monitoring systems for fixed storage areas, supplement 6, May 2015 (opens in a new tab)
- Vero Insurance: loss bulletin, alarm failure, 14 May 2018 (opens in a new tab)
Related pages
- Choosing commercial refrigeration temperature monitoring
Work out what your site needs before you ask for a quote.
- Commercial refrigeration temperature records and template
A record sheet for the checks your staff still do by hand.
- A commercial refrigeration contingency plan
Decide what happens when the alarm goes.
Want a warning before the stock is lost?
Send ABL your monitoring specification with an enquiry, or call and read it out.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.