Skip to the content

Removing and disposing of an old air conditioner

Who recovers the refrigerant, makes the power safe and takes an old air conditioner away, who makes good, where it goes, and what records to keep.

Last updated

An old air conditioner has its refrigerant recovered by a licensed technician before it is taken out, and its power disconnected and made safe by a licensed electrician. Then the units come down, the wall and the old spot are made good, and the old units go for recycling, not into landfill. Plan it as part of the replacement quote, with each of those jobs named and someone responsible for each.

How to use this guide

  1. Step 1: Name who does what

    Refrigerant, power, lifting and anything else coming out.

    Go to Who does what
  2. Step 2: Agree the making good

    Brackets, holes, covers, the base and the cable.

    Go to Making good
  3. Step 3: Fill in the scope

    Then keep it with the records from the job.

    Go to the record

Who does each part of removing an old air conditioner?

Removing an old air conditioner, part by part
PartWhat happensWho does it
The refrigerantRecovered from every part of the system before the pipes are opened. The old unit is then labelled as decommissioned and emptied of refrigerant, with the date and a signature.A technician with a refrigerant handling licence (opens in a new tab). The restricted licence (opens in a new tab) covers decommissioning single-head split systems under 18 kW. It does not cover a larger system or a multi-head one, so ask which licence the technician holds. Look for the tick (opens in a new tab) shows the licence type.
The powerThe unit's circuit is disconnected and made safe. If a new unit of the same power goes in the same place with no change to the cables, it can be reconnected like for like.A licensed electrician. Energy Safe Victoria's restricted licence (opens in a new tab) allows like for like disconnection and reconnection only. A connection that is no longer used should be made safe permanently by someone licensed for the work.
Taking the units downThe indoor unit comes off its bracket and the outdoor unit off its base. The outdoor unit of a wall split is a two-person lift, and a large ducted outdoor unit can weigh over 100 kg.The technician, with a second person or lifting gear. Work with a risk of a fall of more than 2 metres is high risk construction work under WorkSafe Victoria's rules (opens in a new tab), so a unit on a roof or a second storey wall needs safe access equipment.
An old gas heaterDisconnected and the gas made safe, if it comes out with the air conditioner.A licensed gasfitter. Energy Safe Victoria (opens in a new tab) says to use one wherever gas appliances are disconnected.
An evaporative coolerWater, power, the roof unit and the roof opening each have a trade.See the guide to replacing evaporative cooling.

Venting refrigerant to the air is prohibited, and the refrigerant handling code of practice (opens in a new tab) requires all of it to be recovered at decommissioning. So the order matters: refrigerant first, then power, then the units. You can check a technician's licence at Look for the tick (opens in a new tab), and Energy Safe Victoria (opens in a new tab) says to ask to see a tradesperson's licence.

What happens to the refrigerant?

The technician returns the recovered refrigerant to a wholesaler or a collection point. From there it goes into the industry's national reclaim scheme, which cleans refrigerant that can be reused and destroys the rest at a plasma-arc facility in Melbourne. The code of practice requires unwanted refrigerant to go back to a supplier or a collection agent, and a business holding a refrigerant trading authorisation has to accept refrigerant surrendered to it.

It matters most for older units. The R22 in older units is both a greenhouse gas and an ozone depleting substance, Look for the tick (opens in a new tab) notes, so a release harms the environment in two ways.

Where does the old unit go?

An air conditioner is mostly metal: copper, aluminium and steel, with small amounts of precious metals in its electronics. It is also e-waste, which the Victorian Government (opens in a new tab) has banned from household rubbish and landfill since 2019. So it goes for recycling, usually taken away by whoever removes it.

If the old units stay with you, have the refrigerant recovered first: Look for the tick (opens in a new tab) says that has to happen before an air conditioner goes in hard rubbish or to the tip. As at November 2026, East Gippsland Shire (opens in a new tab) lists a fee of $10 for an air conditioner at its landfill and transfer stations. Bairnsdale Landfill takes e-waste and scrap metal, and the smaller transfer stations vary. Whether a given site or recycler takes a whole unit is theirs to say, so check before you load the trailer.

Who makes good afterwards?

Settle each of these in the quote. If the new unit goes in the same place, some of it is reused rather than removed.

What an old unit leaves behind, and what to agree
Left behindWhat to agree
Wall bracket and fixingsRemoved, and the holes filled. Who paints?
The pipe hole through the wallSealed against air, dirt, pests and rain, or reused for the new pipes. An open hole lets all of those in.
Pipes, cable and covers on the outside wallRemoved, and the wall patched where they were fixed.
The outdoor base or bracketKept for the new unit, or taken away and the ground or wall made good.
The cable and isolating switchMade safe by the electrician, or kept only if confirmed to suit the new unit. The guide to the electrical work in a quote covers reusing a circuit.
The drainRemoved, or reused where it suits the new unit.
A window or wall unit openingClosed by a builder, or fitted with a new window panel or wall sheet.
Ceiling openings from a ducted systemClosed and finished, and any ceiling insulation moved for the old system put back.

If the house was built or renovated before 1990, see the guide to installation and asbestos before old sleeves, sheets or panels are cut or removed. For the rest of the day itself, see the guide to getting your home ready for installation day.

What records should you ask for?

The business keeps its own records of the refrigerant it recovers, for the regulator. The invoice line is your record. Those rules are as at November 2026.

Old air conditioner removal scope

Old air conditioner removal scope

Fill in the first part yourself, agree the rest with whoever quotes, then copy it or print it and keep it with the job's papers.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The old system

Type
Refrigerant on the nameplate
A new unit goes in the same place
An old gas heater or evaporative cooler comes out too

Who does each part

Making good

Outdoor base or bracket

Disposal and records

Refrigerant recovery named on the invoice
Certificate of Electrical Safety received

Other questions about removing an old air conditioner

Can I take the old unit down myself to save money?

No. Opening the pipes before the refrigerant is recovered releases it, and that is both prohibited and work only a licensed technician may do. The power is a licensed electrician's work.

What if the old unit is coming out and nothing is going in?

The same steps apply, and the connections that are no longer used should be made safe permanently by licensed trades, not just switched off. Ask for the wall hole to be sealed and the circuit labelled or removed.

Can the old pipes or the old spot be used for the new unit?

Sometimes the spot, the hole and the base can be. Old pipes are another matter: see the guide to reusing refrigerant pipes. If the old unit is going to another room instead, see the guide to moving a split system.

Who to call

We install and replace split and ducted systems in Bairnsdale and East Gippsland. Our split system installation page explains how to ask for a quote. If there is an old system to take out, say so, describe what it is and where it sits, and ask whether the quote covers its removal.

Sources (25)

Replacing an old system?

Tell us what is there now when you ask for a quote, and ask whether the quote covers taking it out.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.