Can existing air conditioning refrigerant pipes be reused?

When old refrigerant pipes can serve a new air conditioner and when they are replaced: what makers check, what stays unknown, and a checklist for the quote.

Last updated

Sometimes, and only after a licensed technician has checked them against the new unit. Several makers' instructions call for new pipes, and others allow reuse only when the pipes are the right size and wall thickness, within the new unit's length limits, clean, undamaged and leak tight, with the flared joints remade. Pipes from an older R22 system are usually replaced. So the useful question is not "can pipes be reused" but "can these pipes be reused with this unit", and the answer comes from both model numbers and a check on site.

How to use this guide

  1. Step 1: Know what decides it

    The new model's instructions, the old refrigerant, and the pipes themselves.

    Go to What decides it
  2. Step 2: Collect the details

    Both model numbers, the refrigerant on the nameplate and the history.

    Go to What to collect
  3. Step 3: Fill in the checklist

    Then hold the assessment and the quote against it.

    Go to the record

What decides whether old refrigerant pipes can be reused?

As a rule, used pipework is replaced with the system, because some older refrigerants leave a residue that makes it incompatible with new units. Where a maker does allow reuse, these are the things it turns on. The installation manual for the new model has the final word, and models differ.

What decides whether old refrigerant pipes can be reused
What decides itWhy it mattersHow it is found out
The new unit's instructionsSome makers forbid reusing pipes on a model. Others allow it with conditions, or sell particular models made to reuse old pipes.Read against the exact model number of the new unit.
The old refrigerantToday's R32 runs at about 1.6 times the pressure of the older R22, and the oil from an R22 system does not suit the new one. R22 pipes and flare nuts are usually replaced for an R32 unit, and the models that allow reuse set conditions.The nameplate on the old outdoor unit.
Pipe sizeEach model specifies its pipe sizes. A different system often uses different sizes.The pipe sizes compared with the new unit's manual.
Wall thicknessPipe thinner than specified will not hold the pressure. Small sizes usually need at least 0.8 mm walls and larger sizes 1 mm or more.Measured on site.
Length and heightThe run has to sit within the new model's limits for length and for the height between the units.The route measured against the manual.
Condition and insulationCorrosion, dents or kinks rule that section out. Loose supports and perished insulation are repaired. Both pipes need intact insulation, protected from the sun outdoors.Inspected along the route.
Leaks and contaminationA system that needed refrigerant added often, or had a compressor burn out, may have leaks or dirt inside the pipes.The history, and a leak tightness test by the technician.
Joints and accessFlared joints are remade for the new refrigerant and kept where they can be reached. Pipe buried in a wall cannot be inspected without opening the wall.Where the joints are, and whether the route can be seen.

Reusing pipes is not the same as converting a system to a different refrigerant. A unit is charged only with the refrigerant on its nameplate. If the length of the run is the question, the guide to standard and non-standard installation gives the usual limits.

What stays unknown until the pipes are tested?

Some of the answer can only come once a licensed technician has access to the pipes and tests them. Before then, a quote that reuses pipes rests on assumptions. The usual unknowns are:

  • Leaks. Only a leak tightness test shows them. A leak has to be repaired before any system is filled with refrigerant.
  • The inside of the pipes. Moisture, debris or old oil cannot be seen from outside. Pipes left open to the air are more likely to hold some.
  • Whether the old unit still runs. That affects how its refrigerant is recovered and what can be learned about the pipes.
  • The hidden part of the route. Pipes inside a wall, a ceiling or a floor, and any joins along them.

The refrigerant handling code of practice (opens in a new tab) requires a leak tightness test after a system is moved or altered, and evacuation before every charge of refrigerant. Both are the technician's work. What you can ask for is the result, written into the commissioning record. The guide to commissioning and handover covers what to receive.

What should you collect before the assessment?

Gather these from the outside of the units and from your records. Leave every cover and connection alone.

  • the brand and model of the old indoor and outdoor units, and the refrigerant printed on the nameplate of the outdoor unit, with a photo
  • roughly when it was installed, and whether it still runs
  • any history of leaks, repairs, refrigerant being added or a compressor being replaced
  • photos from the ground of the pipe route, the insulation and where the pipes enter the wall
  • whether any of the pipes run inside a wall, a ceiling or a floor
  • the brand, model and capacity of the new unit you are being quoted, so its manual can be checked

On a multi-split or a ducted system the same applies, and the answer is just as model specific. Some ducted models are made to keep the pipes of an old R22 system, and others are not. For one failed head on a multi-split, see the guide to replacing one indoor unit on a multi-split system.

What should the quote say about the pipes?

Ask for the pipes as their own line, whichever way the answer goes. A quote that reuses pipes should state:

  • that the pipes are reused, which ones, and that the new unit's instructions allow it
  • what was checked to decide it, and what is still to be confirmed by testing
  • what happens to the price and the date if a test fails and new pipes are needed
  • who is responsible if a reused pipe leaks later
  • whether the new unit's warranty allows reused pipes

A quote with new pipes should still say whether the old ones are removed or left in the wall, and who seals the old holes. The guide to removing an old air conditioner covers the rest of the old system.

All of this is licensed work. In Australia, anyone whose work involves handling a scheduled refrigerant, or a part of the equipment that could release one, needs a refrigerant handling licence (opens in a new tab), and that includes installing and decommissioning. A restricted licence (opens in a new tab) covers installing and decommissioning single-head split systems under 18 kW only. You can check a technician's licence at Look for the tick (opens in a new tab). The code also prohibits using refrigerant to flush pipework clean, so a quote should not offer it.

Refrigerant pipe reuse checklist

Refrigerant pipe reuse checklist

Fill in the first two parts before the assessment, from the outside of the units. The technician's answers go in the last two.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The old system

Refrigerant on the nameplate
It still runs
Leaks, or refrigerant added, in the past
Compressor replaced in the past

The pipes

Pipes inside a wall, ceiling or floor
Insulation where you can see it

The new system

Its instructions allow reused pipes

The assessment

Decision

Other questions about reusing pipes

Is it cheaper to reuse the pipes?

It can save some material and time, but on a short run new pipe is a small part of the job. If the new units go where the old ones were, the route and the hole through the wall are often reused even when the pipe is not. The quote should show both prices where the choice is close.

Can I disconnect the old units myself to save time?

No. The pipes hold refrigerant, and Look for the tick (opens in a new tab) says the refrigerant must be recovered by a licensed technician. The power to the units is a licensed electrician's work.

What about pipes put in for a future system?

Pipes roughed in during a build face the same checks, and the new unit has to suit their size and length. The guide to air conditioning a new house before plastering covers planning them. Moving a working system is in the guide to moving a split system.

Who to call

We install and replace split and ducted systems in Bairnsdale and East Gippsland. Our split system installation page explains how to ask for a quote. Send your checklist and the photos of the nameplate with it. If the old system is still worth repairing, see the guide to repairing or replacing an air conditioner.

Sources (17)

Checked on 20 November 2026

Replacing an air conditioner?

When you ask for a quote, send the model numbers of the old unit and a photo of its nameplate.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.