Old ducts can carry a new ducted air conditioner when they are in good condition, insulated and sealed for cooling, and sized for the new unit's airflow, and someone has checked all of that in the roof space. Age or appearance alone does not settle it. Ducts from an older reverse-cycle system are often worth checking. Ducts from gas heating or an evaporative cooler are usually replaced.

How to use this guide

  1. Step 1: Know where they came from

    Reverse-cycle, gas heating or evaporative ducts start from different places.

    Go to When reuse works
  2. Step 2: Ask for the evidence

    Photos and a written finding from the roof space, run by run.

    Go to Condition evidence
  3. Step 3: Record the decision

    What is kept, repaired or replaced, why, and what each costs.

    Go to the record

When can old ducts be reused?

Two things are true at once. Makers allow old ducts to be reused when they meet the needs of the new unit and the rooms and are still in good condition. And as a rule, old ductwork is replaced with the system, because it is likely to be dirty, leaky, short of insulation and the wrong size. So reuse is a case made with evidence, not the starting assumption. Where the ducts came from tells you how strong that case can be.

Old ducts by the system they served
The old systemWhat usually happensWhy
A ducted reverse-cycle air conditionerOften kept in part, if the runs pass the checks below.They were laid out for refrigerated air, so condition, insulation and the new unit's airflow decide it.
Ducted gas heatingUsually replaced.Gas heating ducts are generally too small for a reverse-cycle system, which moves more air at a smaller temperature difference, and they are often short of insulation for cooling. The Essential Services Commission (opens in a new tab), which regulates the Victorian Energy Upgrades program, recommends replacing the ducts and fittings when a gas ducted system is replaced under the program.
An evaporative coolerUsually replaced.The system has no return air, and its ducts and outlets were made for a different job. See the guide to replacing evaporative cooling.
Not knownTreated as unknown until someone looks.The age, the insulation rating and the condition are all in the roof space.

There is no set life for flexible duct. A whole system usually lasts 15 to 20 years, and the ducts age with it, but a duct is judged on what is found, not on its date. Older flexible duct and its insulation may also fall short of today's fire hazard standards.

What evidence should you ask for?

The checks happen in the roof space, run by run. Ask for photos of what was found and a short written finding, so the decision rests on something you can see.

What to check on old ducts, and the evidence to ask for
CheckWhat counts against reuseAsk for
Outer sleeveTorn, split, perished or untaped sleeve. In a roof space the sleeve keeps the insulation dry, and the building code asks for it to be taped airtight and waterproof.Photos of the worst runs.
Insulation ratingA rating below today's minimum. Flexible duct usually has its R-value printed on the outer sleeve.The rating found, and on which runs.
Runs and supportsDucts that are crushed, kinked, sagging between supports, lying on the ceiling or much longer than they need to be. Flexible duct should be fully extended and held up with minimal sag.A note of each run to replace or re-hang.
JointsDucts loose or off at the unit, a branch or an outlet, and joints that are not sealed.Which joints leak or have come apart.
Damp and mouldWater marks, damp insulation, or mould around outlets. Poorly insulated duct can sweat in cooling.Where it was found.
Outlets and return airOutlets too small for the airflow, which makes draughts and noise, and a return air path that is restricted or open to the roof space.The outlet sizes, and the return grille and its duct.
Zone dampersMotors that stick, fail, or will be hard to reach once the new unit is in.Which dampers would be kept.

Will old ducts suit the new unit?

Sound ducts can still be the wrong ducts. Every ducted unit is built to push its air through a set range of resistance from the ducts, called external static pressure. That range differs widely between models: some slim units manage as little as 30 or 50 pascals, while others are rated past 200. Ducts that are too small or too long for the unit restrict the airflow and waste energy. A unit working outside its range can deliver too little air to a room, and some can leak water.

So the designer compares the old layout with the new unit, not just the condition of the ducts. These are the questions:

  • Does each room's run carry the airflow the new heat load needs, at a quiet speed? Each duct size carries a limited flow, and noise at an outlet means more or larger outlets.
  • Does the layout stay inside the new unit's static pressure range, with the run lengths and bends as they are?
  • With only the smallest zone on, does the unit still get its minimum airflow?
  • Is the return air grille and its duct big enough, and sealed from the roof space? The guide to supply outlets and return grilles covers where it goes.
  • Will the old zone dampers work with the new unit's controller? Some makers need their own zone controller and dampers, and some old damper motors draw too much power or are too worn to keep.
  • Does the new unit fit where the old one sat, with room to service it?

Ducts, outlets, grilles and zone motors are usually not the unit maker's parts, and they can sit outside its warranty. Ask how the new unit's warranty treats ducts and controls that are kept.

What should the quote say about the ducts?

Ask for the ducts as their own lines, with a reason for each. A quote that says "existing ductwork reused" tells you little until you know which runs, what was checked and what happens if one fails later.

Duct lines to look for in a ducted quote
Line in the quoteAsk
Ducts keptWhich runs, what was checked, and the photos.
Ducts repaired or re-hungWhich runs, and what is done to each.
Ducts replacedWhich runs, why, and the insulation rating of the new duct.
Outlets and return air grilleKept, resized or replaced, and who finishes the ceiling.
Old outlets not neededClosed and sealed, so the room does not leak air into the roof.
Zone dampers and controllerKept or replaced, and whether they suit the new unit.
Old ducts and unit taken awayIncluded, and who takes them.

As at November 2026, ABL's published guide for a ducted system is from $7,000 to $15,000 or more installed, depending on the size of the home and its zoning. Reusing sound ducts brings a price down and replacing them adds to it, so ask for the reuse and the replacement priced separately where the choice is close. Your quote is the price.

For new ductwork, the National Construction Code (opens in a new tab) sets the minimum insulation for a system that heats and cools by refrigeration at R1.5 in most climate zones, with allowances where the ducts sit under an insulated roof or an enclosed floor, and asks for joints to be sealed. Victoria adopted the 2025 edition on 1 May 2026. A kept duct below that figure loses more heat into the roof space, so ask what rating the kept runs have.

Ducted air conditioning after roof work: what can change?

Anyone who works in the roof space can disturb a ducted system: insulation installers, solar installers, electricians, data and antenna cablers, roofers and pest controllers. The building code asks that ceiling insulation does not affect the safe or effective operation (opens in a new tab) of a service in the roof, which includes the air conditioner. The usual results of roof work are:

  • a duct crushed under a foot, a board or stored boxes
  • a duct pulled off its outlet, a branch or the unit
  • insulation pushed against the unit, over its access panel or across the return air
  • the drain or the safety tray under the unit knocked out of place
  • zone motor wiring or the controller cable disturbed

You will usually notice it from the rooms. Write down what changed and when, and which trade was in the roof:

What you may notice after roof work
What you noticeWhat to record
Little or no air from one outletWhich room, and whether its zone is on. The guide to one ducted room that stays warmer has a map to fill in.
A new noise, whistle or rattleWhere it seems to come from, and in which mode.
Dust or a roof-space smell from the outletsWhich outlets, and when it started.
A water mark or drip on a ceilingTurn the system off at its controller and call. Note where it is, and whether the system was cooling at the time.
A zone that will not switch, or a code on the controllerThe zone, and the code exactly as shown.

Before a trade goes into the roof, show them where the unit, the ducts and the zone motors are, and ask them to keep their materials off the ducts and clear of the unit. If you notice a burning smell, see the guide to air conditioner burning smells and tripping breakers.

Duct reuse decision record

Duct reuse decision record

Fill in what you know about the old system, then the installer's findings as they come in. Copy it or print it to set two quotes side by side.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The old system

The ducts served

What was found in the roof space

Photos received

Matching the new unit

Ducts and outlets checked against the new airflow
Zone dampers and controller

The decision

Other questions about reusing ducts

Can I keep the ducts and only change the outdoor unit?

Not on its own. The indoor and outdoor units of a ducted system come as a matched pair, so a new system means a new indoor unit in the roof as well. The ducts are the part that can sometimes stay.

Is keeping old ducts always cheaper?

At the start, usually. Over the years, ducts that leak or are short of insulation lose heating and cooling into the roof space, and better-rated duct can pay back. Ask for both prices and the reason for each.

What if the installer cannot see all of the ducts?

Then the quote should say which runs were not seen, and what happens if one of them turns out to need replacing. That is a fair thing to have in writing before you accept.

Who to call

We install ducted reverse-cycle systems in Bairnsdale and East Gippsland, and we look at the roof space before we quote one. Our ducted air conditioning page lists what to send. For what else changes the scope of a job, see the guide to standard and non-standard installation.

Sources (21)

Checked on 20 November 2026

Replacing a ducted system?

Tell us what the old system was and when it went in. We look at the roof space before we quote.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.