Air conditioning an apartment: what to check before approval and a quote
Where an apartment air conditioner can go, what crosses common property, what each floor changes, and the pack to prepare for approval and a quote.
Last updated
In an apartment the building decides more of the job than the room does. Before you ask for a firm quote, work out where an outdoor unit could sit, which parts of the pipe and drain route cross common property, where the power would come from, and how a technician would reach the units to service them later. With that in hand, the owners corporation can consider a clear request and an installer can price a real route. Approval and the quote are separate steps, and neither is settled until it is in writing.
How to use this guide
Step 1: Find the positions
Where each unit could go, and what the route crosses.
Go to Outdoor unit position
What is yours, and what is common property?
Your lot is what the plan of subdivision says it is, and so is the common property. Consumer Affairs Victoria (opens in a new tab) says common property is whatever it is stated to be on the plan of subdivision and may include gardens, passages, walls, stairwells, pathways, driveways, lifts, foyers and fences. An outside wall, a roof or a shared service riser is often common property, so an air conditioner that sits on one, or a pipe that runs through one, usually needs the owners corporation's approval.
Under the model rules in the Owners Corporations Regulations 2018 (opens in a new tab), an owner or occupier must not damage or alter the common property without the written approval of the owners corporation. A second model rule says an owner or occupier of a lot must obtain the written approval of the owners corporation before making any changes to the external appearance of their lot, and that the owners corporation cannot unreasonably withhold approval, but may give approval subject to reasonable conditions. That limit on refusing is in the rule about changes to your own lot. The rule about common property has no such wording. So where the unit, its bracket or its pipes sit on or cross common property, do not count on approval.
An owners corporation can make its own rules. Under the Owners Corporations Act 2006 (opens in a new tab), where its rules do not cover a matter that the model rules cover, the model rule on that matter applies. Consumer Affairs Victoria (opens in a new tab) lists what they can make rules about, including the maintenance of air conditioners, alterations that affect the external appearance of a lot, and prior written approval before altering building exteriors, balconies or other attachments. So ask the owners corporation manager for the current rules before anything else. That is as at November 2026.
Where can the outdoor unit go?
The outdoor unit is usually the hardest part to place. It needs air around it, a solid base or bracket, a drain, and room for a technician to work on it. These are the usual places, and what each one raises:
| Position | What it involves | What to settle first |
|---|---|---|
| On the balcony floor | The shortest route from a living room or bedroom. The unit takes up balcony space and needs clear air in front and behind. | Whether the balcony is part of your lot, where the drain can go, and that the unit does not stand where it could be used to climb over the balustrade. |
| On a bracket on the balcony or an outside wall | Keeps the balcony floor clear. The wall has to carry the unit, and a unit off the balcony is out of reach for servicing without access equipment. | Whether the wall is common property, what it is made of, and how the unit will be reached for each service. |
| On the roof or in a plant area | Can suit an apartment with no balcony, or a building that groups its outdoor units. The pipes run a long way, often through a shared riser. | Owners corporation approval for the roof and the route, the model's pipe length limits, and how a technician gets to the roof. |
| In a ground-floor courtyard | Usually the easiest access and the shortest pipes. The unit sits close to neighbours' windows and to people walking past. | Whether the courtyard is part of your lot, where the unit's noise and air would go, and where water can drain. |
| Through a centralised building system | Some buildings supply heating or cooling from a central plant, and a separate unit may not be wanted or allowed. | Ask the owners corporation manager what the building already has and what it permits. |
Where the water goes matters more in an apartment than in a house. Water from a balcony unit should not be run onto the balcony or over its edge. It has to go to the building's sanitary or stormwater drainage, which may mean a shared stack. A unit inside a bulkhead or above a ceiling often needs a pump, and a safety tray under it is good practice. See the guide to planning the condensate drain, and for mounting, the guide to slab or wall bracket.
What changes from floor to floor?
The floor you are on changes how the units are installed, how they are serviced, and who hears them. These are the usual differences:
| Where the apartment is | Access and servicing | Drain, power and noise |
|---|---|---|
| Ground floor | Most work is done from the ground. Ask how the outdoor unit will be protected from knocks, and whether it blocks a path or a gate. | Water has to drain away from paths and other lots. The unit is close to bedrooms above and beside it, so outdoor noise matters. |
| Upper floor with a balcony | Installation and servicing are done from the balcony, if the unit is placed so a technician can stand safely beside it. | The drain goes to the building's drainage, not the balcony. Ask whether the apartment's switchboard and the supply to it have room for another circuit. |
| Upper floor with no balcony | A unit on an outside wall is work at height for every installation and service, which can mean a lift or scaffold each time. | The pipes and drain run down or across the face of the building, which is usually common property. |
| Top floor | A roof position may be possible, reached through the building's roof access. | The pipe run to the roof is long. Ask who keeps the roof watertight around any new fixing. |
Work at height takes equipment and time. WorkSafe Victoria's advice (opens in a new tab) to air conditioning installers is to use the highest level of fall prevention that is reasonably practicable, such as mobile scaffolds or scissor and boom lifts in place of ladders. Every later service of a high unit needs the same safe access, so plan for it now. A unit that cannot be reached safely may not get warranty service, and the manual for the model sets the space it needs around it.
Which kinds of air conditioner can work in an apartment?
Most apartments end up with one of these. Which one suits yours depends on the positions you have found, not on the floor number alone.
| Format | What it needs | The better choice when |
|---|---|---|
| Wall split, outdoor unit on the balcony | A balcony with room for the unit, a short route through the wall, and a drain to the building's drainage. | You have a balcony beside the room. It is the simplest arrangement for most apartments. |
| Multi-split | One outdoor unit serving an indoor unit in each of several rooms. | You want two or three rooms done and there is space for only one outdoor unit. |
| Split with the outdoor unit on the roof | A roof or plant area, a long route through common property, and approval for both. | There is no balcony, and the building already provides a riser or a plant area for this. |
| Window or through-wall unit | An existing window, or a hole made in an outside wall. Smaller units use a power point; larger ones may need a dedicated circuit. | A split cannot be placed. A new hole in an outside wall is a change to the building and needs the same approval. |
| Portable unit | A power point and a window for its hot air hose. No outdoor unit. | You need relief for a short time and nothing else can go in. The hose outlet often does not seal well, so it is less efficient. |
For choosing between one unit per room and a single system for several rooms, see the guide to choosing a room-control layout. For a bedroom where sleep is the priority, see choosing a quiet air conditioner for a bedroom.
What does the building code say about apartments?
Victoria adopted the National Construction Code 2025 (opens in a new tab) on 1 May 2026, with no transition period. The code calls a building containing two or more sole-occupancy units a Class 2 building, and each unit in it a separate dwelling. Two parts of the code matter most when an air conditioner goes into one:
- Fire separation. Clause C4D15 (opens in a new tab) applies where an air-conditioning or other service penetrates a building element, other than an external wall or roof, that is required to have a fire-resistance level. The penetration then has to be protected by one of the methods the clause sets out, such as a tested system. Walls and floors between apartments, and between an apartment and a corridor or riser, are often fire-rated.
- Sound. Part F7 (opens in a new tab) requires a wall or floor between sole-occupancy units, including the effect of services and their penetrations, to minimise the transmission of sound.
So a pipe through a party wall, a floor or a riser is more than a hole. Ask the installer which walls and floors the route crosses, whether any is fire-rated, and how each penetration will be sealed. The owners corporation may also ask for that in writing. How the code applies to new work in an existing building is a question for a building surveyor.
What does the owners corporation need to see?
A request that answers the obvious questions up front is easier to approve. Put these in it:
- a photo or a marked-up drawing of where each unit would go, inside and out
- the outdoor unit's size, weight and outdoor noise figure, from the maker's brochure or manual
- the route of the pipes, the cable and the drain, and which parts cross common property
- how the outdoor unit is fixed, and what it stands on or hangs from
- how a technician will reach the units to service them
- who will do the work, and the licences they hold
- when the work would be done, and for how long
Noise is a common condition. Under Victoria's residential noise rules (opens in a new tab), as at November 2026, air conditioner noise that a neighbour can hear indoors is unreasonable during prohibited times at night and early in the morning, and the guide to choosing an outdoor AC location gives the times. In an apartment the neighbour's window can be a few metres away, so pick a quiet unit and a position away from bedrooms.
If the work needs a building or planning permit, Consumer Affairs Victoria (opens in a new tab) says a lot owner must notify the owners corporation. Anyone can check a refrigerant handling licence on Look for the tick (opens in a new tab).
What if you rent the apartment?
Then the rental provider's permission comes first, and the owners corporation's approval as well. Consumer Affairs Victoria (opens in a new tab) says a rental provider cannot refuse permission without a good reason for changes needed to make sure the renter is not too hot or cold. It also gives examples of good reasons to refuse, including a change that would require modifications to other premises or common areas.
As at November 2026, Victoria's rental cooling standard (opens in a new tab) asks for an energy efficient fixed cooler in the main living area at a new agreement, or when one becomes periodic, from 1 March 2027, and in all rentals from 1 July 2030, with exemptions that include cooling supplied through a centralised building system and an installation the owners corporation rules do not permit: the guide to rental heating and cooling standards in Victoria explains what an exemption changes.
Apartment feasibility pack
Fill this in, attach your photos, and send it to the owners corporation manager and with your enquiry. It describes what you want and what the building allows. It is not an approval, and the installer still has to see the site. Our split system installation page explains how to ask us for a quote.
Other questions about apartment air conditioning
Can the owners corporation say no?
Yes. For a change to the outside of your own lot, the model rule says it cannot unreasonably withhold approval, and it may attach reasonable conditions. For common property, which an outside wall, a roof or a riser often is, the model rule has no such limit. The building's own registered rules may differ from both. Ask for the reasons in writing if it refuses, and whether a different position would be approved.
Who pays to maintain an outdoor unit on common property?
Owners corporation rules can cover the maintenance of air conditioners, so check the rules first. Then ask for the approval to state who owns the unit, who maintains it, and what happens if it has to be removed.
Do I need an electrician as well?
Usually. A split system normally needs its own circuit from the apartment's switchboard, and that is work for a licensed electrician. The guide to the electrical work in a quote covers what to photograph and ask.
How far can the outdoor unit be from the indoor unit?
Every model has a maximum pipe length and height difference, set by the maker. A roof position on a tall building can exceed it. The guide to choosing an outdoor unit location covers airflow, noise and access.
Sources (18)
- Consumer Affairs Victoria: what is an owners corporation, updated 9 April 2026 (opens in a new tab) Checked on 20 November 2026.
- Consumer Affairs Victoria: what an owners corporation can make rules about (opens in a new tab) Checked on 20 November 2026.
- Consumer Affairs Victoria: model rules for an owners corporation (opens in a new tab) Checked on 20 November 2026.
- Owners Corporations Regulations 2018 (Victoria), schedule 2 model rules, version 002 (opens in a new tab) Checked on 20 November 2026.
- Owners Corporations Act 2006 (Victoria), version as at 9 September 2026 (opens in a new tab) Checked on 20 November 2026.
- Consumer Affairs Victoria: maintaining and renovating individual lots in an owners corporation (opens in a new tab) Checked on 20 November 2026.
- Consumer Affairs Victoria: renters making changes to the property, updated 13 October 2026 (opens in a new tab) Checked on 20 November 2026.
- Consumer Affairs Victoria: new minimum energy efficiency standards for rentals, updated 21 October 2026 (opens in a new tab) Checked on 20 November 2026.
- Australian Building Codes Board: NCC 2025 state and territory adoption (opens in a new tab) Checked on 20 November 2026.
- National Construction Code 2025, Volume One, Part A6: building classification (opens in a new tab) Checked on 20 November 2026.
- National Construction Code 2025, Volume One, Part C4: protection of openings (opens in a new tab) Checked on 20 November 2026.
- National Construction Code 2025, Volume One, Part F7: sound transmission and insulation (opens in a new tab) Checked on 20 November 2026.
- EPA Victoria: residential noise, updated 4 November 2026 (opens in a new tab) Checked on 20 November 2026.
- WorkSafe Victoria: injury hotspots, heating and air conditioning installation (opens in a new tab) Checked on 20 November 2026.
- Australian Refrigeration Council: Look for the tick (opens in a new tab) Checked on 17 November 2026.
- AIRAH: residential air conditioning best practice guide (Victoria), second edition 2026 (opens in a new tab) Checked on 20 November 2026.
- Your Home (Australian Government): heating and cooling, updated 2026 (opens in a new tab) Checked on 20 November 2026.
- ABL Refrigeration: air conditioning services (opens in a new tab) ABL's own page. Checked on 20 November 2026.
Related pages
- Split system installation in Bairnsdale and East Gippsland
What ABL installs, and the quote details to send.
- Planning the condensate drain for a split system
Where the water goes, and when a pump is needed.
- Choosing an outdoor AC location: airflow, noise and access
Clearances, noise and service access for the outdoor unit.
Planning air conditioning for an apartment?
Send your feasibility pack with an enquiry, or call ABL to talk through the positions. We look at the site before we quote.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.