Skip to the content

Air conditioning a cafe or restaurant dining area

Plan air conditioning for a cafe, restaurant or pub dining area, kept apart from the kitchen exhaust and refrigeration, with a brief to fill in.

Last updated

Plan the air conditioning for a dining area around its seats, its sittings and its doors, and keep it separate from the kitchen exhaust and the refrigeration, which are different systems with their own rules. Plan them side by side all the same: an exhaust hood pulls air out of the building, and the replacement comes through the dining room unless something else supplies it.

How to use this guide

  1. Step 1: Describe the room

    Seats, sittings, doors, sun, and what the kitchen runs.

    Go to What makes it hard
  2. Step 2: Sort out who does what

    Comfort, exhaust, refrigeration and the council are separate jobs.

    Go to Who does what
  3. Step 3: Fill in the brief

    Then send it with an enquiry, or have it with you when you call.

    Go to the record

What makes a dining room hard to keep comfortable?

A dining room changes faster than almost any other room a business runs. These are the things that move the load, and what to note about each.

What moves the load in a dining room
What happensWhy it mattersWhat to note
The room fills and emptiesEvery diner adds heat and moisture. A full sitting asks for far more cooling than the quiet hour before it, and the system has to cope with both.The number of seats, the busiest sitting and its times, and the quiet hours between services.
The kitchen and the counter add heatAn open kitchen, a pass, a pizza oven or a coffee machine in the room puts heat straight into the dining area.What cooks or heats in sight of the diners, and how far it is from the tables.
The exhaust hood pulls air through the roomAir the hood takes out has to be replaced. Without enough make-up air the building is under suction, which shows up as doors that slam, draughts, and smells going where they should not.Whether there is a hood, whether it has its own make-up air supply, and whether doors are hard to open while it runs.
The make-up air is outside airAir brought in to replace the exhaust is at the outdoor temperature. On a hot or cold day it is felt by the staff and the diners nearest where it arrives.Where the make-up air comes in, and whether anyone complains near that spot.
Doors open to the street or a courtyardAn open door lets conditioned air out and outside air in. A breeze through a door can also stop a hood from catching the fumes it is there for.Every door, and whether it stands open while you trade. Bifold doors to outdoor seating count.
Sun on the glassA shopfront or a wall of windows facing west or north takes a lot of sun into the room, and the tables beside it feel it first.Which way the windows face, and what shades them.

For new building work, the National Construction Code's entrance rule (opens in a new tab) (clause J5D5) makes an exception for a cafe or restaurant with an unconditioned zone at least 3 metres deep inside its main entrance and self-closing doors at its other entrances, and the building code's guide notes that an airlock or a self-closing door can be unsafe where staff carry trays. Your building surveyor says how it applies to a fitout. For the choices at the door, see the guides to shopfront air conditioning with open doors and air curtains at a busy entrance.

Who looks after what

A food business has several systems that move air or remove heat, and each has its own designer, its own rules and often its own contractor. Sorting them out first stops one system being blamed for another's problem.

Comfort, exhaust and refrigeration in a dining venue
SystemWhat it doesWho designs and looks after it
Air conditioning for the dining areaKeeps the people in the room comfortable: temperature, air movement and some control of humidity.An air conditioning contractor. Work on the refrigerant needs a licensed technician.
Kitchen exhaust hood and make-up airTakes fumes, smoke, steam and heat out at the cooking line, and brings in air to replace it. The National Construction Code (opens in a new tab) requires a hood complying with AS 1668.1 and AS 1668.2 where any cooking appliance exceeds 8 kW electrical or 29 MJ an hour of gas input, or where the total input exceeds 0.5 kW or 1.8 MJ an hour for each square metre of the room (clause F6D12).A mechanical ventilation designer and installer. Some councils ask to see the plans, and expect flues placed so smoke and odours do not reach neighbours.
Ventilation of the food premisesStandard 3.2.3 (opens in a new tab) of the Food Standards Code requires food premises to have enough natural or mechanical ventilation to effectively remove fumes, smoke, steam and vapours.The food business, which answers to the council. In Victoria, councils register cafes and restaurants, and Safe Food Victoria licenses dairy, meat and seafood businesses.
RefrigerationCoolrooms, bar and display fridges, ice machines and any cellar cooling. Each has its own refrigeration system and its own heat to reject.A refrigeration technician. See hospitality refrigeration.

In Victoria, installing a mechanical heating, cooling or ventilation system in a building is mechanical services work (opens in a new tab) under the Plumbing Regulations 2018, and work in a plumbing class needs a plumber licensed or registered in that class. Ask each contractor which parts of the job they hold the licence for.

Zones, outlets and controls

Many comfort complaints in a dining room come from where the air lands and who can change the setting, as much as from the size of the unit. These are the questions to settle before the units are chosen.

  • Which areas need their own control? A bar, a dining room, a function room and a sunroom each fill at different times. One controller for all of them means one of them is always wrong.
  • Where will the air land? Cold air dropping onto a table, or blowing across plates, is a common complaint. Outlets go where the air can mix before it reaches people.
  • Who can change the setting? Pick one or two people, lock the rest out where the controller allows it, and set a schedule that has the room comfortable when the first diners arrive.
  • Can a technician get to it? A unit above the tables is serviced when the room is closed. Note where the access is and when the venue is shut.
  • How often will the filters clog? Air near a kitchen carries grease, so units in or beside it need cleaning more often than the same unit in an office.

The guide to a maintenance and reopening calendar covers how often to have a busy site serviced.

When a shop becomes a cafe

The air conditioning a shop already has was chosen for a shop: people passing through, some lighting and stock. A cafe seats people for longer, adds a kitchen or at least a coffee machine, and may add an exhaust hood that pulls air out of the room. Check the existing system against the new use before you plan around it.

  1. Talk to the council first. In Victoria, a cafe must register with its council (opens in a new tab) under the Food Act 1984. East Gippsland Shire Council's first step for a new food business is to contact its building and planning departments to find out which permits are needed.
  2. Check the permits. The council lists changing the type of business activity (opens in a new tab) as a reason a planning permit may be needed, and internal renovations or a change in how many people the building can hold as reasons to see a private building surveyor.
  3. Ask the landlord. Find out whether the existing air conditioning belongs to the landlord, and get consent in writing before anything is changed.
  4. Get the existing system looked at. Note its brand, model and age from the nameplate, and find the last service record. Have a technician look at whether it can carry the new load, and where the kitchen sits in relation to it.
  5. Plan the kitchen and the dining room together. Where the hood goes, where its make-up air comes from, and where the dining outlets go are one conversation.

For a full fitout, the guide to coordinating air conditioning in a commercial refurbishment covers working with the builder and the other trades.

Restaurants, pubs and bistros

What a restaurant, a pub and a bistro add to the brief
VenueWhat is particularWhat to tell us
A restaurant dining roomComfort has to hold across sittings, from the first booking to a full room and back. Diners sit still for an hour or more, so they notice a draught or a warm corner more than shoppers do.The sittings and their sizes, private dining rooms, and the tables that draw complaints now.
A pub or bistroOne building holds several rooms with different hours and crowds: a front bar, a bistro, a function room, perhaps a beer garden through open doors.Each room, when it is busy, and which doors stand open. Which rooms are closed on quiet nights.
A pub cellarThe cellar is a cooling job for the beer, and its gas cylinders are a safety matter. WorkSafe Victoria says hotel staff have died in Victorian cellars after breathing in leaking carbon dioxide or nitrogen, and it calls for gas monitoring and alarms (opens in a new tab) where cylinders cannot be kept in an open or ventilated area.Keep the cellar out of the dining room brief. Its cooling is refrigeration, and its gas safety is a separate system.

Tasting rooms and taprooms beside production

A winery tasting room or a brewery taproom often shares a building, or a wall, with the place the product is made and stored. The visitors' comfort is an air conditioning job. The production side is not: tank and cellar temperatures are held by process refrigeration, and the gases of fermentation need their own ventilation.

  • Carbon dioxide. Wine tanks are often filled with carbon dioxide to keep oxygen out, and in high concentrations it causes asphyxiation (opens in a new tab). In smaller breweries, carbon dioxide from the fermentation tanks is often vented straight into the building (opens in a new tab). It is heavier than air and can collect in low, enclosed spaces.
  • Keep the air apart. Air conditioning recirculates the air of the room it serves. It is not a way to clear production gases, and a taproom unit should not draw its air from the production floor.
  • Separate doors and controls. A door between the tasting area and the cellar or brewhouse that stands open mixes the two, and the visitors' side carries the load of the production side.
  • Production cooling is refrigeration. Tank cooling, glycol chillers and barrel rooms are a separate design. See refrigeration services.

Gas monitoring and the ventilation of the production side are a workplace safety matter for the business. WorkSafe Victoria's guidance on beverage gas in cellars and coolrooms (opens in a new tab) covers cylinders, alarms and access, and a ventilation designer covers the brewhouse or the winery. For the comfort system, tell us where the tanks are, where they vent, and which doors connect the visitor area to production, so it is planned for the visitor side only.

Dining area brief

Dining area air conditioning brief

Fill in what you know, and leave the rest blank. Send it with an enquiry, or have it with you when you call.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The venue

Kind of venue

The room

The kitchen or a cooking counter is open to the dining area
Kitchen exhaust hood

What is there now

The landlord owns the air conditioning

Problems now

What happens next

We assess the site before we quote. As at November 2026, ABL offers a free quote. Our commercial air conditioning page covers the systems we install and look after for businesses. Send the brief with an enquiry, or have it with you when you call.

Sources (16)

Planning a dining room?

Send ABL your dining area brief with an enquiry, or call and talk it through.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.