Commercial air conditioning guides
Planning, maintaining and replacing air conditioning in shops, offices and venues.
Faults and what to record
Air conditioning noise in a mixed-use building: the rules and what to record
Which noise rules cover a business's air conditioning when homes share the building, where the noise travels, and a record for the acoustic consultant.
Updated
Repeated condensate alarm on commercial air conditioning: what to record
What a drain or pump alarm means, why clearing it again does not fix it, what to record each time, and who looks after the pump and the drain.
Updated
Water leaking through the ceiling near commercial air conditioning
What to do about water near commercial air conditioning: keep clear of anything electrical, record when it shows, and get the right trades to assess it.
Updated
Buying and replacing
Air conditioning checks before a commercial fitout or change of use
What new walls, lower ceilings and a change of use do to air conditioning, who checks what, the approvals to ask about, and a change register to fill in.
Updated
Budgeting for a commercial air conditioning replacement
The lines a replacement budget needs beyond the equipment: electrical work, access, building work, removal, commissioning, maintenance and a contingency, with a worksheet.
Updated
Central air conditioning or local systems: which suits a commercial building?
How to weigh central plant against local systems: map the zones and their hours, compare space, power, upkeep and failure, and record the constraints for the designer.
Updated
Commercial air conditioning site survey: what to have ready
What to hand a contractor before a commercial site survey: how each room is used, the equipment records, what you can see of the constraints, and who approves the work.
Updated
Commercial HVAC commissioning and handover: what an owner should receive
What an owner should hold when a commercial system is handed over: test records, drawings, manuals, trained staff and a defects list, with a checklist to fill in.
Updated
Comparing commercial air conditioning quotes line by line
How to line up commercial air conditioning offers: the same design basis, the lines where offers differ, exclusions with a figure, and written questions to every contractor.
Updated
Repair or replace a commercial air conditioning system: how to decide
How to weigh a diagnosed repair against a planned replacement: fault history, parts and refrigerant, the cost of downtime, and a decision record to keep.
Updated
Replacing commercial air conditioning while the business stays open
How to stage a commercial replacement around trading: map the areas, agree shutdown windows, set the order of the stages, and accept each stage before it reopens.
Updated
Writing a commercial air conditioning project brief
How to write one brief for every contractor: the problem and outcome, spaces and hours, priorities and budget, who designs what, the scope and the outputs to ask for.
Updated
Equipment and design
Air curtains and air conditioning at a busy shop entrance
What an air curtain can and cannot do at an open door, what weakens it, how it meets the air conditioning, and a sheet to record the entrance.
Updated
Commercial air conditioning and outdoor air ventilation: two separate jobs
Why a split system recirculates a room's air, how outdoor air gets in, who designs and maintains each part, and an airflow brief for the designer.
Updated
Laying out commercial air conditioning outdoor units on a roof
How to place outdoor units on a commercial roof so they get clean air, can be serviced and replaced safely, and suit the structure and the neighbours.
Updated
Mini-VRF or separate split systems: which suits your building?
Whether one mini-VRF or a split system in each room suits your building, starting from how the rooms are used, with a room schedule to send with an enquiry.
Updated
Rooftop packaged unit or split ducted system: which suits your building?
How a rooftop packaged unit and a split ducted system differ on structure, routes, access, noise, outdoor air and replacement, with a sheet to compare two quotes.
Updated
VRF heat pump or heat recovery: does your building need heating and cooling at once?
Whether rooms on one VRF system need heating and cooling at the same time, why mode conflicts happen, and what to ask about two-pipe and three-pipe designs.
Updated
Maintenance
Commercial air conditioning maintenance agreements: questions to ask before you sign
What to compare between maintenance proposals: the units covered, the tasks and visits, exclusions, reporting, access and who does the work, with a comparison sheet.
Updated
Planning HVAC maintenance for an annual shutdown or closed period
How to use a closed period for air conditioning maintenance: which jobs to save for it, the order of work, what happens if a fault is found, and what to hold before reopening.
Updated
Pre-summer maintenance for business air conditioning: a calendar for the year
When to book the pre-summer service and the heating check around Bairnsdale, what sets the interval for each unit, and the events that call for an extra visit.
Updated
Setting up a commercial air conditioning asset register
One label per unit across drawings, controls, invoices and reports, what to record for each, the records the law and warranties ask for, and a register entry to fill in.
Updated
By type of business
Air conditioning a cafe or restaurant dining area
Planning comfort for a cafe, restaurant, pub, tasting room or taproom, kept apart from kitchen exhaust, refrigeration and production, with a brief to fill in.
Updated
Air conditioning an open plan office and the rooms around it
Planning air conditioning for open floors, meeting rooms, call centres, lunchrooms and offices beside warehouses or depots, with an assessment brief.
Updated
Shopfront air conditioning when the doors stay open
Planning air conditioning for shops, showrooms and reception areas from the door inward, and keeping specialist rooms out of the comfort brief.
Updated
Cannot find what you need? Call ABL on (03) 5153 2650 or send an enquiry.
