Shopfront air conditioning when the doors stay open
How an open door drives the cooling in a shop, showroom or reception area, what sits outside a comfort brief, and an assessment sheet to fill in.
Last updated
Where a shop or reception door stays open, the entrance sets the air conditioning load: conditioned air goes out, outside air comes in, and the people nearest the door feel it first. Plan from the door inward. Map the entrances, the queues, the displays and where staff stand, decide what happens at the door, and keep product refrigeration, medicine storage, clinical rooms, pool halls and process ventilation out of the comfort brief.
How to use this guide
Step 1: Map from the door in
Entrances, queues, displays and where staff stand all day.
Go to Map the spaceStep 2: Draw the boundary
Take out the rooms and equipment with their own rules.
Go to Outside the briefStep 3: Fill in the sheet
Then send it with an enquiry, or have it with you when you call.
Go to the record
What does an open door do to the air conditioning?
An open doorway is a hole in the room the air conditioning is trying to hold. Wind, and the difference between the air inside and out, push air through it both ways. On a hot day the unit nearest the door runs flat out while the back of the shop is cold, and the person at the counter by the door is the one who complains. Close outside doors while the air conditioning runs, and fit them to close by themselves.
For new building work, the National Construction Code asks for an entrance to have an airlock, a self-closing door, a rapid roller door, a revolving door or the like (opens in a new tab) (clause J5D5). The exceptions include a room of 50 square metres or less, an open front shop with an unconditioned zone at least 3 metres deep inside its main entrance and self-closing doors at its other entrances, and a moveable external wall that opens to make a temporary unconditioned space. A loading dock entrance that leads into a conditioned space needs a rapid roller door or the like. Your building surveyor says how these apply to a fitout.
| Option | What it does | What to weigh |
|---|---|---|
| A door that closes itself | Opens for each customer and shuts behind them, so the doorway is open only while someone passes. | How it looks to passers-by, and access for prams, wheelchairs and deliveries. |
| An airlock or vestibule | Two sets of doors with a space between, so both are seldom open at once. | Floor space at the front of the shop. |
| An air curtain | A fan over the doorway blows a sheet of air across the opening and cuts the exchange of air (opens in a new tab) through it. Set correctly, it stops most of the exchange, not all of it. | Wind and a strong pressure difference across the doorway weaken it, and a wider or taller opening needs a stronger jet. It uses energy itself. |
| An unconditioned zone inside the door | Leaves the first few metres inside the entrance without air conditioning, so the conditioned space starts further in. | Customers and staff in that zone get no cooling. |
| A separate zone near the entrance | Gives the area by the door its own unit and control, so the rest of the shop is not overcooled to make up for it. | A second control to set, and someone to set it. |
If the door can close, close it, and have it close by itself. Where it has to stay open, give the entrance its own zone, and consider an air curtain where the doorway is sheltered from wind. The guide to air curtains at a busy entrance goes further into that option.
Map the space from the door in
Walk the space from the entrance to the back wall and note where people are and what gives off heat. Have it ready for the site assessment, which also takes in the sun, the layout and how the air moves.
- Every entrance: the front door, a side door, a loading door, doors to outdoor seating. How often each opens and whether it stands open while you trade.
- Where customers wait: queues at the counter, waiting chairs, the line at the checkouts. People standing still notice a draught more than people walking through.
- Where staff stay all day: the counter, the till, the reception desk, the dispensary. They are the ones in one spot for eight hours.
- Displays and lighting: display lighting adds heat, and a window display takes the sun.
- Heat sources: ovens behind the counter, coffee machines, open refrigerated cases and the equipment that cools them.
- The shape of the room: ceiling height, glass, and which way the shopfront faces.
Open refrigerated display cases spill cold, dry air into the aisles. That cools the store around them, so the aisles beside them can be cold while the checkouts by the door are warm, and fitting doors to the cases makes the store more comfortable for shoppers. The refrigeration guide on open multideck or glass door displays covers that choice.
What sits outside a comfort brief
Many shops and reception areas sit beside a room or a piece of equipment with its own rules. The public area is a comfort job. The rest has its own designer and its own standard, and it is kept out of the comfort brief, with a note of where it is and which doors connect to it.
| Room or equipment | Why it is separate | Who deals with it |
|---|---|---|
| Product refrigeration in a supermarket, bakery, farm shop or florist | Display cases, coolrooms and freezers hold food and stock at set temperatures, and each rejects its own heat. | A refrigeration technician. See refrigeration services. |
| Medicines in a pharmacy | The Victorian Pharmacy Authority's guidelines (opens in a new tab) say temperatures in a pharmacy should not exceed 25°C, unless the premises are built or placed so that they cannot, that thermostatically controlled air conditioning or other cooling is needed for this, and that it should hold the 25°C guideline while the pharmacy is closed. | The pharmacy, which answers to the Victorian Pharmacy Authority. The brief should say that the system needs to hold 25°C day and night, and which rooms hold medicines. |
| Clinical and treatment rooms in a medical or dental practice | Treatment and procedure rooms have air change and air quality requirements set out in the Australasian Health Facility Guidelines (opens in a new tab), and dental sterilising areas have their own ventilation requirements in the dental infection control guidelines. | A health facility designer. The waiting room is a comfort job. |
| Animal treatment and housing in a vet clinic | Victoria's veterinary board asks for cooling, heating and ventilation appropriate to the facility's use (opens in a new tab). | The vet and their designer. The reception is a comfort job. |
| An indoor pool hall | Chloramines from pool water affect indoor air quality, so adequate ventilation is essential (opens in a new tab), with humidity control. | A pool hall ventilation designer. The reception and its doors to the hall are a comfort job. |
| Vehicle exhaust in a workshop or a showroom where cars are driven in | Vehicle emissions, particularly diesel exhaust (opens in a new tab) and carbon monoxide, are a serious hazard in a workshop. They are controlled by piping the exhaust away and by ventilation at the source. | The workshop's ventilation designer. A customer lounge is a comfort job, behind a door that stays shut. |
| Laundry dryers | Dryers give off heat and moist air that their own exhaust has to take outside. | The installer of the laundry equipment. The customer area is a comfort job. |
| Apartments in serviced accommodation | Each apartment has its own system, controlled by its guest. | Planned apartment by apartment. The lobby and corridors are a comfort job for the building. |
This guide is about air conditioning the building. Air conditioning in vehicles, caravans and motorhomes is a different trade.
Shops and showrooms
| Shop | What is particular | What to note |
|---|---|---|
| Clothing store | Fitting rooms are small, closed and lit, and customers in them notice heat first. Display lighting runs all day. | The fitting rooms, the window displays and the counter. |
| Small supermarket | Open cases chill the aisles, while the checkouts by the door take the outside air. | Where the cases are, which are open, and where the checkouts sit. |
| Pharmacy | Medicines set the temperature day and night: see the table above. The dispensary and the retail floor often need separate control. | The rooms that hold medicines, and the trading hours. |
| Furniture showroom | A large floor with a high ceiling, and a layout that changes as stock moves. Air has to reach the floor where people walk, not stay up near the roof. | The ceiling height, the floor area and how often the layout changes. |
| Vehicle showroom | Tall glass facing the street, and large doors that open to bring vehicles in. | How often the vehicle doors open, and whether cars are driven in under their own power. |
| Bakery shop | Ovens behind the counter put heat into the shop, and bread is often cooling on racks. | Where the ovens are, and whether a wall or door separates them from the shop. |
| Farm shop | Doors often stand open, dust comes in from the yard, and trade peaks with the season. | The busy months, the dust, and any cool display or coolroom. |
Receptions, counters and waiting rooms
Reception areas, public counters and waiting rooms differ less by the business than by a few things that change the design. Find the ones that apply to your site.
| What is different | Where you find it | What to note |
|---|---|---|
| Open long hours or around the clock | A hotel lobby, the common areas of serviced apartments. | The hours, and whether the area can run on its own at night while the rest of the building is off. |
| Seasonal peaks | A caravan park office, a visitor information centre, a farm shop. | The busy months, and how many people are inside at the peak. |
| A second door for deliveries | A post office or parcel counter, a small supermarket. | How often it opens, and who works beside it. |
| Staff fixed at a counter by the door | A business reception, a council service counter, a bank branch. | Where they sit in relation to the door and to the outlets. They are in one spot all day. |
| Secure rooms | A bank branch, and any back office kept locked. | How a technician gets access to units in those rooms, and when. |
| A specialist room next door | A medical, dental or vet waiting room, a workshop's customer lounge, a laundromat, a pool reception. | The doors to the treatment room, workshop, dryers or pool hall, and whether they stay shut. The table of rooms outside a comfort brief, above, says who deals with the room next door. |
The waiting area itself is an ordinary comfort job: people sitting for a while, often near the door. What makes it different is the room next door, so the brief notes which doors connect to it and keeps that room out.
When the entrance changes
| Change | What it does | What to check |
|---|---|---|
| A loading entrance moves | Outside air now comes in somewhere else, perhaps beside staff who used to be away from it, and deliveries cross a conditioned area. | Where the new entrance is, who works near it, what door it has, and the building code rule for loading dock entrances above. |
| Outdoor seating opens off the dining room | Bifold or sliding doors turn part of a wall into an opening, and the room beside them behaves like an entrance while they are open. | Whether the doors stay open while you trade, the zone nearest them, and whether that zone can be set separately. |
For a dining room, the guide to air conditioning a cafe or restaurant dining area covers the kitchen exhaust and the doors together. For an office behind the shop, see the guide to planning air conditioning for offices and shared workspaces.
Shopfront assessment sheet
What happens next
We assess the site before we quote. As at November 2026, ABL offers a free quote. Our commercial air conditioning page covers the systems we install and look after for businesses. Send the sheet with an enquiry, or have it with you when you call.
Sources (15)
Checked on 20 November 2026
- National Construction Code 2025, Volume One, Part J5 Building sealing (opens in a new tab)
- Australian Building Codes Board: guide to J5D5, windows and doors (opens in a new tab)
- City of Yarra: business energy efficiency checklist, March 2025 (opens in a new tab)
- Business Queensland: energy saving tips (opens in a new tab)
- Eurovent: recommendation 16/5, air curtains technical overview, March 2025 (opens in a new tab)
- EnergyCut: air curtains, revolving doors and automated doors (opens in a new tab)
- US Department of Energy: open refrigerated display case retrofit guide, June 2013 (opens in a new tab)
- Victorian Pharmacy Authority: guidelines, effective 5 September 2024 (opens in a new tab)
- Australasian Health Facility Guidelines: Part D, infection prevention and control, version 8, April 2025 (opens in a new tab)
- Australian Dental Association: guidelines for infection prevention and control, 5th edition amended (opens in a new tab)
- Veterinary Practitioners Registration Board of Victoria: guidelines, 9 April 2024 (opens in a new tab)
- Victorian Department of Health: water quality guidelines for public aquatic facilities, December 2020 (opens in a new tab)
- WorkSafe Victoria: controlling the risk of exposure to diesel exhaust (opens in a new tab)
- SafeWork SA: hazardous chemicals in automotive workshops (opens in a new tab)
- ABL Refrigeration: air conditioning services (opens in a new tab) ABL's own page.
Related pages
- Air curtains at a busy entrance
What an air curtain does at a door that stays open, and what it does not.
- Planning air conditioning for cafes, restaurants and dining venues
Dining rooms, kitchen exhaust and doors to outdoor seating.
- Planning air conditioning for offices and shared workspaces
For the offices and staff rooms behind the counter.