Staff can clean the parts of a commercial fridge, coolroom or blast chiller that the manual for the model lets them reach: the food compartment, shelves, drawers, door seals and outside panels, with the power isolated the way the manual says and a damp cloth rather than a hose. Anything behind a panel or grille, the evaporator, the drains inside the unit and the electrical parts are for a technician. Write that split down for each unit as a cleaning plan, so every shift cleans the same way.
How to use this guide
Step 2: Fill in the cleaning plan
Surfaces, isolation, cleaners, where the food goes and when to call.
Go to the record
What can staff clean, and where does it stop?
A commercial fridge or coolroom has two kinds of space. The food compartment and the outside are for your staff to clean. The refrigeration and electrical compartments, behind the panels and grilles, are for a technician. The manual for your model draws the exact line, so read its cleaning section and copy its words into the plan. This is the usual split.
| Part | Who cleans it | What to know |
|---|---|---|
| Inside walls, floor and ceiling of the food compartment | Staff | A damp cloth with warm water or a mild detergent, then dry. Surfaces that food touches may need sanitising as well, as the section on food-contact cleaners sets out. |
| Shelves, drawers, pans and shelf supports | Staff | Lift them out where the manual shows how. On some blown-air prep counters, the manual asks for the air duct in the food well to be lifted out and cleaned every day. |
| Door seals | Staff | Warm soapy water and a soft cloth, dried before the door closes. No knife or sharp tool. A torn or damaged seal needs replacing, so note it in the plan and tell us. |
| Glass doors and glass panels | Staff | Glass cleaner or mild soapy water. No hot water on cold glass, because the sudden change can shatter it. |
| Outside panels, handles and touch points | Staff | A soft cloth and soapy water, wiped with the grain on stainless steel, then dried. Handles and switches are easy to leave out of a cleaning routine. |
| Lights, lighted shelves and the controller | Staff, outside only | A wrung-out cloth, so no water runs into the fitting. Do not hose them or soak them. |
| Power lead and plug | Staff look; a qualified person replaces | Look for cuts, cracks or crushing before the plug goes back in. A damaged lead is replaced by the maker's service agent or a similarly qualified person. |
| Condenser coil and filter | Depends on the manual | Some manuals give staff a monthly brush of the condenser or a wash of its filter. Where the coil or filter sits behind a grille or cover, leave it to the technician. |
| Evaporator coil and its fans | Technician | In the coolroom or behind a panel in the cabinet. We clean the coil and fan blades on a service visit. |
| Drain pan, drain line and drain heater inside the unit | Technician | Usually behind a base panel or a rear cover. On some coolroom evaporators, the drain pan also covers moving parts, so it stays in place. |
| Electrical parts, wiring and anything behind a panel or grille | Technician, or a licensed electrician for the building's wiring | Covers stay on. Taking one off can expose live electrical parts. |
The jobs your staff do between service visits, such as looking at the condensing unit each week, are set out on the commercial refrigeration maintenance page.
How do you isolate a fridge before cleaning it?
Cabinet manuals ask for the power to be off before cleaning. How you do that depends on how the unit is connected, so use the method the manual names and write it in the plan.
| How it is connected | How it is isolated for cleaning |
|---|---|
| Plugged into a power point | Switch off at the power point and unplug it, gripping the plug rather than the lead, with dry hands. |
| Wired in, with no plug | Switch off at its own isolating switch, the one the manual or the label names. A wired-in cabinet should have one installed in its wiring for this. If you cannot find it, ask us. |
| A walk-in coolroom or freezer room | Follow the room's own instructions on what to switch off. Wipe the walls, floor and shelves with a damp mop or cloth, and keep water away from the evaporator, the lights, the controller and the alarm. |
| A display cabinet with fans and lights in the food area | On one maker's display cases, the refrigeration is switched off first, then the power, and the fans stay off while the inside is cleaned. |
- The off button is not isolation. On some units, switching off at the controller or turning the thermostat to 0 leaves parts of the unit live. Use the plug or the isolating switch.
- Label each power point or isolating switch with the unit it feeds, so staff switch off the right one and nothing else is turned off by mistake.
- Isolated and locked out. WorkSafe Victoria's (opens in a new tab) advice for cleaning work is to ensure equipment is isolated and locked out before cleaning. For a plug-in fridge, that means the plug stays out, where the person cleaning can see it, until they have finished.
- Isolating means the plug or the switch the manual names. It does not mean going into a switchboard, a cover or the unit's electrical box.
- A wet power point, plug or switch is left alone. Follow the warning at the top of this page.
Switching back on after cleaning
Switch the unit back on once it is dry inside and out and no water has reached a power point, a plug or the electrics. If anything on the danger list at the top of this page happened while you were cleaning, leave it off and call.
What water and cleaners does the manual rule out?
Two things go wrong when commercial refrigeration is cleaned: water gets where the electrics and seals are, and a cleaner damages the surface. These are the usual rules. Models differ, so check the manual for yours.
| Rule | Why |
|---|---|
| No hose, spray or pressure washer on a cabinet, or in a room that was not built to be washed down | Water reaches the electrics and the seals. One cabinet maker warns of electric shock or fire, and on a display case high-pressure water or steam can break the seals and cause leaks. Whether a room was built for washing down is in the section on whether your coolroom can take the cleaning it needs. |
| No flooding | Use a damp cloth or mop. In a display cabinet, water should not go in faster than its drain can take it away. |
| No water on fans, lights or electrical parts | Wipe around them with a wrung-out cloth. Cleaning the electrical parts themselves is a technician's job. |
| No abrasive cleaners, scourers, steel wool or sharp tools | They scratch stainless steel and coatings. Scratches hold dirt and let corrosion start on stainless steel. |
| No chloride cleaners or hypochlorite bleach on stainless steel | They corrode it. If bleach is spilled on stainless steel, rinse it off with water straight away. |
| No solvents on plastic parts or coated doors | Solvents can crack plastic parts and damage a door's coating. Some manuals allow a solvent for grease on bare stainless steel and others rule solvents out, so this one depends on the model. |
| Dry everything afterwards | Water left on stainless steel dries to marks. Water left standing in a coolroom or freezer room is a slip hazard. |
Wet floors from cleaning are one of the slip hazards WorkSafe Victoria (opens in a new tab) lists, and cleaning floors outside working hours is one of its solutions.
Which cleaners and sanitisers suit food-contact surfaces?
Cleaning and sanitising are two steps. Cleaning removes dirt, grease and food waste. Sanitising destroys microorganisms, and it does not work well on a surface that has not been cleaned first (FSANZ, cleaning and sanitising (opens in a new tab)). Under the food standards, a food business keeps the food-contact surfaces of its equipment, such as storage containers and display units, clean and sanitary whenever food that touches them is likely to be contaminated (Safe Food Australia, chapter 3.2.2 (opens in a new tab)). Most other surfaces need cleaning, not sanitising.
| Check | What to look for |
|---|---|
| Is it made for food-contact surfaces? | A sanitiser for food-contact surfaces is food grade. Floor and toilet cleaners and disinfectants are generally not suitable for food-contact surfaces, and some chemicals leave residues that taint food (Safe Food Australia, appendix 6 (opens in a new tab)). |
| Does the equipment allow it? | Check the cabinet or panel manual too. Bleach is one of the most common food sanitisers, and some cabinet makers rule it out on their stainless steel. A product can suit the food and still damage the cabinet. |
| How is it used? | Follow its label for the dilution, the contact time, whether it is rinsed off and how long a mixed batch keeps. Too weak or too strong does not work. This page gives no strengths, because they belong to the product. |
| Do staff have the safety data sheet? | WorkSafe Victoria (opens in a new tab) says employers must have the current safety data sheet for each hazardous substance in the workplace and make it available to employees. Its advice for cleaning work is to use a less harmful product where you can, such as a non-bleach cleaning product. |
| Where is it kept? | Separately from food. FSANZ says to store food away from chemicals (opens in a new tab) like cleaners. |
Keep cleaners and cloths off the food itself: move or cover open food before you clean near it.
Under the food standards, the staff who clean and sanitise need the skills and knowledge to do it, including how to make up and use a food-grade sanitiser. If yours is a food service business that handles unpackaged, ready-to-eat, potentially hazardous food, Standard 3.2.2A may also ask you to show that your cleaning and sanitising is done. The cleaning plan at the end of this page can sit with those records.
Where does the food go while a cabinet is out for cleaning?
Plan this before anyone switches the cabinet off. Potentially hazardous food is kept at 5°C or below or at 60°C or above, unless the business can show that another temperature is safe, and frozen food stays frozen (Safe Food Australia, chapter 3.2.2 (opens in a new tab)). Meeting that is the food business's job, so the plan names where the food goes and who checks it.
- Name the cold storage it goes to. Another fridge or the coolroom, with enough spare room that it is not overstocked, because chilled air has to circulate around the food.
- Move what can go straight in. Take out only as much as you can carry straight to the other cold storage, keep the time out of refrigeration short, and do not move food back and forth.
- Frozen food goes to a freezer. It has to stay frozen, so clean a freezer when another freezer can hold its stock.
- Measure the food, not the display. Check the food itself with a probe thermometer when it moves and before it goes back.
- Back in once it is cold. Return the food once the cabinet is clean, dry and back at its operating temperature.
If food has warmed while it was out, your food safety procedure decides what happens to it, and the coolroom and commercial fridge repairs page sets out the 2-hour/4-hour guide FSANZ publishes. When a coolroom will be out of use for longer, such as for a deep clean or work on the room, a hire coolroom is one option: see coolroom hire. To plan ahead for any unit being out of action, see the guide to a commercial refrigeration contingency plan.
Can your coolroom take the cleaning it needs?
How a coolroom can be cleaned depends on how it was built. A room built to be washed down has a floor graded to a drain, coving, and joints sealed against water. A room without them is wiped and mopped, and one walk-in maker's instructions are to use a damp mop or cloth and not to flush the inside with water. Before you change how a room is cleaned, check it against these points and the room's own instructions.
| Look at | What you want to see | Why it matters |
|---|---|---|
| Where the floor meets the wall | Coving at the junction, sealed along its edges. | Coving gives a continuous surface that stops dirt and grease building up. The food standards guide says coving should ideally be provided for floors that are cleaned by flushing or hosing (Safe Food Australia, chapter 3.2.3 (opens in a new tab)). |
| Panel joints and the base of the walls | Joints that fit tightly, with sealant that is whole: not cracked, lifting, missing or mouldy. | Water that gets into a joint or the base of a panel wets the insulation, which then stops working well, and speeds up corrosion. That matters most where panels are washed down. |
| The floor | No cracks, laid or graded so water does not pool, and a drain where the floor is hosed. | Pooled water can feed pests and splash onto food. Cracks hold dirt. |
| Walls and ceiling | Smooth, washable panels without damage or holes, with the junctions between them tightly joined. | Rough or damaged surfaces are hard to clean properly. Coolroom ceilings are easy to leave out of a cleaning plan. |
| Shelving and fittings | Shelves with a slight gap from the wall, and fittings either sealed to the wall or far enough from it to reach behind. | Food and dirt lodge where a shelf meets the wall, and behind fittings nobody can reach. |
| Door seals and strip curtains | Seals and strips that are clean, whole and in place. | Plastic door strips are easy to leave out of a cleaning plan, and a damaged seal lets moist air in. |
Use cleaning chemicals the panel maker allows. One coolroom panel steel maker says cleaning chemicals must be compatible with its steel and used at the strength and contact time the chemical supplier gives, and it recommends soft nylon brooms and keeping water pressure under 2,760 kPa (400 psi) when its panels are washed down. Another walk-in maker rules out abrasive and alkaline solutions on its panels. Ask for the limits for your room's panels before you wash it down.
If the coving, the joints or the floor are not up to the cleaning the room needs, tell us before you change how it is cleaned. See coolroom and commercial fridge repairs for a damaged room, or coolroom and freezer room installation for a new one. For moisture in panels and joints, see the guide to coldroom condensation and frost.
How do you clean a coolroom between produce crops?
A changeover is usually when the room is empty, so it is the time for a thorough clean and for the refrigeration to be looked at. If you grow or pack berries, leafy vegetables or melons, the food standards for horticulture ask for premises and equipment to be kept clean, sanitised and in good repair so the produce is not made unacceptable. For leafy vegetables and melons, FSANZ's guide to those standards lists cool rooms that are regularly cleaned and sanitised, with their cooling units serviced, among the things a business could do to keep produce at the right temperature (FSANZ, Safe Horticulture Australia (opens in a new tab), November 2024).
- Take everything out. The last crop, culls, rotting produce, leaves, soil and broken packaging. Rotting produce gives off ethylene, which harms vegetables, and fewer spores left behind means less chance of rot in the next crop.
- Clean the bins, crates and pallets too. A container that touches produce is reused only if it can be cleaned and, where needed, sanitised.
- Clean, then sanitise, what the produce touches. Use a cleaner and a sanitiser that the panel maker allows and that will not leave a residue to taint the next crop.
- Dry the room. Leave no standing water. Wet surfaces and high humidity let rots and moulds spread.
- Book the evaporator and drain for the gap. An empty room is the chance to do it.
Some crops pass odours and off-flavours to other produce: onions, garlic, cabbage, celery, potatoes and lettuce among them. Keep them away from other produce, and take the last of them out before the next crop goes in.
For loading the room at harvest, see the guide to cold storage loading during a harvest peak.
Does a blast chiller's cleaning fit your production routine?
A blast chiller is cleaned like a cabinet, with the power isolated and a damp cloth, but it works in cycles, so the cleaning has to fit between production runs. Clean it when it is empty. Food part way through cooling has a time limit: under the food standards, cooked potentially hazardous food is cooled from 60°C to 21°C within two hours and from 21°C to 5°C within a further four hours, unless the business can show its own cooling process is safe (Safe Food Australia, chapter 3.2.2 (opens in a new tab)). So the food is not left waiting outside the chiller while it is cleaned.
| Feature | What it means for cleaning |
|---|---|
| Rounded inside corners and a seamless chamber | Food debris has fewer places to lodge, and the chamber is easier to wipe clean. |
| Tray slides and racking that lift out | The walls behind the racking can be reached and cleaned. |
| A door seal that comes off for cleaning | The seal can be cleaned all the way round, and replaced when it is damaged. |
| Food probes | Clean and sanitise a probe before and after each use. On one maker's chillers, the probe handle is not to be put in liquid. |
| Where the defrost water goes | Some models defrost at the end of every cycle. Depending on the model, the water goes to a drain, evaporates in the unit, or collects in a container that staff empty. |
| Access to the evaporator | On some models a hinged fan panel gives access to the evaporator for cleaning. What is behind it is for the technician. |
| Sealant between the panels | One maker asks for it to be checked every year, because damaged sealant affects hygiene and performance. If it is cracked or lifting, tell us. |
For choosing a blast chiller, see the guide to blast chilling, blast freezing and storage. For buying one, see commercial refrigeration equipment supply.
What needs a technician?
Stop at the panel. What the table of who cleans what gives to a technician is a job for us, or for a licensed electrician where it is the building's wiring. Ice built up on a coil is ours too: do not chip or scrape it, because that can damage the refrigeration circuit.
In Victoria, fixed electrical installation work requires a licensed electrician, as Energy Safe Victoria (opens in a new tab) sets out. Work that involves handling a scheduled refrigerant, or a part of the equipment that could release one, needs a refrigerant handling licence, as the refrigerant handling code of practice (opens in a new tab) (part 2, 2025 edition) sets out.
If a cabinet's electrics have been soaked, leave it off and call us. Energy Safe Victoria's advice (opens in a new tab) for appliances that have been under floodwater is not to plug them in or switch them on until a licensed electrician has tested them.
The cleaning we do on a planned service, such as the condenser and evaporator coils and the drain, is on the commercial refrigeration maintenance page. For an ice machine, see the guide to ice machine cleaning and sanitising. If you use a cleaning contractor, give them the plan, because the same limits apply to them.
We repair walk-in coolrooms, freezer rooms, display fridges and commercial kitchen refrigeration. If cleaning has turned up a fault, see the coolroom and commercial fridge repairs page, and have the cleaning plan in front of you when you call.
Operator cleaning plan
Sources (41)
Checked on 19 November 2026
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2, revised April 2026 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.3 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, appendix 6, cleaning and sanitising surfaces and utensils (opens in a new tab)
- Food Standards Australia New Zealand: cleaning and sanitising, updated 30 September 2025 (opens in a new tab)
- Food Standards Australia New Zealand: storing food safely, updated 1 October 2025 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Horticulture Australia, November 2024 (opens in a new tab)
- South Gippsland Shire Council: food business fit out guide, 2024 (opens in a new tab)
- Energy Safe Victoria: what to do in a power outage, reviewed 9 April 2024 (opens in a new tab)
- Energy Safe Victoria: energy safety during floods, reviewed 16 March 2026 (opens in a new tab)
- Energy Safe Victoria: Restricted Electrical Worker's licence, reviewed 1 July 2026 (opens in a new tab)
- WorkSafe Victoria: injury hotspots, cleaning, reviewed 7 September 2026 (opens in a new tab)
- WorkSafe Victoria: hazardous substances safety basics, reviewed 30 July 2022 (opens in a new tab)
- WorkSafe Victoria: preventing slips, trips and falls under 2 metres, reviewed 25 August 2026 (opens in a new tab)
- Australia and New Zealand refrigerant handling code of practice, part 2, 2025 edition (opens in a new tab)
- Australian Government: Triple Zero (000) (opens in a new tab)
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page.
- SKOPE: user manual for the SC430N upright glass door fridge, February 2022 (opens in a new tab)
- SKOPE: user manual for the SC112N-A four glass sided chiller, January 2022 (opens in a new tab)
- SKOPE: user guide for TME, SKT, BME and SKB glass door fridges, February 2020 (opens in a new tab)
- SKOPE: ReFlex storage cabinets user guide, October 2021 (opens in a new tab)
- SKOPE: refrigeration and freezer troubleshooting (opens in a new tab)
- Williams Refrigeration Australia: operating manual for upright and counter refrigeration, April 2020 (opens in a new tab)
- Williams Refrigeration: GEM multideck operating manual, December 2022 (opens in a new tab)
- Williams Refrigeration: reach-in blast chiller and blast freezer operating manual (opens in a new tab)
- Williams Refrigeration: blast chillers and blast freezers brochure (opens in a new tab)
- Bromic: underbench fridges instruction manual, June 2022 (opens in a new tab)
- Bromic: semi vertical and full height multideck instruction manual, June 2025 (opens in a new tab)
- Bromic: modular coldroom installation manual, May 2005 (opens in a new tab)
- True Manufacturing: T-series reach-in installation manual, July 2021 (opens in a new tab)
- True Manufacturing: refrigerated food prep installation manual, May 2023 (opens in a new tab)
- TEFCOLD: Express display cabinets instruction manual, 2021 (opens in a new tab)
- Hussmann: Impact MT merchandiser installation and service manual, June 2010 (opens in a new tab)
- Bally Refrigerated Boxes: walk-in coolers and freezers service manual, May 2013 (opens in a new tab)
- Nor-Lake: walk-in installation manual, March 2018 (opens in a new tab)
- Heatcraft: unit coolers installation and operations manual, June 2026 (opens in a new tab)
- Zanussi Professional: Rapido blast chiller-freezer specification sheet (opens in a new tab)
- BlueScope: technical bulletin 31, COLORBOND Intramax steel for coolroom panels, December 2020 (opens in a new tab)
- Postharvest management of vegetables (Hort Innovation): cool rooms (opens in a new tab)
- Postharvest management of vegetables (Hort Innovation): ethylene (opens in a new tab)
- Postharvest management of vegetables (Hort Innovation): factors affecting postharvest disease development (opens in a new tab)
- Ontario Ministry of Agriculture, Food and Agribusiness: troubleshooting cold storage problems, 2024 (opens in a new tab)
Related pages
- Commercial refrigeration maintenance in Gippsland
For the cleaning a technician does on a service visit.
- Commercial refrigeration maintenance checklist
Work out how often each unit is serviced.
- A commercial refrigeration contingency plan
Plan where the food goes when a unit is out of action.
Something behind a panel needs cleaning?
Call ABL or send an enquiry, and tell us the equipment and what your cleaning plan leaves for the technician.
Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.