Skip to the content

Upright or underbench: choosing a commercial fridge format for each station

Compare upright, underbench, drawer, roll-in and display fridges on the pans they hold, reach, ventilation and service access, with a matrix to fill in.

Last updated

An upright commercial fridge holds more stock for the floor it takes, so it suits bulk and reserve stock. An underbench fridge holds less, but it puts stock under the bench where it is used and gives you a work surface on top. Drawers suit pans fetched again and again through a service, a roll-in suits food that already moves on trolleys, and a display suits stock that customers pick for themselves. You can mix formats, choosing station by station from the pans you actually use, how often staff reach in, the air the cabinet needs and how a technician will get to it.

How to use this guide

  1. Step 1: Find the format for each job

    Uprights, underbench doors and drawers, roll-ins and displays, side by side.

    Go to Formats compared
  2. Step 2: Fill in the matrix

    Your pans, reach, fetches, air and service access, with two cabinets compared.

    Go to the record
  3. Step 3: Call

    Read the matrix out when you call, or send it with an enquiry.

    Call (03) 5153 2650

Which format suits which job?

Commercial fridge formats compared on what they hold, reach and the space they need
FormatWhat it holds wellReach and liftingSpace and air
UprightBulk and reserve stock on full-width shelves. Some take GN 2/1 pans, others only GN 1/1 pans or crates.Its shelves run from near the floor to well above the bench.More stock for its floor space than an underbench. Where the refrigeration unit sits on top, it needs clear space above.
Underbench with doorsPans, tubs and bottles that one station uses in a service. The top is a work surface.Every shelf is below the bench, so reaching the back means bending low.Less stock for its floor space. Some breathe through the front and need no gap at the sides or back. Others need a gap all round.
Underbench with drawersGN pans in drawers that pull fully out. On some cabinets the pans are bought separately.The pan comes out to you, so there is no reaching into the back of a low shelf.Room in front for the drawer to pull out and for you to stand at it.
Roll-inWhole trolleys of trays or pans, wheeled in as they are.Staff push a trolley instead of carrying trays one at a time.A level route for the trolley, a ramp or floor at the door, and height for a tall cabinet.
Display, on the counter or the floorPackaged food and drinks that customers choose for themselves.Customers open it, so its doors have to suit them and the aisle.Keep them out of direct sun and away from an open door.

To put numbers on it: on one maker's cabinets, a single-door upright holds about 470 litres gross on about half a square metre of floor, while a two-door underbench holds under 300 litres gross on about 0.9 square metres, with a bench on top. The figures on this page are examples from current specification sheets and manuals. Other makers' figures differ, so the sheet for the model you are considering decides.

In a kitchen layout this usually means reserve stock in an upright or a coolroom, underbench doors or drawers at each station for what that station uses in a service, and display cabinets on the customer side. Whether you need a coolroom at all is covered in the guide to a coolroom or commercial fridges, and the whole kitchen in the guide to planning refrigeration in a commercial kitchen layout.

Will your pans and trays fit?

The litres on a specification sheet are not what you can load. Count capacity in the pans, trays, crates and bottles you actually use, at your busiest.

What reduces the space you can load
What reduces itWhat it means
Gross against net volumeGross volume is the whole inside of the cabinet. Net volume runs from the bottom grid to the load line. On two current uprights, net volume is about a sixth to almost a quarter less than gross.
Air gapsCold air has to move around the stock, so leave the gap at the back and top that the manual for the model asks for.
The cabinet floorStock goes on the shelves, not on the floor of the cabinet.
Shelf loadShelves have a weight limit, for example 20 kg each. Take stock off a shelf that bends.
OverstockingA fridge packed beyond what it can chill does not keep the food at temperature, and the air cannot reach every item.
Pan and tray sizes to check against the shelves
Pan or traySizeWhat to check
GN 1/1530 x 325 mmThe standard full-size pan. A two-door underbench usually takes one per shelf.
GN 2/1650 x 530 mmNeeds a shelf at least that big. A GN 2/1 upright has shelves about 530 by 650 mm. A slimmer upright may take only GN 1/1.
GN 1/2, 1/3, 1/6 and 1/9Fractions of a GN 1/1Two 1/2 pans, three 1/3 pans, six 1/6 pans or nine 1/9 pans fill the space of one GN 1/1.
Pan depthCommonly 20 to 200 mmA drawer limits the depth. Some underbench drawers take GN 1/1 pans up to 100 mm deep, with a lip no more than 5 mm high.
Bakery trays600 x 400 mmLarger than a GN 1/1 pan, so a shelf or trolley made for GN pans may not take them.
Bottles, cartons and cratesMeasure themThe shelf spacing sets the tallest item. On some cabinets the shelf heights adjust.

Write down how many of each you hold at your busiest, then check how many fit in each cabinet you are considering. The matrix at the end of this guide has room for it.

Drawers or doors at a preparation station?

Drawers and doors at a preparation station
PointDrawersDoors
Getting to the stockThe drawer pulls fully out and you lift the pan from above.You reach in to a shelf below the bench, and to the back of it.
What fitsGN pans of the depth the drawer takes.Pans, tubs, bottles and boxes of mixed heights. On some cabinets the shelf heights adjust.
Space in frontThe full length of the drawer, plus room to stand.Room for the door to swing open to 90°.
CleaningOn some cabinets the drawers lift out for cleaning.Shelves and their supports come out. Each door has a seal to keep clean.
Changing laterOn some ranges the same underbench body takes doors or drawers.On those ranges, doors can be swapped for drawer bays.

Choose drawers where the same pans are fetched again and again through a service, and doors where you store mixed or tall items. For a counter with pans in its top as well, see the guide to choosing a refrigerated preparation counter.

Reach, lifting and how often you fetch

WorkSafe Victoria's (opens in a new tab) advice for kitchens is to keep the lifting and handling of heavy and frequently used items between shoulder and mid-thigh height, and to choose equipment that limits awkward postures and bending. It names sliding trays in display cases as one way to improve access.

  • In an upright, put the heaviest and most-fetched lines on the middle shelves, and light, slow-moving stock at the top and bottom.
  • Under the bench, every shelf is low, and a pan fetched forty times a service means forty reaches below the bench.
  • Count the fetches for each line in your busiest hour. The lines fetched most belong at the station that uses them, at an easy height.
  • Every opening lets warm air in. The practice list for refrigerators in the food standards guide (opens in a new tab) includes opening doors no more than necessary, keeping the time food spends out of refrigeration short, and not taking food out and putting it back again and again. Stock at the point of use helps with all three.
Matching the format to how often you fetch
How you fetchWhat usually suits
A few trips a shift, for bulk or reserve stockAn upright, or a coolroom, near the stations it supplies.
The same pans many times an hourDrawers or an underbench cabinet at the station.
Whole trays or batches at onceA roll-in, if the food already moves on trolleys.
Customers helping themselvesA display cabinet on the customer side.

Roll-in cabinets and trolleys

A roll-in cabinet is loaded with a trolley of shelves that goes into the cabinet as it is. It suits food that already moves on trolleys, because nobody unloads it tray by tray. Check these before you choose one.

  • The trolley fits the cabinet. Measure the trolley with its handles and castors, and compare it with the door opening and the inside of the cabinet. Some roll-ins take several trolley sizes, and the trolley can be a separate order.
  • Which way the trays load. GN 1/1 trolleys come with the trays loading either 325 mm wide or 530 mm wide, and on some models the direction is set when the cabinet is ordered, so say which you need.
  • GN pans or bakery trays. Bakery trays are bigger than GN pans, so a trolley and cabinet made for one may not take the other.
  • The floor and the route. Some roll-ins have their own floor with a ramp up to it. Plan a level route a trolley can use, from where it is loaded to the cabinet door.
  • Height. A single-door roll-in can stand 2240 mm tall. Check the ceiling, and any space the manual asks for above the cabinet.
  • It stores, it does not cool. A storage cabinet holds food that is already cold. Food that goes onto a trolley hot needs cooling first: see the guide to cooling cooked food and choosing the equipment.
  • No GEMS energy figure. Roll-in cabinets are outside the GEMS determination for refrigerated cabinets, so there is no GEMS energy figure to compare. Ask the supplier what the cabinet uses.

Front-breathing or rear-vented?

A self-contained fridge cools its condenser with room air and puts the heat it removes back into the room. A front-breathing cabinet takes in and lets out that air through a grille at the front, so it can sit against walls and under a bench. A cabinet that vents at the back, sides or top needs open space there. Without the air it needs, a cabinet works harder, uses more power and can overheat.

Clearances differ: examples from current manuals
CabinetWhat its manual asks for
A front-breathing underbenchNo gap at the top, sides or back. Keep the front grille clear.
An underbench that does not breathe from the front150 mm from the walls and the ceiling.
An upright with its refrigeration unit on top300 mm above it on some cabinets, 500 mm to the ceiling on others, for air and for service access.
A glass-door upright100 mm behind it, and not recessed or enclosed in a cabinet.
A reach-in fridge and freezerThe fridge: 25 mm behind. The freezer: 76 mm above and behind.

These differ widely, so the manual for the model decides. Even a front-breathing cabinet needs its grille kept clear: no boxes, bins or stock in front of it, and nothing stacked on top of an upright.

Check the cabinet is rated for the hottest your room gets: a class 5 or heavy duty cabinet is tested at 40°C. See the guide to commercial fridge climate classes, and the guide to remote or self-contained refrigeration for where the heat goes.

Can a technician get to it?

Every cabinet needs its condenser kept clean and, from time to time, a technician at its refrigeration unit. Plan for both before the cabinet goes in.

  • The condenser and its filter. They often need cleaning monthly, and the filter can sit behind a bottom grille at the front or on top of the cabinet. A grille or a top that nobody can reach gets missed. The refrigeration maintenance page covers routine care and servicing.
  • The refrigeration unit. We need to reach it to service the cabinet, so nothing should block normal service access. Some underbench cabinets have a refrigeration cartridge that comes out in one piece for service. Ask how the model you are considering is serviced, and leave room for it.
  • Getting it out. Castors, and a power cord long enough, let a cabinet be moved for cleaning behind and under it. On some cabinets the castors cannot be adjusted, so the floor has to be level.

Moving a fridge into a fitted counter

Before a fridge goes into new joinery or a fitted counter, check its manual for three things: whether it may be built in at all, the air gaps it needs, and how it comes out for service. Some cabinets are made to stand free only: some manuals rule out recessing them or enclosing them in another cabinet. The joinery has to leave the cabinet's air path open, and the ventilation section has the gaps.

  • The air path. Nothing in the joinery, such as a back panel, a shelf above or a kickboard, closes off the openings the cabinet breathes through. The ventilation openings in the surrounding structure stay clear.
  • Hygiene. Either butt the cabinet against the joinery with the joints sealed, or leave room to clean its sides. Legs or a plinth should raise it high enough to clean underneath. Safe Food Australia's guide to the food premises standard (opens in a new tab) says boxed-in spaces such as bases to bench units generally should not be used unless they are vermin proofed, because pests can nest in them.
  • Doors and drawers. They still open fully once the joinery is built around them.

Check the gaps in the manual against the joinery drawing before the joiner starts, and ask the supplier of the cabinet if anything is unclear.

Door hinges and stock access

Decide which way each door opens before you order, by watching how staff move at that spot during a service.

  • Hinge side. Choose the hinge side so the open door does not block the walkway or the bench you load from. Some cabinets have reversible doors and arrive hinged on one side, so say which side you need when you order.
  • How far it opens. Some doors are not meant to open past 90°, and some hold open at 90° while you load. Leave room for that swing.
  • Closing. Many doors close themselves, which needs the cabinet standing level. Sliding display doors may not close themselves. Doors and drawers closed after use keep the walkway clear and the cold in.
  • Cleaning. Every door has a seal to keep clean and to change when it is damaged, because a damaged seal does not seal properly and uses more power.
  • Glass or solid. See the guide to glass-door or solid-door commercial refrigeration.

Countertop or floor-standing display?

A display fridge has two jobs: holding stock at temperature, and letting customers see and reach it. Whether it sits on the counter or the floor comes down to how much you sell from it and how much bench you can spare.

A display on the counter and a display on the floor
PointOn the counterOn the floor
Where it goesOn a bench strong enough for it fully loaded. A loaded countertop chiller can weigh 120 kg. It takes bench you might use for service.On the floor, taking floor space and part of the aisle, and leaving the bench free.
How much it holdsA small range, restocked often.More lines, and more stock between restocks.

Every restock is a door opening, so restock a small countertop display when trade is quiet. When a display is first switched on, let it reach its operating temperature before you load it, and keep stock below its load line and clear of its air grilles.

A display for a narrow shopfront

  • Sliding doors open along the front of the cabinet, so they take no aisle space. Some sliding doors do not close themselves, so staff need to check them.
  • Depth. Measure the aisle that is left once the cabinet is in, with a customer standing at it. A low display can be 825 mm deep with its bumper rail.
  • Height. A low display keeps sight lines open across a small shop.
  • Sun and the doorway. Keep it out of direct sun through the window, and away from the open doorway. FSANZ's (opens in a new tab) advice for displayed food includes keeping it away from open windows, doors and fans.

For open displays, glass doors and a display near the entrance, see the guide to open multideck or glass-door display refrigeration.

Fridge noise in customer areas

  • Where the noise comes from. A self-contained cabinet has its compressor and condenser inside it, so its noise is in the room where it stands. A remote cabinet runs from a condensing unit elsewhere, which can be outside, taking the noise and the heat with it. A remote system needs piping and installation work, and is harder to move later. The guide to remote or self-contained refrigeration compares the two.
  • Compare the figures. Some specification sheets give a sound level in dB(A). For example, a two-door underbench fridge may be 61 dB(A), and 59 dB(A) in a quieter mode. Compare figures only where they are measured the same way, and ask the supplier how.
  • Placement. Put the cabinet where its vents stay clear. A self-contained cabinet with blocked vents may not work properly.
  • A new noise from a cabinet that used to be quiet is worth reporting: see refrigeration repairs.

Other appliances on the fridge's power

A commercial fridge runs all day and all night, and it is not meant to be switched off in normal use. Plug it straight into an earthed power point with safety switch protection. Do not use a power board, an adapter or an extension lead. Many manuals ask for a circuit of its own, so check the manual for the model.

So if a kettle, a toaster, a heater, a coffee grinder or another fridge is to share its power point or circuit, have a licensed electrician review the circuit and the load first. Energy Safe Victoria (opens in a new tab) is clear that electrical work is not a DIY job, even a small one such as changing a power point, and that fixed electrical installation work (opens in a new tab) needs a licensed electrician.

For the electrician, list what is plugged in where, and the current each appliance draws, from its rating label. For example, an underbench fridge may draw 2.0 A and the freezer of the same size 4.5 A. Mark the fridge's power point so nobody switches it off by mistake. Many current cabinets use a flammable refrigerant, so some manuals ask that no electrical equipment sits under the cabinet.

A busy cafe milk station

Food Standards Australia New Zealand (opens in a new tab) lists milk among the foods normally considered potentially hazardous. Potentially hazardous chilled food is kept at 5°C or below, unless the business can show another temperature is safe, and frozen food stays frozen. At a coffee machine the milk goes in and out all through service, so the fridge there has to hold its temperature through constant opening.

  • At the machine. A small underbench fridge at the coffee machine lets the jug go back in between orders, so milk spends less time out of refrigeration.
  • Reserve elsewhere. Keep the reserve in an upright or the coolroom, and restock the station fridge before the rush and in quiet spells, with milk that is already cold.
  • Size it by bottles. Count the bottles of each milk you use in your busiest hour, and measure the tallest bottle against the shelf spacing.
  • Heat. A coffee machine is a heat source. Keep the fridge away from it where you can, and choose a climate class for the hottest the bar gets: heavy duty storage cabinets are tested at 40°C.
  • Many openings. Whether a glass door helps at a fridge opened all through service is covered in the guide to glass-door or solid-door commercial refrigeration.

One model across several sites?

Using the same models at each site helps staff who move between sites, because the controls, the loading and the cleaning are already familiar. But sites differ, and a model that suits one can be wrong for another.

  • Standardise the pan size first. GN is a standard footprint, so pans from different makers fit the same cabinets. Rims and corners still differ a little, so try one of your own pans in a drawer or a well before you buy. A common pan size keeps preparation and storage consistent even where the cabinets differ.
  • Keep the same format for the same job, such as drawers at every cook line, and choose the model for each site.
  • Check each site for the hottest the room gets and the climate class that suits it, the space and gaps the model needs, the power supply, which way the doors can swing, and whether customers or only staff use it.
  • Compare energy like for like. Display and storage cabinets covered by the GEMS determination have to meet its energy requirements, and each is tested for its daily energy use. The guide to comparing commercial refrigeration energy ratings explains the figures.

Fill in one matrix for each site.

Cabinet format decision matrix

Cabinet format decision matrix

Fill in one matrix for each station or site. Measure the space and your pans, trays and bottles first, then compare two cabinets side by side.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The station

Opened by

What it has to hold

Food arrives on trolleys

Reach and retrieval

Restocked

Air, access and power

Going under a bench or into joinery
Room for a technician to reach the refrigeration unit
Other appliances share its power point or circuit

Cabinet 1

Cabinet 2

Leaning towards

What to bring us

ABL supplies commercial refrigeration equipment. Send the matrix with an enquiry through the equipment supply page, or have it in front of you when you call, with the measurements of the space and a photo of the station. For refrigeration across a cafe, restaurant or bar, see hospitality refrigeration. If a cabinet you already have is not holding its temperature, see refrigeration repairs.

Sources (28)

Checked on 19 November 2026

Choosing cabinets for a kitchen or shop?

Send ABL your format matrix with an enquiry, or call and talk it through.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.