Skip to the content

Glass-door or solid-door commercial fridge: which suits your business

How glass-door and solid-door commercial fridges compare on visibility, door use, heat, sun, condensation, cleaning and energy, with a comparison sheet.

Last updated

Choose a glass door where seeing the stock does a job: where customers pick from the cabinet, or where staff would otherwise open doors to look for stock or check what is left. Choose a solid door where nobody needs to see in, or where the cabinet stands in heat, sun or humid air, which glass handles less well. The door alone does not settle which uses less energy. Compare the tested energy figures of models built for the same duty, taken from each model's specification, and weigh how often the door will open where the cabinet stands.

How to use this guide

  1. Step 1: Note where it will stand

    The room, the heat, the sun and how often the door will open.

    Go to Location and light
  2. Step 2: Fill in the comparison sheet

    The job, the room, the door use and each candidate's figures.

    Go to the record
  3. Step 3: Call

    Read us the sheet, or send it with an enquiry about a cabinet.

    Call (03) 5153 2650

How do glass and solid doors compare?

Glass and solid doors on a commercial fridge, point by pointScroll sideways to see every column.
PointGlass doorSolid door
Seeing the stockStock shows before anyone opens the door. On a display cabinet, customers choose through the glass.Stock is out of sight. Someone opens the door to look.
Heat through the doorGlass is a poorer insulator, so the doors are double or triple glazed.No glass for heat to pass through.
Lights and heatersUsually lit inside so the stock shows. Some have a heater in the glass or the frame to keep it clear.On some models the light comes on only when the door opens.
Humid airThe glass can sweat in warm, humid air, and the inner pane can fog for a moment after an opening.No glass to sweat. Moisture can still show around the door if it does not close fully.
Heat in the roomThe glass-door version of a cabinet can be rated for less heat than the solid-door one.A hot kitchen still needs a cabinet rated for it.
CleaningOn a display cabinet the glass presents the stock, so marks show. Glass broken near open food is a food safety matter.Stainless steel shows finger marks too, and is wiped with the grain where the grain shows.
Energy figureCompares fairly only with cabinets of the same kind, temperature, shape, duty and size.The same.

Who needs to see the stock?

A glass door earns its place when someone needs to see the stock before the door opens. In front of customers, that is the point of a display cabinet: it is built for customers to see and take what they buy, and it is lit to show the stock. Behind the counter, a glass door lets staff see what is there and how much is left without opening up.

Every opening lets warm air in, and the cabinet has to remove that heat again, so keep openings few and short with either door. What matters is how your staff use the cabinet.

  • Glass helps where staff open doors to look for something or to check what is left. Seeing first can mean fewer and shorter openings.
  • Solid does the job where each item has a fixed place, staff open the door only to take what they know is there, and nobody else needs to see in.
  • Door habits matter with either. Decide what you need, open, take it and close. A door left ajar still lets warm air in, and in humid weather, moisture with it.

For an open display against a glass-door display, see the guide to open multideck or glass-door display refrigeration.

Where will the cabinet stand?

Where the cabinet stands matters as much as the door. Keep any cabinet out of direct sun, away from ovens, cookers and other heat, and out of warm draughts from doorways, fans and air conditioning. Sun and heat on a cabinet make it work harder to hold temperature, and use more energy doing it.

Where the cabinet stands and what to weigh
Where it standsWhat to weigh
Where customers choose, in a shop, cafe or barA display cabinet, with glass doors and lights. Check that its temperature class suits what it will hold, and its climate class suits the room.
A kitchen line or preparation areaHeat. A busy kitchen can run above 30°C, the test room for a normal-duty cabinet.
Behind a counter, in sight of customersGlass shows the stock, and the state of the shelves, to anyone at the counter. A solid door keeps back-of-house stock out of view.
By a window, an outside door or a wall that takes the sunSun and warm draughts. Move the cabinet if you can. Glass lets more of that heat through than a solid door.
A humid roomSweat on the glass. Compare how warm and humid the room gets with the cabinet's climate class, and read the section on condensation below.

Lighting

A glass-door cabinet is usually lit inside so the stock shows. Lights use power, so ask whether they are LED and whether they can be dimmed or switched off after hours. Some cabinets switch their lights on and off with use, or dim them until someone comes near. On some solid-door cabinets the light comes on only when the door opens. Some products are sensitive to ultraviolet light, so before you show them unwrapped behind lit glass, check the product maker's storage instructions.

Will a glass door cope with the heat?

Glass lets more heat through than a solid door, which is why glass doors on commercial cabinets are double or triple glazed, often with a heat-reflective low-e coating. Even so, the glass-door version of a cabinet can be rated for less heat than its solid-door twin. On matching pairs from two makers, each pair the same size inside:

  • one maker rates its two-door underbench fridge to climate class 5, heavy duty, with solid doors, and to class 4, normal duty, with glass doors
  • the other rates both versions of its underbench fridge to class 4, but gives a maximum room temperature of 38°C with solid doors and 32°C with glass.

That is two pairs, not a rule, so check the duty class and the maximum room temperature for the exact model. The federal energy rules for commercial cabinets, the Greenhouse and Energy Minimum Standards (Refrigerated Cabinets) Determination 2024 (opens in a new tab), test cabinets in three rooms, from class 3 at 25°C to class 5 at 40°C. Check the class and the maker's maximum room temperature against the hottest your room gets. The guide to commercial fridge climate classes sets the rooms out and says what to ask a supplier.

Will a glass door fog up in a humid room?

It can. Glass is a poorer insulator, so in warm, humid air the outside of the glass can fall below the dew point and sweat. The inner pane can fog during or just after an opening and then clear. Glass doors are built to resist this with double or triple glazing and, on some models, a heater in the glass or the frame.

  • A heater keeps glass clear, and uses power. Heater controls can turn the heating down when the air is drier. On one range of glass doors, the door built for humid, tropical shops cost the most to run.
  • Freezer glass has more to do. A glass freezer door is usually triple glazed where a fridge door is double, and takes more heater power to stay clear.
  • Match the cabinet to the room. Display cabinets are tested at 25°C and 60% humidity, and some are designed for air-conditioned shops kept at 55% humidity or less. A room warmer or more humid than the cabinet's class can make the glass sweat.
  • Sweat that keeps coming back in one place, ice on a door frame, or water on the floor below is worth recording.

If a cabinet or coolroom door already sweats, the guide to coldroom condensation and frost shows what to record before you call.

Is glass harder to keep clean?

Both doors take routine cleaning, and the manual for each model says how. The difference is what shows.

  • Glass presents the stock on a display cabinet, so marks and smears are on show. The usual cleaning is warm water and a soft cloth or sponge, dried with a soft cloth, with no abrasive or corrosive cleaners.
  • Stainless steel shows finger marks too. A damp cloth takes off light marks, day-to-day cleaning is a soft cloth and soapy water, and where the polishing grain shows, you wipe with the grain. Cleaners containing chloride, and hypochlorite bleach, damage it.
  • Door seals on either door need to be clean so the door closes fully. A door that does not close lets warm, moist air in, and the stock warms up.
  • Keep stock clear of the door. Stock that hangs over a shelf edge can stop a door shutting or break the glass.
  • Broken glass near food. Safe Food Australia (opens in a new tab), the guide to the food safety standards, says that if glass breaks near exposed food, it would be reasonable to suspect the food could be contaminated with glass.

Keep water away from the cabinet's electrics, and leave anything behind a grille or panel to a technician. The guide to cleaning commercial refrigeration covers what staff can clean and what to leave.

How do you compare energy figures fairly?

Commercial fridges and freezers covered by the GEMS (Refrigerated Cabinets) Determination 2024 (opens in a new tab) have to meet minimum energy performance standards. An energy label is not required, and where a seller shows a star rating, the stars have to be worked out the determination's way. Each covered model has a tested daily energy figure, in kWh per 24 hours, and that is the number to compare.

The door does not decide how a cabinet is tested. What it is built for does. A glass-door storage fridge and a solid-door storage fridge of the same duty are tested the same way, so their figures compare. A glass-door display fridge is tested another way, so its figure does not line up with a storage fridge's. The guide to comparing commercial fridge energy ratings and running costs sets out how each kind is tested and what has to match before two figures compare.

What one matching pair shows

On one maker's two-door underbench fridges, both 202 litres net, the energy figures come from the same 30°C test room, so they compare. The solid-door version is rated heavy duty and its figure is 1.86 kWh a day. The glass-door version is rated normal duty, its figure is 2.39 kWh a day, and it gives off a little more heat into the room. That is one pair. The tested figure also comes from a standard test, not from the way your staff use the door. Compare the figures for the exact models you are choosing between, and think about how the door will be used.

Reading the label or the specification sheet

What a commercial fridge label or specification sheet tells you
What you seeWhat it tells you
Display or storageWhat the cabinet was built and tested for.
A class such as 4M1The climate class it was tested in, then how cold it kept its test packs. See the guide to commercial fridge climate classes.
Energy consumption, kWh per 24 hoursThe tested daily figure. Multiply it by 365 for a rough yearly figure.
Star rating, if shownOptional. It rates the cabinet against a reference for its own product class, so stars do not compare a display cabinet with a storage cabinet.
A second climate class, or a maximum room temperatureSome sheets give an electrical safety climate class or a maximum room temperature as well as the tested class. Where they differ, the label and the manual for the model decide where it can stand.

Potentially hazardous chilled food is kept at 5°C or below, unless the business can show another temperature is safe, and frozen food stays frozen, as Food Standards Australia New Zealand's guides to the food safety standards (opens in a new tab) and storing food safely (opens in a new tab) explain. Storage cabinets for chilled food are tested to M1, so for food in a display cabinet, look for M1 or colder (M0) as well. For running costs, see the guide to comparing commercial refrigeration energy ratings.

Common questions

Does a glass-door fridge use more power than a solid-door fridge?

The door alone does not tell you. Glass lets more heat through, and glass-door cabinets are usually lit and sometimes heated, which can push the figure up. A glass door can also mean fewer, shorter openings where staff look for stock. Compare the tested daily figures of models of the same kind, temperature, shape, duty and size.

Can a glass-door fridge be used for food storage in a kitchen?

Yes. A storage cabinet can have glass doors, and storage cabinets for chilled food are tested to M1. Check its duty class or maximum room temperature against the hottest your kitchen gets, because a glass-door version can be rated for less heat than a solid-door one.

Can I keep food in a glass-door drinks fridge?

Check what it is registered as first. A refrigerated drinks cabinet is built for non-perishable drinks only, and is tested to M2, which allows its test packs up to 7°C. It is not built for potentially hazardous food.

Should a back-of-house fridge have a glass door?

Where staff open doors to look for stock or check what is left, a glass door can help. Where the cabinet sits on a hot kitchen line, in the sun or in a humid area, a solid door is the safer place to start.

Glass or solid door comparison sheet

Glass or solid door comparison sheet

Fill in the job and the room first, then up to two candidates, with the figures from each model's specification sheet. Compare the energy figures only where the like-for-like checks at the end are a yes.

Your answers stay on this open page. They are not saved or sent. Copy or print them before you leave.

The job

Who opens it
Temperature

Where it will stand

Humidity in the room
Air-conditioned
Direct sun on the cabinet
Lighting inside the cabinet

Door use

Main reason staff open it

Candidate A

Candidate A: door

Candidate B

Candidate B: door

Like for like

Same kind, temperature and shape
Same duty class, for storage cabinets
Figures taken from each specification sheet

What to bring us

ABL supplies commercial refrigeration equipment. Bring the comparison sheet when you ask about a cabinet, or read it out when you call: the room, the door use and the figures tell us what the cabinet has to do. The equipment supply page explains how to enquire. If a cabinet you already have sweats, struggles in the heat or will not hold its temperature, see commercial refrigeration repairs.

Sources (25)

Checked on 19 November 2026

Choosing between glass and solid doors?

Send ABL your comparison sheet with an enquiry, or call and talk it through.

Filled in the record? Copy or print it first: it is not sent with a call or an enquiry.