Food freezing in a commercial fridge or coolroom: what to record before you call
Why chilled stock freezes in a commercial fridge or coolroom, what to check without touching the settings, and an observation sheet for the technician.
Last updated
When chilled stock freezes in a commercial fridge or coolroom, the usual causes are stock sitting in the cold air from the fan, shelves packed too tight for air to move, a setting colder than the stock needs, or a fault in the control or its sensor. A large load of very cold stock or a cold room around the equipment can do it too. Several of these look the same from outside, and the display can read normal while food freezes, because it shows the temperature at its own sensor, not in the food. So record which products froze and where they sat, take probe readings against the display, and note when it happens and what changed. Leave the setting as it is for the technician. What happens to the food that froze is your business's decision.
How to use this guide
Step 1: Note where it froze
Which products, which shelf, and how close to the cold air.
Go to Where it frozeStep 2: Fill in the sheet
Probe readings against the display, the timing and what changed.
Go to the record
Commercial fridge troubleshooting: freezing, frost or too warm?
Food freezing in chilled storage is a fault of its own. It is not the same as frost on the equipment, and it is not the same as a cabinet that will not get cold enough. Start from what you can see.
| What you see | Where to start |
|---|---|
| Chilled stock is frozen, icy or full of ice crystals | This guide. |
| Frost or ice on the coil, the fan guard, the door frame, the walls or the floor | That is frost on the equipment, a different fault. See the guide to coldroom condensation and frost. |
| Stock or the display is too warm, or slow to come back after the door opens | See the commercial refrigeration repairs page and the guide to coolroom temperature recovery. |
| Frozen in one spot and too warm in another | This guide, and probe the warm stock too. When air cannot move evenly, some stock over-cools while other stock runs warm. |
| A code or an alarm on the display | Codes differ between models. See the guide to commercial fridge alarms, and record the code on the sheet below. |
| It comes and goes, and is gone when anyone looks | See the guide to recording intermittent refrigeration faults. |
Why does a commercial fridge freeze food?
The air leaving the evaporator, the cold coil and its fan, is colder than the air the rest of the stock sits in. Anything that keeps food in that cold air, or makes the whole cabinet or room run colder, can freeze it. These are the usual causes.
| Possible cause | What you might notice | Who looks into it |
|---|---|---|
| Stock in the cold air stream | Items right against or in front of the air outlet, the fan, the air slots or, in a coolroom, stacked up close under the evaporator freeze, while stock further away does not. | You can see it. Note where the stock sat before you move it. |
| Shelves packed too tight | Shelves full to the edges, items touching each other or the walls, or the air slots covered. Air cannot move evenly, so some stock over-cools and some runs warm. | You can see it. Note how full it was. |
| A large load of very cold or frozen stock | Freezing after a delivery of very cold stock, or after frozen stock went in to thaw. The cabinet usually comes back to its normal temperature once that load has settled. | You can note it. If the temperature does not come back, call. |
| Cold surroundings | Worse on cold nights or in winter, or in a coolroom along a wall shared with a freezer room or a cold outside wall. A room that is too cold can make some display cabinets over-cool, and some chillers show a message when the room gets too cold. | You can note the room temperature. The technician looks at the rest. |
| A setting colder than the stock needs | Stock freezes throughout, not just in one spot. The setting may have been changed, or it may not suit what the cabinet holds now. | The technician. Leave the setting as it is. |
| A control or sensor fault | The food probes much colder than the display. The sensor may be reading warmer air than where the food sits, it may have failed, or the control may be faulty. Some controllers show a code when a sensor fails. | The technician. |
| In a coolroom, a fan or coil problem | Freezing near one evaporator in a room with more than one, or a fan that has stopped. A dirty coil, a stopped fan or one evaporator not working properly can make the air leaving the others colder. | The technician. |
These are possibilities, not a diagnosis. More than one can be at work at the same time, and which one applies to your cabinet or room is for the technician to find on site. The manual for your model lists its own causes and codes.
Where did it freeze, and what froze?
Before you move anything, note what froze and where it sat. A photo of the shelf does the same job in seconds. The pattern helps the technician: freezing in one spot and freezing throughout lead to different checks.
- The products: what they are, how many items, and how frozen: a few ice crystals, frozen at the edges, or frozen hard.
- The batch: the delivery date, batch or use-by date of each affected product, so your business can find all of the affected stock.
- The shelf and the spot: top, middle or bottom, front or back, left or right, and how close it was to the air outlet, the fan, the air slots or a wall.
- What was around it: whether the shelf was packed tight, and whether the item touched other stock or the wall.
- Containers: any bottle, jar or container that cracked or split as it froze.
- Whether it repeats: whether the same spot freezes again with new stock in it, or whether other spots start to freeze.
- On a prep counter: whether the frozen items were in the top rail or the cabinet below, and whether they sat in the rail overnight. On some prep counters, depending on conditions, ingredients left in the rail for long periods such as overnight can freeze.
In a coolroom, note which rack or shelf, and how far the stock sat from the evaporator. The guide to organising commercial cold storage covers the space the air needs around the evaporator and the walls.
What does the display show, and what does the food read?
The display shows the temperature where the cabinet's own sensor sits, which is not necessarily the temperature of the food. That is how a display can read normal while stock near the air outlet freezes. Check the food itself with a probe thermometer. Under Standard 3.2.2, a food business that handles potentially hazardous food must have a thermometer that measures food temperature accurately to plus or minus 1°C, as Safe Food Australia (opens in a new tab) explains.
| Reading | How to take it | Why it helps |
|---|---|---|
| The display | Write down what it shows, with the time, at the same moment as your probe readings. | The technician compares it with the food. |
| A probe in an item that froze | If the probe will not go in, place it between two frozen packages. Wait for the reading to settle. | Shows how cold that spot gets. |
| A probe in stock elsewhere | Probe stock at the other end of the same shelf and on another shelf, in the thickest part, or along and between packages for packaged food. | Shows whether one spot is too cold or the whole cabinet is. Temperatures inside a cabinet or room vary. |
| The setting | Only if you can find it without pressing buttons or opening a menu, such as in your own records or the last service report. Otherwise leave it blank. | The technician checks it against what you store. |
| The room | A thermometer in the air where the cabinet stands. | A room that is too cold can make some display cabinets over-cool. |
| A code or message | Copy it exactly as it shows. | Codes differ between models. See the guide to commercial fridge alarms. |
Take at least two sets of readings at different times, such as at opening and in the afternoon, and write each one down as you take it. Leave a gap where no reading was taken. Keep the thermometer clean and in good condition, and have it calibrated as your food safety procedure says.
For why the display and the food read differently, see the guide to food temperature and fridge readings. A temperature monitoring system can log readings for you, and can watch the coldest spot as well as the warmest.
The equipment, and the conditions it runs in
- The nameplate: the brand, model and serial number. The manual for your model shows where the plate is.
- What kind of equipment: a storage cabinet, a display cabinet, a prep counter or a walk-in coolroom, and what it is meant to hold.
- Its rating: the room conditions it is made for, from its label or its manual.
- Where it stands: the room, how cold that room gets overnight and in winter, and whether a coolroom wall is shared with a freezer room or faces outside.
- The last service: when it was, and what was done. Keep the service report handy if you have it.
Then write down anything that changed before the freezing started, with its date, so the technician can line it up with the first frozen stock:
- a new or moved cabinet, or a new stock layout
- a new product line, or the cabinet now holding something different
- a delivery of very cold or frozen stock, or frozen stock put in to thaw
- colder weather, or the heating in the room turned off
- a service, a repair or a new controller
- anyone pressing buttons on the controller
What you can check safely, and what to leave
These checks need no tools and open nothing. Look, write down what you see, and call.
- Look at whether stock sits against or in front of the air outlet, the fan, the air slots or the coil.
- Look at whether the shelves are packed so tight that air cannot move between the items.
- Take probe readings, and the display reading at the same time.
- Note the air temperature in the room where the cabinet stands.
- In a coolroom, look from the floor at whether each evaporator's fans are turning. Do not reach in or climb up to them.
- Once you have noted where it sat, keep stock clear of the air outlet, the fan and the air slots, with space around each item.
Do not change the setting, even if it looks too cold. Some controllers are meant to be adjusted only by a service agent, and the technician needs to see what it was set to. Do not press buttons to open menus or clear a code. Do not move or cover the sensor, and do not block an air outlet with cardboard, foil or stock. Do not switch the equipment off and on to see whether the freezing stops. Do not defrost it or open covers to look inside.
What we do on a visit
We start from your sheet: what froze, where it sat, the probe readings against the display, and what changed. Then we look at the loading and the path of the air, the setting and how far the temperature is allowed to swing, the sensor and where it sits, and the fans and coils, on each evaporator in a coolroom. We find the cause before anything is changed, then tell you what we found and what the repair involves.
These checks mean reading the controller's settings and working inside the equipment, so they are for a technician. Controllers and sensors differ from model to model, and the manual for the model governs.
What about the food that froze?
Decisions about the food stay with your business and its food safety procedure. We can tell you what we find in the equipment. Whether the stock can be used, sold or thrown out is your call, not ours.
Freezing can damage food that is meant to be chilled. Fresh vegetables can suffer freezing injury, even hardy ones such as broccoli. Bottles and jars can crack or break as they freeze, which brings a risk of injury and of contaminating other food. Safe Food Australia (opens in a new tab) says businesses should be guided by the manufacturer's storage instructions, so note what the label of each affected product says.
Freezing is not the only reading to watch. A cabinet that over-cools in one spot can be too warm in another, so probe the rest of the stock as well. Under Standard 3.2.2, as Safe Food Australia (opens in a new tab) explains it, potentially hazardous food is kept at 5°C or below or at 60°C or above, unless the business can show that another temperature is safe, and frozen food stays frozen. If anything probes above 5°C, the commercial refrigeration repairs page sets out the food safety points for stock when refrigeration fails.
The sheet on this page is for the technician. It does not replace your food safety records. For those, see the guide to commercial refrigeration temperature records.
Over-cooling observation sheet
How urgent is it?
| What you see | What to do |
|---|---|
| Any stock in the same cabinet or room probes above 5°C | Your food safety procedure decides what happens to that food, and the repairs page sets out the food safety points it rests on. Then call. |
| A code, an alarm or a sensor message on the display | Write it down exactly as it shows, and call. A failed sensor is a service call. |
| Stock freezing throughout, or more of it each day | Book a visit. Keep stock clear of the air outlets, and keep writing down readings. |
| Freezing in one spot that stopped once the stock was clear of the cold air | Keep it clear and take a reading or two over the next days. If it starts again, or other spots freeze, book a visit. |
| Freezing only after a delivery of very cold or frozen stock | Note it on the sheet. If the cabinet does not come back to its normal temperature once that load has settled, book a visit. |
| Bottles, jars or containers cracked | Your food safety procedure decides what happens to the food around them. Note it on the sheet. |
A sign that looks minor can still come from a fault, so if you are unsure, call.
ABL repairs walk-in coolrooms, freezer rooms, display fridges and commercial kitchen refrigeration. The commercial refrigeration repairs page explains how to book. Have the observation sheet in front of you when you call.
Sources (14)
Checked on 19 November 2026
- Food Standards Australia New Zealand: thermometers, updated 1 October 2025 (opens in a new tab)
- Food Standards Australia New Zealand: Safe Food Australia, chapter on Standard 3.2.2, file revised April 2026 (opens in a new tab)
- Food Standards Australia New Zealand: storing food safely, updated 1 October 2025 (opens in a new tab)
- Ontario Ministry of Agriculture, Food and Agribusiness: troubleshooting cold storage problems, December 2024 (opens in a new tab)
- Hoshizaki America: Steelheart refrigerated prep table instruction manual, August 2020 (opens in a new tab)
- Bromic Refrigeration: underbench fridges instruction manual, June 2022 (opens in a new tab)
- Bromic Refrigeration: semi vertical and full height multideck instruction manual, June 2025 (opens in a new tab)
- Traulsen: C Series reach-in refrigerators and freezers owner's manual, 2026 (opens in a new tab)
- SKOPE: TME and SKT ActiveCore top mount vertical chiller user manual, April 2017 (opens in a new tab)
- Williams Refrigeration Australia: operating manual for upright and counter refrigeration, April 2020 (opens in a new tab)
- KPS Global: walk-in organization tips, October 2018 (opens in a new tab)
- Danfoss: cold room troubleshooting and fault diagnosis (opens in a new tab)
- Postharvest Management of Vegetables: cooling methods (opens in a new tab)
- ABL Refrigeration: commercial refrigeration services (opens in a new tab) ABL's own page.
Related pages
- Coldroom condensation and frost: an observation guide
If the ice is on the equipment rather than in the food.
- Food temperature and fridge readings: understanding the difference
Why the display can read normal while food freezes.
- Organising commercial cold storage for stock access and food protection
The space the air needs around the evaporator and the stock.
Food freezing in a fridge or coolroom?
Call ABL or send an enquiry, and have the observation sheet, the brand and model, and your probe readings ready.